Skip to content
Lieven Hollevoet edited this page Sep 22, 2014 · 1 revision

From Dickie Bradford on the mailing list:

TI103 Setup

These are the settings I have used to setup the TI103, YMMV, But it works for me. :-) image:misterhouse/act-TI103-RS232_1.jpg

TI103 make sure you get a working one ! , mine was bad from the vendor and they would not exchange ...:( by Gpski

Please note some important information from the maker of the ti103 driver that I found on yahoo groups:

Driver Reliability ti103

While the external interface is otherwise identical, internally TI103.pm is substantially different. The ACT TI-103 accepts ASCII commands strings and TI103.pm in essence functions as a protocol translator. I believe that all of the commands that Misterhouse sends are implemented. But my collection of X10 modules is fairly limited. Only those commands that have meaning for the modules I have are tested. I have no 2way modules so while status commands and receiving are implemented, it is somewhere between likely and certain that they will not work - or atleast they will not return the correct data.

ACT's addressing beyond 255 units is not implemented.

For reference purposes I have a cm11. The TI-103 driver was done for a friend, as part of a Misterhouse based Radiant Heat control system I am working on. Thus far while the TI-103 has performed well I have not noticed any advantage over the cm11.

TI103 Jumper Settings


1 - OFF 2 - OFF 3 - OFF 4 - OFF 5 - OFF 6 - OFF 7 - ON North america 60 hz 1 phase 8 - ON setup for 19200 baud as perl code is only setup for this speed

Put following lines in the file mh/code/ mh.private.ini


    • Linux:**
ti103_port=/dev/ttyS1
    • Windows:**
ti103 = COM1 ti103_baudrate = 19200

Put following line in the file mh/code/ lights.mht


X10A, P2, Ceiling_Light, MasterBedroom, TI103, AM486

The LAST Step:


This shows the start log of a properly configured mr house - ignore the orion III

Notice the line: " - Creating ti103 port on COM1" [5th] thats what you want to see happen to get the ti103 running with MrHouse.

image:misterhouse/mh2.JPG width="800" height="449"

This is how the command window looks with serial and x10 debug on with the ti103:

Notice the command lines that are produced by MrHouse PERL ......

    • X10 : interface=ti103 isfunc=1/0 save_unit-XFF data=XFM/XFF**
This is how an x 10 command sent across the **TI103** powerline interface to selected a unit looks.

//This permits you to actually view your output to the powerline module for debugging!// A line is likewise sent every minute by default on this MrHouse setup. ( all those saving object states without command lines)

This is the normal polling action MrHouse runs every minute for updates to your main program computer.

If you also had a diffrent x10 device the line would start with that devices name. image:misterhouse/mh1run.JPG caption="win xp 64 bit mr house ti103 interface operating correctly .."

Clone this wiki locally