Skip to content

Items Zmtrigger_Item

ggodart edited this page Jan 6, 2021 · 1 revision

Zmtrigger_Item

See original

SYNOPSIS

  use Zmtrigger_Item;

  $name_for_camera = new Zmtrigger_Item("Numeric_ID_of_monitor_in_ZoneMinder");
  $camera2 = new Zmtrigger_Item(2,10,200,"Second monitor triggered for 10s with a score of 200");

  set $name_for_camera ON;  # Starts alarm condition in ZoneMinder
  set $name_for_camera OFF;  # Cancells alarm condition in ZoneMinder

  $motionSensor->tie_items($camera2) if state_now $alarm ON;

DESCRIPTION

Object used to trigger ZoneMinder events

Creates an item based on the Generic_Item. The item connects to your ZoneMinder server utilizing a Socket_Item and the zmtrigger package included in ZoneMinder.

SETUP In ZoneMinder click "Options"

Select the "System" tab

Check the box to enable OPT_TRIGGERS

edit /opt/zm/bin/zmtrigger.pl

in the "Channel/Connection Modules" section comment all lines starting with push except the one referencing

  ZoneMinder::Trigger::Channel::Inet

Restart ZoneMinder

INHERITS

Generic_Item

METHODS

Method Description
new($monitor_id,$max_duration,$score,$description) Creates a new Zmtrigger_Item.
$monitor_id should be a valid numeric ZoneMinder monitor ID
$max_duration OPTIONAL Specifies the maximum duration of the trigger. If not specified the value specified in mh.private.ini under zm_trigger_max_duration will be used.
$score OPTIONAL Specifies the default score of the trigger. If not specified the value specified in mh.private.ini under zm_trigger_score will be used.
$description OPTIONAL Specifies the default description of the trigger to be displayed in Zoneminder. If not specified the value specified in mh.private.ini under zm_trigger_description will be used
set($state) The set method changes the state of an existing Zmtrigger_Item by creating a Socket_Item which connects via telnet to the zmtrigger.pl provided with ZoneMinder.
$state: Should only be ON or OFF - ON creates an event trigger with a maximum duration. In case of a communication failure or MH crash the trigger will time out on the ZoneMinder end. - OFF cancels the active trigger for the monitor.

INI PARAMETERS

  # Category = Zmtrigger
  #
  #
  # Socket_Item properties
  #
  # IP or Host name of server running ZoneMinder
  zm_server_address = localhost
  # Port assigned to ZoneMinder's zmtrigger
  zm_server_port = 6802
  #
  # Zmtrigger_Item Default Values
  #
  # Maximum duration of triggered state in seconds if not cancelled by an OFF
  zm_trigger_max_duration = 300
  # Score assigned to the trigger in ZoneMinder
  zm_trigger_score = 200
  # Description of trigger passed to ZoneMinder
  zm_trigger_description = MisterHouse

AUTHOR

Dustin Robinson

SEE ALSO

Clone this wiki locally