Notifications
You must be signed in to change notification settings - Fork 21
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
Enable PEL for Bios Handler Class #560
base: 1110
Are you sure you want to change the base?
Conversation
5ff3f64
to
7dc81ad
Compare
6c6dcc9
to
9b6fbf0
Compare
9b6fbf0
to
b9a047b
Compare
vpd-manager/src/bios_handler.cpp
Outdated
// TODO: log a predicitive PEL. | ||
logging::logMessage("Invalid typre received from BIOS table."); | ||
EventLogger::createSyncPel( | ||
types::ErrorType::InvalidVpdMessage, |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Should the type be DbusFailure
since there is an invalid type in the D-Bus message received from BIOS Config Manager?
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Done
vpd-manager/src/bios_handler.cpp
Outdated
logging::logMessage( | ||
"Invalid type read for memory mirror mode value from DBus. Skip writing to VPD"); | ||
EventLogger::createSyncPel( | ||
types::ErrorType::InvalidVpdMessage, |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Should type be DbusFailure
here?
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Done
This commit adds code to log PEL in BiosHandler class, in case of exceptions occurred while updating the the BIOS attribute values. output: ''' root@p10bmc:/tmp# peltool -i 0x5000254B { "Private Header": { "Section Version": "1", "Sub-section type": "0", "Created by": "bmc vpd", "Created at": "01/15/2025 09:12:41", "Committed at": "01/15/2025 09:12:41", "Creator Subsystem": "BMC", "CSSVER": "", "Platform Log Id": "0x5000254B", "Entry Id": "0x5000254B", "BMC Event Log Id": "15" }, "User Header": { "Section Version": "1", "Sub-section type": "0", "Log Committed by": "bmc error logging", "Subsystem": "CEC Hardware - VPD Interface", "Event Scope": "Entire Platform", "Event Severity": "Informational Event", "Event Type": "Miscellaneous, Informational Only", "Action Flags": [ "Event not customer viewable", "Report Externally" ], "Host Transmission": "Not Sent", "HMC Transmission": "Not Sent" }, "Primary SRC": { "Section Version": "1", "Sub-section type": "1", "Created by": "bmc vpd", "SRC Version": "0x02", "SRC Format": "0x55", "Virtual Progress SRC": "False", "I5/OS Service Event Bit": "False", "Hypervisor Dump Initiated":"False", "Backplane CCIN": "2E2D", "Terminate FW Error": "False", "Deconfigured": "False", "Guarded": "False", "Error Details": { "Message": "A Dbus internal error occurred." }, "Valid Word Count": "0x09", "Reference Code": "BD554005", "Hex Word 2": "00000055", "Hex Word 3": "2E2D0010", "Hex Word 4": "00000000", "Hex Word 5": "00000000", "Hex Word 6": "00000000", "Hex Word 7": "00000000", "Hex Word 8": "00000000", "Hex Word 9": "00000000", "Callout Section": { "Callout Count": "1", "Callouts": [{ "FRU Type": "Maintenance Procedure Required", "Priority": "Mandatory, replace all with this type as a unit", "Procedure": "BMC0001" }] } }, "Extended User Header": { "Section Version": "1", "Sub-section type": "0", "Created by": "bmc error logging", "Reporting Machine Type": " ", "Reporting Serial Number": " ", "FW Released Ver": "RB1110_025", "FW SubSys Version": "fw1110.00-3.53", "Common Ref Time": "00/00/0000 00:00:00", "Symptom Id Len": "20", "Symptom Id": "BD554005_2E2D0010" }, "Failing MTMS": { "Section Version": "1", "Sub-section type": "0", "Created by": "bmc error logging", "Machine Type Model": " ", "Serial Number": " " }, "User Data 0": { "Section Version": "1", "Sub-section type": "1", "Created by": "bmc error logging", "BMCLoad": "1.62 1.17 0.89", "BMCState": "Ready", "BMCUptime": "0y 0d 0h 56m 29s", "BootState": "Unspecified", "ChassisState": "Off", "FW Version ID": "fw1110.00-3.53-1110.2503.20250109a (RB1110_025)", "HostState": "Off", "System IM": "50001001" }, "User Data 1": { "Section Version": "1", "Sub-section type": "1", "Created by": "bmc error logging", "DESCRIPTION": "DBus call to update NVRAM value in pending attribute failed. Test Error", "FileName": "/usr/src/debug/openpower-fru-vpd/1.0+git/vpd-manager/src/bios_handler.cpp", "FunctionName": "saveClearNvramToBios", "InteranlRc": "0", "UserData1": "", "UserData2": "" } } ''' Signed-off-by: RekhaAparna01 <vrekhaaparna@ibm.com>
b9a047b
to
59195f4
Compare
This commit adds code to log PEL in BiosHandler class, in case of exceptions occurred while updating the the BIOS attribute values.
output: