##Axpert Commands and examples
Command | Description |
---|---|
Q1 | Undocumented command: LocalInverterStatus (seconds from absorb), ParaExistInfo (seconds from end of Float), SccOkFlag, AllowSccOnFlag, ChargeAverageCurrent, SCC PWM Temperature, Inverter Temperature, Battery Temperature, Transformer Temperature, GPDAT, FanLockStatus, FanPWMDuty, FanPWM, SCCChargePowerWatts, ParaWarning, SYNFreq, InverterChargeStatus |
QPI | Device protocol ID inquiry |
QID | The device serial number inquiry |
QVFW | Main CPU Firmware version inquiry |
QVFW2 | Another CPU Firmware version inquiry |
QFLAG | Device flag status inquiry |
QPIGS | Device general status parameters inquiry: GridVoltage, GridFrequency, OutputVoltage, OutputFrequency, OutputApparentPower, OutputActivePower, OutputLoadPercent, BusVoltage, BatteryVoltage, BatteryChargingCurrent, BatteryCapacity, InverterHeatSinkTemperature, PV-InputCurrentForBattery, PV-InputVoltage, BatteryVoltageFromSCC, BatteryDischargeCurrent, DeviceStatus, |
QMOD | Device mode inquiry P: PowerOnMode, S: StandbyMode, L: LineMode, B: BatteryMode, F: FaultMode, H: PowerSavingMode |
QPIWS | Device warning status inquiry: Reserved, InverterFault, BusOver, BusUnder, BusSoftFail, LineFail, OPVShort, InverterVoltageTooLow, InverterVoltageTooHIGH, OverTemperature, FanLocked, BatteryVoltageHigh, BatteryLowAlarm, Reserved, ButteryUnderShutdown, Reserved, OverLoad, EEPROMFault, InverterSoftFail, SelfTestFail, OPDCVoltageOver, BatOpen, CurrentSensorFail, BatteryShort, PowerLimit, PVVoltageHigh, MPPTOverloadFault, MPPTOverloadWarning, BatteryTooLowToCharge, Reserved, Reserved |
QDI | The default setting value information |
QMCHGCR | Enquiry selectable value about max charging current |
QMUCHGCR | Enquiry selectable value about max utility charging current |
QBOOT | Enquiry DSP has bootstrap or not |
QOPM | Enquiry output mode |
QPIRI | Device rating information inquiry - nefunguje |
QPGS0 | Parallel information inquiry: TheParallelNumber, SerialNumber, WorkMode, FaultCode, GridVoltage, GridFrequency, OutputVoltage, OutputFrequency, OutputAparentPower, OutputActivePower, LoadPercentage, BatteryVoltage, BatteryChargingCurrent, BatteryCapacity, PV-InputVoltage, TotalChargingCurrent, Total-AC-OutputApparentPower, Total-AC-OutputActivePower, Total-AC-OutputPercentage, InverterStatus, OutputMode, ChargerSourcePriority, MaxChargeCurrent, MaxChargerRange, Max-AC-ChargerCurrent, PV-InputCurrentForBattery, BatteryDischargeCurrent |
QBV | Compensated Voltage, SoC |
PEXXX | Setting some status enable |
PDXXX | Setting some status disable |
PF | Setting control parameter to default value |
FXX | Setting device output rating frequency |
POP02 | set to SBU |
POP01 | set to Solar First |
POP00 | Set to UTILITY |
PBCVXX_X | Set battery re-charge voltage |
PBDVXX_X | Set battery re-discharge voltage |
PCP00 | Setting device charger priority: Utility First |
PCP01 | Setting device charger priority: Solar First |
PCP02 | Setting device charger priority: Solar and Utility |
PGRXX | Setting device grid working range |
PBTXX | Setting battery type |
PSDVXX_X | Setting battery cut-off voltage |
PCVVXX_X | Setting battery C.V. charging voltage |
PBFTXX_X | Setting battery float charging voltage |
PPVOCKCX | Setting PV OK condition |
PSPBX | Setting solar power balance |
MCHGC0XX | Setting max charging Current M XX |
MUCHGC002 | Setting utility max charging current 0 02 |
MUCHGC010 | Setting utility max charging current 0 10 |
MUCHGC020 | Setting utility max charging current 0 20 |
MUCHGC030 | Setting utility max charging current 0 30 |
POPMMX | Set output mode M 0:single, 1: parrallel, 2: PH1, 3: PH2, 4: PH3 |
#References