FEM-Design does not respond to the analysis settings in the .fdscript file. Despite setting the diaphragm calculation to "true" in the fdscript, in FEM-Design, it remains set to "None".
Source of the issue: In .fdscript, the diaphragm calculation parameter is not a boolean, instead it is an integer, and it can take the following values: '0'= None , '1'= Rigid membrane or '2'= Fully rigid
Issue:
FEM-Design does not respond to the analysis settings in the .fdscript file. Despite setting the diaphragm calculation to "true" in the fdscript, in FEM-Design, it remains set to "None".
https://strusoft.fogbugz.com/f/cases/131204/Diaphragm-calculation-setting-doesn-t-work-in-fdscript