Stratified tank bugfix #1849

Merged
merged 3 commits into from
Oct 4, 2024
Merged
Show file tree
Hide file tree
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
1 change: 1 addition & 0 deletions Changelog.md
Original file line number Diff line number Diff line change
Expand Up @@ -42,6 +42,7 @@ __Bugfixes__
- Fixes utility bill calculations if there is battery storage or a generator.
- BuildResidentialScheduleFile measure: Fixes possible divide by zero error during generation of stochastic clothes washer and dishwasher schedules.
- Allows negative values for `Building/Site/Elevation`.
- Fixes lower element height for a water heater using the advanced `WaterHeatingSystem/extension/TankModelType=stratified`.

## OpenStudio-HPXML v1.8.1

Expand Down
6 changes: 3 additions & 3 deletions HPXMLtoOpenStudio/measure.xml
Original file line number Diff line number Diff line change
Expand Up @@ -3,8 +3,8 @@
<schema_version>3.1</schema_version>
<name>hpxm_lto_openstudio</name>
<uid>b1543b30-9465-45ff-ba04-1d1f85e763bc</uid>
<version_id>56ae4bc1-86cd-4cad-aeb2-5b3670066114</version_id>
<version_modified>2024-10-01T18:47:17Z</version_modified>
<version_id>2ecbdcc0-d0e3-4c8f-b8f8-a839e9bdbee1</version_id>
<version_modified>2024-10-04T17:02:56Z</version_modified>
<xml_checksum>D8922A73</xml_checksum>
<class_name>HPXMLtoOpenStudio</class_name>
<display_name>HPXML to OpenStudio Translator</display_name>
Expand Down Expand Up @@ -627,7 +627,7 @@
<filename>waterheater.rb</filename>
<filetype>rb</filetype>
<usage_type>resource</usage_type>
<checksum>7E9EBE10</checksum>
<checksum>1E7D40B1</checksum>
</file>
<file>
<filename>weather.rb</filename>
Expand Down
46 changes: 18 additions & 28 deletions HPXMLtoOpenStudio/resources/waterheater.rb
Original file line number Diff line number Diff line change
Expand Up @@ -146,8 +146,6 @@ def self.apply_heatpump(model, runner, spaces, hpxml_bldg, hpxml_header, water_h
t_set_c = get_t_set_c(water_heating_system.temperature, water_heating_system.water_heater_type)
loop = create_new_loop(model, t_set_c, hpxml_header.eri_calculation_version, unit_multiplier)

h_tank = 0.0188 * water_heating_system.tank_volume + 0.0935 # Linear relationship that gets GE height at 50 gal and AO Smith height at 80 gal

# Add in schedules for Tamb, RHamb, and the compressor
hpwh_tamb = Model.add_schedule_constant(
model,
Expand Down Expand Up @@ -203,7 +201,7 @@ def self.apply_heatpump(model, runner, spaces, hpxml_bldg, hpxml_header, water_h
coil = setup_hpwh_dxcoil(model, runner, water_heating_system, hpxml_bldg.elevation, obj_name, airflow_rate, unit_multiplier)

# WaterHeater:Stratified
tank = setup_hpwh_stratified_tank(model, water_heating_system, obj_name, h_tank, solar_fraction, hpwh_tamb, bottom_element_sp, top_element_sp, unit_multiplier, hpxml_bldg.building_construction.number_of_bedrooms)
tank = setup_hpwh_stratified_tank(model, water_heating_system, obj_name, solar_fraction, hpwh_tamb, bottom_element_sp, top_element_sp, unit_multiplier, hpxml_bldg.building_construction.number_of_bedrooms)
loop.addSupplyBranchForComponent(tank)

add_desuperheater(model, runner, water_heating_system, tank, loc_space, loc_schedule, loop, unit_multiplier)
Expand All @@ -221,7 +219,7 @@ def self.apply_heatpump(model, runner, spaces, hpxml_bldg, hpxml_header, water_h
fan.additionalProperties.setFeature('ObjectType', Constants::ObjectTypeWaterHeater) # Used by reporting measure

# WaterHeater:HeatPump:WrappedCondenser
hpwh = setup_hpwh_wrapped_condenser(model, obj_name, coil, tank, fan, h_tank, airflow_rate, hpwh_tamb, hpwh_rhamb, min_temp, max_temp, control_setpoint_schedule, unit_multiplier)
hpwh = setup_hpwh_wrapped_condenser(model, obj_name, coil, tank, fan, airflow_rate, hpwh_tamb, hpwh_rhamb, min_temp, max_temp, control_setpoint_schedule, unit_multiplier)

# Amb temp & RH sensors, temp sensor shared across programs
amb_temp_sensor, amb_rh_sensors = get_loc_temp_rh_sensors(model, obj_name, loc_space, loc_schedule, conditioned_zone)
Expand Down Expand Up @@ -901,7 +899,6 @@ def self.apply_solar_thermal(model, spaces, hpxml_bldg, plantloop_map)
# @param coil [TODO] TODO
# @param tank [TODO] TODO
# @param fan [TODO] TODO
# @param h_tank [TODO] TODO
# @param airflow_rate [TODO] TODO
# @param hpwh_tamb [TODO] TODO
# @param hpwh_rhamb [TODO] TODO
Expand All @@ -910,17 +907,12 @@ def self.apply_solar_thermal(model, spaces, hpxml_bldg, plantloop_map)
# @param setpoint_schedule [TODO] TODO
# @param unit_multiplier [Integer] Number of similar dwelling units
# @return [TODO] TODO
def self.setup_hpwh_wrapped_condenser(model, obj_name, coil, tank, fan, h_tank, airflow_rate, hpwh_tamb, hpwh_rhamb, min_temp, max_temp, setpoint_schedule, unit_multiplier)
h_condtop = (1.0 - (5.5 / 12.0)) * h_tank # in the 6th node of the tank (counting from top)
h_condbot = 0.01 * unit_multiplier # bottom node
h_hpctrl_up = (1.0 - (2.5 / 12.0)) * h_tank # in the 3rd node of the tank
h_hpctrl_low = (1.0 - (8.5 / 12.0)) * h_tank # in the 9th node of the tank

def self.setup_hpwh_wrapped_condenser(model, obj_name, coil, tank, fan, airflow_rate, hpwh_tamb, hpwh_rhamb, min_temp, max_temp, setpoint_schedule, unit_multiplier)
hpwh = OpenStudio::Model::WaterHeaterHeatPumpWrappedCondenser.new(model, coil, tank, fan, setpoint_schedule, model.alwaysOnDiscreteSchedule)
hpwh.setName("#{obj_name} hpwh")
hpwh.setDeadBandTemperatureDifference(3.89)
hpwh.setCondenserBottomLocation(h_condbot)
hpwh.setCondenserTopLocation(h_condtop)
hpwh.setCondenserBottomLocation((1.0 - (12 - 0.5) / 12.0) * tank.tankHeight.get) # in the 12th node of a 12-node tank (counting from top)
hpwh.setCondenserTopLocation((1.0 - (6 - 0.5) / 12.0) * tank.tankHeight.get) # in the 6th node of a 12-node tank (counting from top)
hpwh.setEvaporatorAirFlowRate(UnitConversions.convert(airflow_rate * unit_multiplier, 'ft^3/min', 'm^3/s'))
hpwh.setInletAirConfiguration('Schedule')
hpwh.setInletAirTemperatureSchedule(hpwh_tamb)
Expand All @@ -934,9 +926,9 @@ def self.setup_hpwh_wrapped_condenser(model, obj_name, coil, tank, fan, h_tank,
hpwh.setOffCycleParasiticElectricLoad(0)
hpwh.setParasiticHeatRejectionLocation('Outdoors')
hpwh.setTankElementControlLogic('MutuallyExclusive')
hpwh.setControlSensor1HeightInStratifiedTank(h_hpctrl_up)
hpwh.setControlSensor1HeightInStratifiedTank((1.0 - (3 - 0.5) / 12.0) * tank.tankHeight.get) # in the 3rd node of a 12-node tank (counting from top)
hpwh.setControlSensor1Weight(0.75)
hpwh.setControlSensor2HeightInStratifiedTank(h_hpctrl_low)
hpwh.setControlSensor2HeightInStratifiedTank((1.0 - (9 - 0.5) / 12.0) * tank.tankHeight.get) # in the 9th node of a 12-node tank (counting from top)

return hpwh
end
Expand Down Expand Up @@ -1023,15 +1015,16 @@ def self.setup_hpwh_dxcoil(model, runner, water_heating_system, elevation, obj_n
# @param model [OpenStudio::Model::Model] OpenStudio Model object
# @param water_heating_system [HPXML::WaterHeatingSystem] The HPXML water heating system of interest
# @param obj_name [String] Name for the OpenStudio object
# @param h_tank [TODO] TODO
# @param solar_fraction [TODO] TODO
# @param hpwh_tamb [TODO] TODO
# @param hpwh_bottom_element_sp [TODO] TODO
# @param hpwh_top_element_sp [TODO] TODO
# @param unit_multiplier [Integer] Number of similar dwelling units
# @param nbeds [Integer] Number of bedrooms in the dwelling unit
# @return [TODO] TODO
def self.setup_hpwh_stratified_tank(model, water_heating_system, obj_name, h_tank, solar_fraction, hpwh_tamb, hpwh_bottom_element_sp, hpwh_top_element_sp, unit_multiplier, nbeds)
def self.setup_hpwh_stratified_tank(model, water_heating_system, obj_name, solar_fraction, hpwh_tamb, hpwh_bottom_element_sp, hpwh_top_element_sp, unit_multiplier, nbeds)
h_tank = 0.0188 * water_heating_system.tank_volume + 0.0935 # m; Linear relationship that gets GE height at 50 gal and AO Smith height at 80 gal

# Calculate some geometry parameters for UA, the location of sensors and heat sources in the tank
v_actual = calc_storage_tank_actual_vol(water_heating_system.tank_volume, water_heating_system.fuel_type) # gal
a_tank, a_side = calc_tank_areas(v_actual, UnitConversions.convert(h_tank, 'm', 'ft')) # sqft
Expand All @@ -1054,9 +1047,6 @@ def self.setup_hpwh_stratified_tank(model, water_heating_system, obj_name, h_tan
e_cap *= unit_multiplier
parasitics *= unit_multiplier

h_UE = (1.0 - (3.5 / 12.0)) * h_tank # in the 3rd node of the tank (counting from top)
h_LE = (1.0 - (9.5 / 12.0)) * h_tank # in the 10th node of the tank (counting from top)

tank = OpenStudio::Model::WaterHeaterStratified.new(model)
tank.setName("#{obj_name} tank")
tank.setEndUseSubcategory('Domestic Hot Water')
Expand All @@ -1067,12 +1057,12 @@ def self.setup_hpwh_stratified_tank(model, water_heating_system, obj_name, h_tan
tank.heater1SetpointTemperatureSchedule.remove
tank.setHeater1SetpointTemperatureSchedule(hpwh_top_element_sp)
tank.setHeater1Capacity(UnitConversions.convert(e_cap, 'kW', 'W'))
tank.setHeater1Height(h_UE)
tank.setHeater1Height((1.0 - (3 - 0.5) / 12.0) * h_tank) # in the 3rd node of a 12-node tank (counting from top)
tank.setHeater1DeadbandTemperatureDifference(18.5)
tank.heater2SetpointTemperatureSchedule.remove
tank.setHeater2SetpointTemperatureSchedule(hpwh_bottom_element_sp)
tank.setHeater2Capacity(UnitConversions.convert(e_cap, 'kW', 'W'))
tank.setHeater2Height(h_LE)
tank.setHeater2Height((1.0 - (10 - 0.5) / 12.0) * h_tank) # in the 10th node of a 12-node tank (counting from top)
tank.setHeater2DeadbandTemperatureDifference(3.89)
tank.setHeaterFuelType(EPlus::FuelTypeElectricity)
tank.setHeaterThermalEfficiency(1.0)
Expand Down Expand Up @@ -1988,30 +1978,30 @@ def self.create_new_heater(name:, water_heating_system: nil, act_vol:, t_set_c:
act_vol *= unit_multiplier

if tank_model_type == HPXML::WaterHeaterTankModelTypeStratified
h_tank = get_tank_height() # ft
h_tank = UnitConversions.convert(get_tank_height(), 'ft', 'm')

# Add a WaterHeater:Stratified to the model
new_heater = OpenStudio::Model::WaterHeaterStratified.new(model)
new_heater.setEndUseSubcategory('Domestic Hot Water')
new_heater.setTankVolume(UnitConversions.convert(act_vol, 'gal', 'm^3'))
new_heater.setTankHeight(UnitConversions.convert(h_tank, 'ft', 'm'))
new_heater.setTankHeight(h_tank)
new_heater.setMaximumTemperatureLimit(90)
new_heater.setHeaterPriorityControl('MasterSlave')
configure_stratified_tank_setpoint_schedules(new_heater, schedules_file, t_set_c, model, runner, unavailable_periods)
new_heater.setHeater1Capacity(UnitConversions.convert(cap, 'kBtu/hr', 'W'))
new_heater.setHeater1Height(UnitConversions.convert(h_tank * 0.733333333, 'ft', 'm')) # node 4; height of upper element based on TRNSYS assumptions for an ERWH
new_heater.setHeater1Height((1.0 - (4 - 0.5) / 15) * h_tank) # in the 4th node of a 15-node tank (counting from top); height of upper element based on TRNSYS assumptions for an ERWH
new_heater.setHeater1DeadbandTemperatureDifference(5.556)
new_heater.setHeater2Capacity(UnitConversions.convert(cap, 'kBtu/hr', 'W'))
new_heater.setHeater2Height(UnitConversions.convert(h_tank * 0.733333333, 'ft', 'm')) # node 13; height of upper element based on TRNSYS assumptions for an ERWH
new_heater.setHeater2Height((1.0 - (13 - 0.5) / 15) * h_tank) # in the 13th node of a 15-node tank (counting from top); height of upper element based on TRNSYS assumptions for an ERWH
new_heater.setHeater2DeadbandTemperatureDifference(5.556)
new_heater.setHeaterThermalEfficiency(1.0)
new_heater.setNumberofNodes(12)
new_heater.setAdditionalDestratificationConductivity(0)
new_heater.setUseSideDesignFlowRate(UnitConversions.convert(act_vol, 'gal', 'm^3') / 60.1)
new_heater.setSourceSideDesignFlowRate(0)
new_heater.setSourceSideFlowControlMode('')
new_heater.setSourceSideInletHeight(0)
new_heater.setSourceSideOutletHeight(0)
new_heater.setSourceSideInletHeight((1.0 - (1 - 0.5) / 15) * h_tank) # in the 1st node of a 15-node tank (counting from top)
new_heater.setSourceSideOutletHeight((1.0 - (15 - 0.5) / 15) * h_tank) # in the 15th node of a 15-node tank (counting from top)
new_heater.setSkinLossFractiontoZone(1.0 / unit_multiplier) # Tank losses are multiplied by E+ zone multiplier, so need to compensate here
new_heater.setOffCycleFlueLossFractiontoZone(1.0 / unit_multiplier)
set_stratified_tank_ua(new_heater, u, unit_multiplier)
Expand Down
Loading