Skip to content

Commit

Permalink
Merge pull request #1280 from shaardie/power_supply_class
Browse files Browse the repository at this point in the history
Introduce Collector for Power Supply Class
  • Loading branch information
SuperQ authored Oct 30, 2019
2 parents d574b4b + d089776 commit f9d2bbe
Show file tree
Hide file tree
Showing 4 changed files with 547 additions and 0 deletions.
35 changes: 35 additions & 0 deletions collector/fixtures/e2e-64k-page-output.txt
Original file line number Diff line number Diff line change
Expand Up @@ -2393,6 +2393,40 @@ node_nfsd_server_rpcs_total 18628
# HELP node_nfsd_server_threads Total number of NFSd kernel threads that are running.
# TYPE node_nfsd_server_threads gauge
node_nfsd_server_threads 8
# HELP node_power_supply_capacity capacity value of /sys/class/power_supply/<power_supply>.
# TYPE node_power_supply_capacity gauge
node_power_supply_capacity{power_supply="BAT0"} 81
# HELP node_power_supply_cyclecount cyclecount value of /sys/class/power_supply/<power_supply>.
# TYPE node_power_supply_cyclecount gauge
node_power_supply_cyclecount{power_supply="BAT0"} 0
# HELP node_power_supply_energy_full energy_full value of /sys/class/power_supply/<power_supply>.
# TYPE node_power_supply_energy_full gauge
node_power_supply_energy_full{power_supply="BAT0"} 4.507e+07
# HELP node_power_supply_energy_full_design energy_full_design value of /sys/class/power_supply/<power_supply>.
# TYPE node_power_supply_energy_full_design gauge
node_power_supply_energy_full_design{power_supply="BAT0"} 4.752e+07
# HELP node_power_supply_energy_now energy_now value of /sys/class/power_supply/<power_supply>.
# TYPE node_power_supply_energy_now gauge
node_power_supply_energy_now{power_supply="BAT0"} 3.658e+07
# HELP node_power_supply_info info of /sys/class/power_supply/<power_supply>.
# TYPE node_power_supply_info gauge
node_power_supply_info{power_supply="AC",type="Mains"} 1
node_power_supply_info{capacity_level="Normal",manufacturer="LGC",model_name="LNV-45N1",power_supply="BAT0",serial_number="38109",status="Discharging",technology="Li-ion",type="Battery"} 1
# HELP node_power_supply_online online value of /sys/class/power_supply/<power_supply>.
# TYPE node_power_supply_online gauge
node_power_supply_online{power_supply="AC"} 0
# HELP node_power_supply_power_now power_now value of /sys/class/power_supply/<power_supply>.
# TYPE node_power_supply_power_now gauge
node_power_supply_power_now{power_supply="BAT0"} 5.002e+06
# HELP node_power_supply_present present value of /sys/class/power_supply/<power_supply>.
# TYPE node_power_supply_present gauge
node_power_supply_present{power_supply="BAT0"} 1
# HELP node_power_supply_voltage_min_design voltage_min_design value of /sys/class/power_supply/<power_supply>.
# TYPE node_power_supply_voltage_min_design gauge
node_power_supply_voltage_min_design{power_supply="BAT0"} 1.08e+07
# HELP node_power_supply_voltage_now voltage_now value of /sys/class/power_supply/<power_supply>.
# TYPE node_power_supply_voltage_now gauge
node_power_supply_voltage_now{power_supply="BAT0"} 1.166e+07
# HELP node_pressure_cpu_waiting_seconds_total Total time in seconds that processes have waited for CPU time
# TYPE node_pressure_cpu_waiting_seconds_total counter
node_pressure_cpu_waiting_seconds_total 14.036781000000001
Expand Down Expand Up @@ -2492,6 +2526,7 @@ node_scrape_collector_success{collector="netdev"} 1
node_scrape_collector_success{collector="netstat"} 1
node_scrape_collector_success{collector="nfs"} 1
node_scrape_collector_success{collector="nfsd"} 1
node_scrape_collector_success{collector="powersupplyclass"} 1
node_scrape_collector_success{collector="pressure"} 1
node_scrape_collector_success{collector="processes"} 1
node_scrape_collector_success{collector="qdisc"} 1
Expand Down
35 changes: 35 additions & 0 deletions collector/fixtures/e2e-output.txt
Original file line number Diff line number Diff line change
Expand Up @@ -2393,6 +2393,40 @@ node_nfsd_server_rpcs_total 18628
# HELP node_nfsd_server_threads Total number of NFSd kernel threads that are running.
# TYPE node_nfsd_server_threads gauge
node_nfsd_server_threads 8
# HELP node_power_supply_capacity capacity value of /sys/class/power_supply/<power_supply>.
# TYPE node_power_supply_capacity gauge
node_power_supply_capacity{power_supply="BAT0"} 81
# HELP node_power_supply_cyclecount cyclecount value of /sys/class/power_supply/<power_supply>.
# TYPE node_power_supply_cyclecount gauge
node_power_supply_cyclecount{power_supply="BAT0"} 0
# HELP node_power_supply_energy_full energy_full value of /sys/class/power_supply/<power_supply>.
# TYPE node_power_supply_energy_full gauge
node_power_supply_energy_full{power_supply="BAT0"} 45.07
# HELP node_power_supply_energy_full_design energy_full_design value of /sys/class/power_supply/<power_supply>.
# TYPE node_power_supply_energy_full_design gauge
node_power_supply_energy_full_design{power_supply="BAT0"} 47.52
# HELP node_power_supply_energy_watthour energy_watthour value of /sys/class/power_supply/<power_supply>.
# TYPE node_power_supply_energy_watthour gauge
node_power_supply_energy_watthour{power_supply="BAT0"} 36.58
# HELP node_power_supply_info info of /sys/class/power_supply/<power_supply>.
# TYPE node_power_supply_info gauge
node_power_supply_info{power_supply="AC",type="Mains"} 1
node_power_supply_info{capacity_level="Normal",manufacturer="LGC",model_name="LNV-45N1",power_supply="BAT0",serial_number="38109",status="Discharging",technology="Li-ion",type="Battery"} 1
# HELP node_power_supply_online online value of /sys/class/power_supply/<power_supply>.
# TYPE node_power_supply_online gauge
node_power_supply_online{power_supply="AC"} 0
# HELP node_power_supply_power_watt power_watt value of /sys/class/power_supply/<power_supply>.
# TYPE node_power_supply_power_watt gauge
node_power_supply_power_watt{power_supply="BAT0"} 5.002
# HELP node_power_supply_present present value of /sys/class/power_supply/<power_supply>.
# TYPE node_power_supply_present gauge
node_power_supply_present{power_supply="BAT0"} 1
# HELP node_power_supply_voltage_min_design voltage_min_design value of /sys/class/power_supply/<power_supply>.
# TYPE node_power_supply_voltage_min_design gauge
node_power_supply_voltage_min_design{power_supply="BAT0"} 10.8
# HELP node_power_supply_voltage_volt voltage_volt value of /sys/class/power_supply/<power_supply>.
# TYPE node_power_supply_voltage_volt gauge
node_power_supply_voltage_volt{power_supply="BAT0"} 11.66
# HELP node_pressure_cpu_waiting_seconds_total Total time in seconds that processes have waited for CPU time
# TYPE node_pressure_cpu_waiting_seconds_total counter
node_pressure_cpu_waiting_seconds_total 14.036781000000001
Expand Down Expand Up @@ -2492,6 +2526,7 @@ node_scrape_collector_success{collector="netdev"} 1
node_scrape_collector_success{collector="netstat"} 1
node_scrape_collector_success{collector="nfs"} 1
node_scrape_collector_success{collector="nfsd"} 1
node_scrape_collector_success{collector="powersupplyclass"} 1
node_scrape_collector_success{collector="pressure"} 1
node_scrape_collector_success{collector="processes"} 1
node_scrape_collector_success{collector="qdisc"} 1
Expand Down
283 changes: 283 additions & 0 deletions collector/fixtures/sys.ttar
Original file line number Diff line number Diff line change
Expand Up @@ -995,6 +995,289 @@ Lines: 1
1
Mode: 644
# ttar - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Directory: sys/class/power_supply
Mode: 755
# ttar - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Directory: sys/class/power_supply/AC
Mode: 755
# ttar - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Path: sys/class/power_supply/AC/online
Lines: 1
0
Mode: 444
# ttar - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Directory: sys/class/power_supply/AC/power
Mode: 755
# ttar - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Path: sys/class/power_supply/AC/power/async
Lines: 1
disabled
Mode: 644
# ttar - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Path: sys/class/power_supply/AC/power/autosuspend_delay_ms
Lines: 0
Mode: 644
# ttar - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Path: sys/class/power_supply/AC/power/control
Lines: 1
auto
Mode: 644
# ttar - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Path: sys/class/power_supply/AC/power/runtime_active_kids
Lines: 1
0
Mode: 444
# ttar - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Path: sys/class/power_supply/AC/power/runtime_active_time
Lines: 1
0
Mode: 444
# ttar - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Path: sys/class/power_supply/AC/power/runtime_enabled
Lines: 1
disabled
Mode: 444
# ttar - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Path: sys/class/power_supply/AC/power/runtime_status
Lines: 1
unsupported
Mode: 444
# ttar - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Path: sys/class/power_supply/AC/power/runtime_suspended_time
Lines: 1
0
Mode: 444
# ttar - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Path: sys/class/power_supply/AC/power/runtime_usage
Lines: 1
0
Mode: 444
# ttar - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Path: sys/class/power_supply/AC/power/wakeup
Lines: 1
enabled
Mode: 644
# ttar - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Path: sys/class/power_supply/AC/power/wakeup_abort_count
Lines: 1
0
Mode: 444
# ttar - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Path: sys/class/power_supply/AC/power/wakeup_active
Lines: 1
0
Mode: 444
# ttar - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Path: sys/class/power_supply/AC/power/wakeup_active_count
Lines: 1
1
Mode: 444
# ttar - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Path: sys/class/power_supply/AC/power/wakeup_count
Lines: 1
0
Mode: 444
# ttar - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Path: sys/class/power_supply/AC/power/wakeup_expire_count
Lines: 1
0
Mode: 444
# ttar - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Path: sys/class/power_supply/AC/power/wakeup_last_time_ms
Lines: 1
7888
Mode: 444
# ttar - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Path: sys/class/power_supply/AC/power/wakeup_max_time_ms
Lines: 1
2
Mode: 444
# ttar - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Path: sys/class/power_supply/AC/power/wakeup_prevent_sleep_time_ms
Lines: 1
0
Mode: 444
# ttar - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Path: sys/class/power_supply/AC/power/wakeup_total_time_ms
Lines: 1
2
Mode: 444
# ttar - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Path: sys/class/power_supply/AC/type
Lines: 1
Mains
Mode: 444
# ttar - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Path: sys/class/power_supply/AC/uevent
Lines: 2
POWER_SUPPLY_NAME=AC
POWER_SUPPLY_ONLINE=0
Mode: 644
# ttar - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Directory: sys/class/power_supply/BAT0
Mode: 755
# ttar - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Path: sys/class/power_supply/BAT0/alarm
Lines: 1
2253000
Mode: 644
# ttar - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Path: sys/class/power_supply/BAT0/capacity
Lines: 1
81
Mode: 444
# ttar - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Path: sys/class/power_supply/BAT0/capacity_level
Lines: 1
Normal
Mode: 444
# ttar - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Path: sys/class/power_supply/BAT0/charge_start_threshold
Lines: 1
95
Mode: 644
# ttar - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Path: sys/class/power_supply/BAT0/charge_stop_threshold
Lines: 1
100
Mode: 644
# ttar - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Path: sys/class/power_supply/BAT0/cycle_count
Lines: 1
0
Mode: 444
# ttar - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Path: sys/class/power_supply/BAT0/energy_full
Lines: 1
45070000
Mode: 444
# ttar - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Path: sys/class/power_supply/BAT0/energy_full_design
Lines: 1
47520000
Mode: 444
# ttar - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Path: sys/class/power_supply/BAT0/energy_now
Lines: 1
36580000
Mode: 444
# ttar - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Path: sys/class/power_supply/BAT0/manufacturer
Lines: 1
LGC
Mode: 444
# ttar - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Path: sys/class/power_supply/BAT0/model_name
Lines: 1
LNV-45N1
Mode: 444
# ttar - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Directory: sys/class/power_supply/BAT0/power
Mode: 755
# ttar - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Path: sys/class/power_supply/BAT0/power/async
Lines: 1
disabled
Mode: 644
# ttar - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Path: sys/class/power_supply/BAT0/power/autosuspend_delay_ms
Lines: 0
Mode: 644
# ttar - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Path: sys/class/power_supply/BAT0/power/control
Lines: 1
auto
Mode: 644
# ttar - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Path: sys/class/power_supply/BAT0/power/runtime_active_kids
Lines: 1
0
Mode: 444
# ttar - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Path: sys/class/power_supply/BAT0/power/runtime_active_time
Lines: 1
0
Mode: 444
# ttar - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Path: sys/class/power_supply/BAT0/power/runtime_enabled
Lines: 1
disabled
Mode: 444
# ttar - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Path: sys/class/power_supply/BAT0/power/runtime_status
Lines: 1
unsupported
Mode: 444
# ttar - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Path: sys/class/power_supply/BAT0/power/runtime_suspended_time
Lines: 1
0
Mode: 444
# ttar - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Path: sys/class/power_supply/BAT0/power/runtime_usage
Lines: 1
0
Mode: 444
# ttar - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Path: sys/class/power_supply/BAT0/power_now
Lines: 1
5002000
Mode: 444
# ttar - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Path: sys/class/power_supply/BAT0/present
Lines: 1
1
Mode: 444
# ttar - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Path: sys/class/power_supply/BAT0/serial_number
Lines: 1
38109
Mode: 444
# ttar - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Path: sys/class/power_supply/BAT0/status
Lines: 1
Discharging
Mode: 444
# ttar - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Path: sys/class/power_supply/BAT0/technology
Lines: 1
Li-ion
Mode: 444
# ttar - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Path: sys/class/power_supply/BAT0/type
Lines: 1
Battery
Mode: 444
# ttar - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Path: sys/class/power_supply/BAT0/uevent
Lines: 16
POWER_SUPPLY_NAME=BAT0
POWER_SUPPLY_STATUS=Discharging
POWER_SUPPLY_PRESENT=1
POWER_SUPPLY_TECHNOLOGY=Li-ion
POWER_SUPPLY_CYCLE_COUNT=0
POWER_SUPPLY_VOLTAGE_MIN_DESIGN=10800000
POWER_SUPPLY_VOLTAGE_NOW=11660000
POWER_SUPPLY_POWER_NOW=5002000
POWER_SUPPLY_ENERGY_FULL_DESIGN=47520000
POWER_SUPPLY_ENERGY_FULL=45070000
POWER_SUPPLY_ENERGY_NOW=36580000
POWER_SUPPLY_CAPACITY=81
POWER_SUPPLY_CAPACITY_LEVEL=Normal
POWER_SUPPLY_MODEL_NAME=LNV-45N1
POWER_SUPPLY_MANUFACTURER=LGC
POWER_SUPPLY_SERIAL_NUMBER=38109
Mode: 644
# ttar - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Path: sys/class/power_supply/BAT0/voltage_min_design
Lines: 1
10800000
Mode: 444
# ttar - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Path: sys/class/power_supply/BAT0/voltage_now
Lines: 1
11660000
Mode: 444
Directory: sys/class/thermal
Mode: 755
# ttar - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Expand Down
Loading

0 comments on commit f9d2bbe

Please sign in to comment.