After instrumentor injects the instrumentation device and overriden envs to the workload template spec, these value might get over written if the user applies his workload manifest again.
At this point, the instrumentor should pick this up and insert odigos values back into the workload manifest template spec per each container.
Current reconciler only checks if something in the env changed to trigger recalculation, but we should also do it when something in the resource changes, so to inject the resource again if needed