;--------------------------------------------------------------------------------- ; level1 data with all frames ;---------------------------------------------------------------------------------

; detector 0

Frame number 363769 is weird = frame_counter value is to high and HV value is 70 (134 is expected) In the analysis we will exclude this frame

HV start ramping at frame number 358509 = this is +30sec

target 1 indices 363858 364045 target 2 indices 364046 364095 target 3 indices 364096 364342 target 4 indices 364343 364433

Assuming 4 sec lag at beginning of the target and 2 seconds uncertainty at the end

target 1 indices 363860 364042 target 2 indices 364048 364091 target 3 indices 364101 364339 target 4 indices 364351 364432

; detector 2

Frame to eliminate is number ;363631 target 1 indices 363705 363894 target 2 indices 363899 363941 target 3 indices 363948 364145 target 4 indices 364152 364214

; detector 6

Frame to eliminate is number 364224 target 1 indices 367917 390593 target 2 indices 392277 399642 target 3 indices 401730 462578 target 4 indices 465457 490574

; detector 4

Frame to eliminate is number 364461 target 1 indices 364512 364645 target 2 indices 364649 364678 target 3 indices 364684 364845 target 4 indices 364851 364905

; detector 3

Frame to eliminate is number 445 target 1 indices 535 689 target 2 indices 697 724 target 3 indices 729 939 target 4 indices 949 1033

; detector 5

Frame to eliminate is number 1242 target 1 indices 1325 1464 target 2 indices 1467 1500 target 3 indices 3235 57667 target 4 indices 57824 58303

;--------------------------------------------------------------------------------- ; level2 data with only HV=200V frames ;---------------------------------------------------------------------------------

Time in minutes after launch, where we are at 200V analysis with D0 --> 1.17090 analysis with D2 --> 1.18033 analysis with D4 --> 1.17873 analysis with D6 --> 1.16950 mean value in minutes --> 1.1748650 mean value in seconds --> 70.491898

;--------------------------------------------------------------------------------- ; notes ;---------------------------------------------------------------------------------

To go to level 2, need calibration file, named as 'peaks_det108.sav' ==> ask Athiray

The level1 must be different for the CdTe detectors ==> check the level0 to level1 procedure and adapt