Original file line number Diff line number Diff line change
Expand Up @@ -21,9 +21,9 @@ agent.monitoring:
logs: true
# enables metrics monitoring
metrics: true
# exposes /debug/pprof/ endpoints
# exposes /debug/pprof/ endpoints for agent and beats
michel-laterman marked this conversation as resolved.
Show resolved Hide resolved
# enable these endpoints if the monitoring endpoint is set to localhost
pprof: true
pprof: false
# specifies output to be used
use_output: monitoring
----
Expand All @@ -37,7 +37,8 @@ To enable monitoring, set `agent.monitoring.enabled` to `true`. Also set the
collected. If neither setting is specified, monitoring is turned off. Set
`use_output` to specify the output to which monitoring events are sent.

The `agent.monitoring.pprof` option controls whether the {agent} exposes the
`/debug/pprof/` endpoints with the monitoring endpoints. It is set to `true`
by default. If the monitoring endpoint is accessible over a network (not recommended),
set this option to `false` to disable the `/debug/pprof/` endpoints.
The `agent.monitoring.pprof` option controls whether the {agent} and {beats} exposes the
michel-laterman marked this conversation as resolved.
Show resolved Hide resolved
`/debug/pprof/` endpoints with the monitoring endpoints. It is set to `false`
by default. Data produced by these endpoints can be useful for debugging but present a
security risk. It is reccomended that this option remains `false` if the monitoring endpoint
is accessible over a network.
michel-laterman marked this conversation as resolved.