Fix OCTT test cases 2 #383

Merged
merged 6 commits into from
Nov 6, 2024
Merged

Fix OCTT test cases 2 #383

merged 6 commits into from
Nov 6, 2024

Conversation

matth-x
Copy link
Owner

@matth-x matth-x commented Nov 6, 2024

Follow up PR of #344

These patches improve the message ID generation and fix some timing issues to pass further OCTT test cases.

heakins and others added 6 commits November 6, 2024 08:07
OCPP-J Message IDs must be unique per "Connection URL", including across
different WebSocket connection instances. Below is the text from the
Test Laboratory Working Instruction describing OCA's position.

    The message IDs were intended to at least be unique per defined
    'Connection URL' as specified by section 3.1.1 of the OCPP-J
    specification (In case of OCPP 1.6) or "Part 4 - JSON over WebSockets
    implementation guide" (In case of OCPP 2.0.1). By this it is meant
    unique on any WebSocket connection using the same unique Charging
    Station identifier. An erratum will be published in the near future for
    this. Please notify the vendors about this still upcoming erratum. From
    this moment on, no retests will be granted for this issue.

    To verify if a Charging Station is behaving correctly, testcases 013,
    014, 015, 016, 032, 034 and 044 can be used for checking this after
    rebooting, test cases 036, 037_1, 037_2, 037_3, 038 and 039 can be used
    for testing the behavior a when reconnection. If an incrementally
    increasing message ID is being used by the system, then it should NOT
    be reset to 0 or 1 after reconnection / reboot.

    To verify if a CSMS is behaving correctly, any testcase can be used
    after stopping the test session. Because stopping the test session
    will close the connection with the CSMS.

Changes:
* Added a Random Number Generator (RNG) platform API to microOCPP, with
  a hashed-time based default implementation.
* Add UUID generation for Message IDs using the RNG API.
Heartbeat messages are dropped from the request queue if
they are more than 4 seconds old. This is on recommendation
of the OCA to keep the heartbeat interval within 4s of the
interval provided by the CSMS.

If heartbeat messages are queued for longer than 4s,
the resulting interval will exceed this recommendation.
@matth-x matth-x merged commit 2d5dee9 into main Nov 6, 2024
7 of 8 checks passed
@matth-x matth-x deleted the fix/octt_16_2 branch November 6, 2024 13:48