Notifications
You must be signed in to change notification settings - Fork 2.4k
Commit
This commit does not belong to any branch on this repository, and may belong to a fork outside of the repository.
Merge pull request #117 from shaardie/power_supply_class
Add Support for /sys/class/power_supply
- Loading branch information
Showing
3 changed files
with
408 additions
and
0 deletions.
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,188 @@ | ||
// Copyright 2018 The Prometheus Authors | ||
// Licensed under the Apache License, Version 2.0 (the "License"); | ||
// you may not use this file except in compliance with the License. | ||
// You may obtain a copy of the License at | ||
// | ||
// http://www.apache.org/licenses/LICENSE-2.0 | ||
// | ||
// Unless required by applicable law or agreed to in writing, software | ||
// distributed under the License is distributed on an "AS IS" BASIS, | ||
// WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. | ||
// See the License for the specific language governing permissions and | ||
// limitations under the License. | ||
|
||
// +build !windows | ||
|
||
package sysfs | ||
|
||
import ( | ||
"fmt" | ||
"io/ioutil" | ||
"os" | ||
"reflect" | ||
"strconv" | ||
"strings" | ||
|
||
"github.com/prometheus/procfs/internal/util" | ||
) | ||
|
||
// PowerSupply contains info from files in /sys/class/power_supply for a single power supply. | ||
type PowerSupply struct { | ||
Name string // Power Supply Name | ||
Authentic *int64 `fileName:"authentic"` // /sys/class/power_suppy/<Name>/authentic | ||
Calibrate *int64 `fileName:"calibrate"` // /sys/class/power_suppy/<Name>/calibrate | ||
Capacity *int64 `fileName:"capacity"` // /sys/class/power_suppy/<Name>/capacity | ||
CapacityAlertMax *int64 `fileName:"capacity_alert_max"` // /sys/class/power_suppy/<Name>/capacity_alert_max | ||
CapacityAlertMin *int64 `fileName:"capacity_alert_min"` // /sys/class/power_suppy/<Name>/capacity_alert_min | ||
CapacityLevel string `fileName:"capacity_level"` // /sys/class/power_suppy/<Name>/capacity_level | ||
ChargeAvg *int64 `fileName:"charge_avg"` // /sys/class/power_suppy/<Name>/charge_avg | ||
ChargeControlLimit *int64 `fileName:"charge_control_limit"` // /sys/class/power_suppy/<Name>/charge_control_limit | ||
ChargeControlLimitMax *int64 `fileName:"charge_control_limit_max"` // /sys/class/power_suppy/<Name>/charge_control_limit_max | ||
ChargeCounter *int64 `fileName:"charge_counter"` // /sys/class/power_suppy/<Name>/charge_counter | ||
ChargeEmpty *int64 `fileName:"charge_empty"` // /sys/class/power_suppy/<Name>/charge_empty | ||
ChargeEmptyDesign *int64 `fileName:"charge_empty_design"` // /sys/class/power_suppy/<Name>/charge_empty_design | ||
ChargeFull *int64 `fileName:"charge_full"` // /sys/class/power_suppy/<Name>/charge_full | ||
ChargeFullDesign *int64 `fileName:"charge_full_design"` // /sys/class/power_suppy/<Name>/charge_full_design | ||
ChargeNow *int64 `fileName:"charge_now"` // /sys/class/power_suppy/<Name>/charge_now | ||
ChargeTermCurrent *int64 `fileName:"charge_term_current"` // /sys/class/power_suppy/<Name>/charge_term_current | ||
ChargeType string `fileName:"charge_type"` // /sys/class/power_supply/<Name>/charge_type | ||
ConstantChargeCurrent *int64 `fileName:"constant_charge_current"` // /sys/class/power_suppy/<Name>/constant_charge_current | ||
ConstantChargeCurrentMax *int64 `fileName:"constant_charge_current_max"` // /sys/class/power_suppy/<Name>/constant_charge_current_max | ||
ConstantChargeVoltage *int64 `fileName:"constant_charge_voltage"` // /sys/class/power_suppy/<Name>/constant_charge_voltage | ||
ConstantChargeVoltageMax *int64 `fileName:"constant_charge_voltage_max"` // /sys/class/power_suppy/<Name>/constant_charge_voltage_max | ||
CurrentAvg *int64 `fileName:"current_avg"` // /sys/class/power_suppy/<Name>/current_avg | ||
CurrentBoot *int64 `fileName:"current_boot"` // /sys/class/power_suppy/<Name>/current_boot | ||
CurrentMax *int64 `fileName:"current_max"` // /sys/class/power_suppy/<Name>/current_max | ||
CurrentNow *int64 `fileName:"current_now"` // /sys/class/power_suppy/<Name>/current_now | ||
CycleCount *int64 `fileName:"cycle_count"` // /sys/class/power_suppy/<Name>/cycle_count | ||
EnergyAvg *int64 `fileName:"energy_avg"` // /sys/class/power_supply/<Name>/energy_avg | ||
EnergyEmpty *int64 `fileName:"energy_empty"` // /sys/class/power_suppy/<Name>/energy_empty | ||
EnergyEmptyDesign *int64 `fileName:"energy_empty_design"` // /sys/class/power_suppy/<Name>/energy_empty_design | ||
EnergyFull *int64 `fileName:"energy_full"` // /sys/class/power_suppy/<Name>/energy_full | ||
EnergyFullDesign *int64 `fileName:"energy_full_design"` // /sys/class/power_suppy/<Name>/energy_full_design | ||
EnergyNow *int64 `fileName:"energy_now"` // /sys/class/power_supply/<Name>/energy_now | ||
Health string `fileName:"health"` // /sys/class/power_suppy/<Name>/health | ||
InputCurrentLimit *int64 `fileName:"input_current_limit"` // /sys/class/power_suppy/<Name>/input_current_limit | ||
Manufacturer string `fileName:"manufacturer"` // /sys/class/power_suppy/<Name>/manufacturer | ||
ModelName string `fileName:"model_name"` // /sys/class/power_suppy/<Name>/model_name | ||
Online *int64 `fileName:"online"` // /sys/class/power_suppy/<Name>/online | ||
PowerAvg *int64 `fileName:"power_avg"` // /sys/class/power_suppy/<Name>/power_avg | ||
PowerNow *int64 `fileName:"power_now"` // /sys/class/power_suppy/<Name>/power_now | ||
PrechargeCurrent *int64 `fileName:"precharge_current"` // /sys/class/power_suppy/<Name>/precharge_current | ||
Present *int64 `fileName:"present"` // /sys/class/power_suppy/<Name>/present | ||
Scope *int64 `fileName:"scope"` // /sys/class/power_suppy/<Name>/scope | ||
SerialNumber string `fileName:"serial_number"` // /sys/class/power_suppy/<Name>/serial_number | ||
Status string `fileName:"status"` // /sys/class/power_supply/<Name>/status | ||
Technology string `fileName:"technology"` // /sys/class/power_suppy/<Name>/technology | ||
Temp *int64 `fileName:"temp"` // /sys/class/power_suppy/<Name>/temp | ||
TempAlertMax *int64 `fileName:"temp_alert_max"` // /sys/class/power_suppy/<Name>/temp_alert_max | ||
TempAlertMin *int64 `fileName:"temp_alert_min"` // /sys/class/power_suppy/<Name>/temp_alert_min | ||
TempAmbient *int64 `fileName:"temp_ambient"` // /sys/class/power_suppy/<Name>/temp_ambient | ||
TempAmbientMax *int64 `fileName:"temp_ambient_max"` // /sys/class/power_suppy/<Name>/temp_ambient_max | ||
TempAmbientMin *int64 `fileName:"temp_ambient_min"` // /sys/class/power_suppy/<Name>/temp_ambient_min | ||
TempMax *int64 `fileName:"temp_max"` // /sys/class/power_suppy/<Name>/temp_max | ||
TempMin *int64 `fileName:"temp_min"` // /sys/class/power_suppy/<Name>/temp_min | ||
TimeToEmptyAvg *int64 `fileName:"time_to_empty_avg"` // /sys/class/power_suppy/<Name>/time_to_empty_avg | ||
TimeToEmptyNow *int64 `fileName:"time_to_empty_now"` // /sys/class/power_suppy/<Name>/time_to_empty_now | ||
TimeToFullAvg *int64 `fileName:"time_to_full_avg"` // /sys/class/power_suppy/<Name>/time_to_full_avg | ||
TimeToFullNow *int64 `fileName:"time_to_full_now"` // /sys/class/power_suppy/<Name>/time_to_full_now | ||
Type string `fileName:"type"` // /sys/class/power_supply/<Name>/type | ||
UsbType string `fileName:"usb_type"` // /sys/class/power_supply/<Name>/usb_type | ||
VoltageAvg *int64 `fileName:"voltage_avg"` // /sys/class/power_supply/<Name>/voltage_avg | ||
VoltageBoot *int64 `fileName:"voltage_boot"` // /sys/class/power_suppy/<Name>/voltage_boot | ||
VoltageMax *int64 `fileName:"voltage_max"` // /sys/class/power_suppy/<Name>/voltage_max | ||
VoltageMaxDesign *int64 `fileName:"voltage_max_design"` // /sys/class/power_suppy/<Name>/voltage_max_design | ||
VoltageMin *int64 `fileName:"voltage_min"` // /sys/class/power_suppy/<Name>/voltage_min | ||
VoltageMinDesign *int64 `fileName:"voltage_min_design"` // /sys/class/power_suppy/<Name>/voltage_min_design | ||
VoltageNow *int64 `fileName:"voltage_now"` // /sys/class/power_supply/<Name>/voltage_now | ||
VoltageOCV *int64 `fileName:"voltage_ocv"` // /sys/class/power_suppy/<Name>/voltage_ocv | ||
} | ||
|
||
// PowerSupplyClass is a collection of every power supply in /sys/class/power_supply/. | ||
// The map keys are the names of the power supplies. | ||
type PowerSupplyClass map[string]PowerSupply | ||
|
||
// NewPowerSupplyClass returns info for all power supplies read from /sys/class/power_supply/. | ||
func NewPowerSupplyClass() (PowerSupplyClass, error) { | ||
fs, err := NewFS(DefaultMountPoint) | ||
if err != nil { | ||
return nil, err | ||
} | ||
|
||
return fs.NewPowerSupplyClass() | ||
} | ||
|
||
// NewPowerSupplyClass returns info for all power supplies read from /sys/class/power_supply/. | ||
func (fs FS) NewPowerSupplyClass() (PowerSupplyClass, error) { | ||
path := fs.Path("class/power_supply") | ||
|
||
powerSupplyDirs, err := ioutil.ReadDir(path) | ||
if err != nil { | ||
return PowerSupplyClass{}, fmt.Errorf("cannot access %s dir %s", path, err) | ||
} | ||
|
||
powerSupplyClass := PowerSupplyClass{} | ||
for _, powerSupplyDir := range powerSupplyDirs { | ||
powerSupply, err := powerSupplyClass.parsePowerSupply(path + "/" + powerSupplyDir.Name()) | ||
if err != nil { | ||
return nil, err | ||
} | ||
powerSupply.Name = powerSupplyDir.Name() | ||
powerSupplyClass[powerSupplyDir.Name()] = *powerSupply | ||
} | ||
return powerSupplyClass, nil | ||
} | ||
|
||
func (psc PowerSupplyClass) parsePowerSupply(powerSupplyPath string) (*PowerSupply, error) { | ||
powerSupply := PowerSupply{} | ||
powerSupplyElem := reflect.ValueOf(&powerSupply).Elem() | ||
powerSupplyType := reflect.TypeOf(powerSupply) | ||
|
||
//start from 1 - skip the Name field | ||
for i := 1; i < powerSupplyElem.NumField(); i++ { | ||
fieldType := powerSupplyType.Field(i) | ||
fieldValue := powerSupplyElem.Field(i) | ||
|
||
if fieldType.Tag.Get("fileName") == "" { | ||
panic(fmt.Errorf("field %s does not have a filename tag", fieldType.Name)) | ||
} | ||
|
||
value, err := util.SysReadFile(powerSupplyPath + "/" + fieldType.Tag.Get("fileName")) | ||
|
||
if err != nil { | ||
if os.IsNotExist(err) || err.Error() == "operation not supported" || err.Error() == "invalid argument" { | ||
continue | ||
} | ||
return nil, fmt.Errorf("could not access file %s: %s", fieldType.Tag.Get("fileName"), err) | ||
} | ||
|
||
switch fieldValue.Kind() { | ||
case reflect.String: | ||
fieldValue.SetString(value) | ||
case reflect.Ptr: | ||
var int64ptr *int64 | ||
switch fieldValue.Type() { | ||
case reflect.TypeOf(int64ptr): | ||
var intValue int64 | ||
if strings.HasPrefix(value, "0x") { | ||
intValue, err = strconv.ParseInt(value[2:], 16, 64) | ||
if err != nil { | ||
return nil, fmt.Errorf("expected hex value for %s, got: %s", fieldType.Name, value) | ||
} | ||
} else { | ||
intValue, err = strconv.ParseInt(value, 10, 64) | ||
if err != nil { | ||
return nil, fmt.Errorf("expected Uint64 value for %s, got: %s", fieldType.Name, value) | ||
} | ||
} | ||
fieldValue.Set(reflect.ValueOf(&intValue)) | ||
default: | ||
return nil, fmt.Errorf("unhandled pointer type %q", fieldValue.Type()) | ||
} | ||
default: | ||
return nil, fmt.Errorf("unhandled type %q", fieldValue.Kind()) | ||
} | ||
} | ||
|
||
return &powerSupply, nil | ||
} |
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,80 @@ | ||
// Copyright 2018 The Prometheus Authors | ||
// Licensed under the Apache License, Version 2.0 (the "License"); | ||
// you may not use this file except in compliance with the License. | ||
// You may obtain a copy of the License at | ||
// | ||
// http://www.apache.org/licenses/LICENSE-2.0 | ||
// | ||
// Unless required by applicable law or agreed to in writing, software | ||
// distributed under the License is distributed on an "AS IS" BASIS, | ||
// WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. | ||
// See the License for the specific language governing permissions and | ||
// limitations under the License. | ||
|
||
// +build !windows | ||
|
||
package sysfs | ||
|
||
import ( | ||
"encoding/json" | ||
"reflect" | ||
"testing" | ||
) | ||
|
||
func TestNewPowerSupplyClass(t *testing.T) { | ||
fs, err := NewFS("fixtures") | ||
if err != nil { | ||
t.Fatal(err) | ||
} | ||
|
||
psc, err := fs.NewPowerSupplyClass() | ||
if err != nil { | ||
t.Fatal(err) | ||
} | ||
|
||
var ( | ||
acOnline int64 = 0 | ||
bat0Capacity int64 = 98 | ||
bat0CycleCount int64 = 0 | ||
bat0EnergyFull int64 = 50060000 | ||
bat0EnergyFullDesign int64 = 47520000 | ||
bat0EnergyNow int64 = 49450000 | ||
bat0PowerNow int64 = 4830000 | ||
bat0Present int64 = 1 | ||
bat0VoltageMinDesign int64 = 10800000 | ||
bat0VoltageNow int64 = 12229000 | ||
) | ||
|
||
powerSupplyClass := PowerSupplyClass{ | ||
"AC": { | ||
Name: "AC", | ||
Type: "Mains", | ||
Online: &acOnline, | ||
}, | ||
"BAT0": { | ||
Name: "BAT0", | ||
Capacity: &bat0Capacity, | ||
CapacityLevel: "Normal", | ||
CycleCount: &bat0CycleCount, | ||
EnergyFull: &bat0EnergyFull, | ||
EnergyFullDesign: &bat0EnergyFullDesign, | ||
EnergyNow: &bat0EnergyNow, | ||
Manufacturer: "LGC", | ||
ModelName: "LNV-45N1", | ||
PowerNow: &bat0PowerNow, | ||
Present: &bat0Present, | ||
SerialNumber: "38109", | ||
Status: "Discharging", | ||
Technology: "Li-ion", | ||
Type: "Battery", | ||
VoltageMinDesign: &bat0VoltageMinDesign, | ||
VoltageNow: &bat0VoltageNow, | ||
}, | ||
} | ||
|
||
if !reflect.DeepEqual(powerSupplyClass, psc) { | ||
want, _ := json.Marshal(powerSupplyClass) | ||
get, _ := json.Marshal(psc) | ||
t.Errorf("Result not correct: want %v, have %v.", string(want), string(get)) | ||
} | ||
} |
Oops, something went wrong.