Notifications
You must be signed in to change notification settings - Fork 640
Commit
This commit does not belong to any branch on this repository, and may belong to a fork outside of the repository.
- Loading branch information
1 parent
f062380
commit 906752d
Showing
2 changed files
with
275 additions
and
0 deletions.
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,249 @@ | ||
package charger | ||
|
||
// LICENSE | ||
|
||
// Copyright (c) 2024 premultiply | ||
|
||
// This module is NOT covered by the MIT license. All rights reserved. | ||
|
||
// The above copyright notice and this permission notice shall be included in all | ||
// copies or substantial portions of the Software. | ||
|
||
// THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR | ||
// IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY, | ||
// FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. IN NO EVENT SHALL THE | ||
// AUTHORS OR COPYRIGHT HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER | ||
// LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM, | ||
// OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE | ||
// SOFTWARE. | ||
|
||
import ( | ||
"encoding/binary" | ||
"fmt" | ||
|
||
"github.com/evcc-io/evcc/api" | ||
"github.com/evcc-io/evcc/util" | ||
"github.com/evcc-io/evcc/util/modbus" | ||
"github.com/evcc-io/evcc/util/sponsor" | ||
"github.com/volkszaehler/mbmd/encoding" | ||
) | ||
|
||
// Solax charger implementation | ||
type Solax struct { | ||
log *util.Logger | ||
conn *modbus.Connection | ||
curr uint16 | ||
} | ||
|
||
const ( | ||
// holding (FC 0x03, 0x06, 0x10) | ||
solaxRegDeviceMode = 0x060D // uint16 | ||
solaxRegStartChargeMode = 0x0610 // uint16 | ||
solaxRegPhases = 0x0625 // uint16 | ||
solaxRegCommandControl = 0x0627 // uint16 | ||
solaxRegMaxCurrent = 0x0628 // uint16 0.01A | ||
|
||
// input (FC 0x04) | ||
solaxRegVoltages = 0x0000 // 3x uint16 0.01V | ||
solaxRegCurrents = 0x0004 // 3x uint16 0.01A | ||
solaxRegActivePower = 0x000B // uint16 1W | ||
solaxRegTotalEnergy = 0x0010 // uint32s 0.1kWh | ||
solaxRegState = 0x001D // uint16 | ||
) | ||
|
||
func init() { | ||
registry.Add("solax", NewSolaxFromConfig) | ||
} | ||
|
||
// NewSolaxFromConfig creates a Solax charger from generic config | ||
func NewSolaxFromConfig(other map[string]interface{}) (api.Charger, error) { | ||
cc := modbus.Settings{ | ||
ID: 1, | ||
} | ||
|
||
if err := util.DecodeOther(other, &cc); err != nil { | ||
return nil, err | ||
} | ||
|
||
return NewSolax(cc.URI, cc.Device, cc.Comset, cc.Baudrate, modbus.ProtocolFromRTU(cc.RTU), cc.ID) | ||
} | ||
|
||
// NewSolax creates Solax charger | ||
func NewSolax(uri, device, comset string, baudrate int, proto modbus.Protocol, id uint8) (api.Charger, error) { | ||
conn, err := modbus.NewConnection(uri, device, comset, baudrate, proto, id) | ||
if err != nil { | ||
return nil, err | ||
} | ||
|
||
if !sponsor.IsAuthorized() { | ||
return nil, api.ErrSponsorRequired | ||
} | ||
|
||
log := util.NewLogger("solax") | ||
conn.Logger(log.TRACE) | ||
|
||
wb := &Solax{ | ||
log: log, | ||
conn: conn, | ||
curr: 600, // assume min current | ||
} | ||
|
||
// get initial state from charger | ||
curr, err := wb.getCurrent() | ||
if err != nil { | ||
return nil, fmt.Errorf("current limit: %w", err) | ||
} | ||
if curr != 0 { | ||
wb.curr = curr | ||
} | ||
|
||
return wb, err | ||
} | ||
|
||
func (wb *Solax) setCurrent(current uint16) error { | ||
_, err := wb.conn.WriteSingleRegister(solaxRegMaxCurrent, current) | ||
|
||
return err | ||
} | ||
|
||
func (wb *Solax) getCurrent() (uint16, error) { | ||
b, err := wb.conn.ReadHoldingRegisters(solaxRegMaxCurrent, 1) | ||
if err != nil { | ||
return 0, err | ||
} | ||
|
||
return binary.BigEndian.Uint16(b), nil | ||
} | ||
|
||
// getPhaseValues returns 3 sequential register values | ||
func (wb *Solax) getPhaseValues(reg uint16) (float64, float64, float64, error) { | ||
b, err := wb.conn.ReadInputRegisters(reg, 3) | ||
if err != nil { | ||
return 0, 0, 0, err | ||
} | ||
|
||
var res [3]float64 | ||
for i := range res { | ||
res[i] = float64(binary.BigEndian.Uint16(b[2*i:])) / 100 | ||
} | ||
|
||
return res[0], res[1], res[2], nil | ||
} | ||
|
||
// Status implements the api.Charger interface | ||
func (wb *Solax) Status() (api.ChargeStatus, error) { | ||
b, err := wb.conn.ReadInputRegisters(solaxRegState, 1) | ||
if err != nil { | ||
return api.StatusNone, err | ||
} | ||
|
||
switch s := encoding.Uint16(b); s { | ||
case | ||
0, // "Available" | ||
5: // "Unavailable" | ||
return api.StatusA, nil | ||
case | ||
1, // "Preparing" | ||
8, // "SuspendedEVSE" | ||
7, // "SuspendedEV" | ||
3: // "Finishing" | ||
return api.StatusB, nil | ||
case | ||
2: // "Charging" | ||
return api.StatusC, nil | ||
case | ||
6, // "Reserved" | ||
4: // "Faulted" | ||
return api.StatusF, nil | ||
default: | ||
return api.StatusNone, fmt.Errorf("invalid status: %d", s) | ||
} | ||
} | ||
|
||
// Enabled implements the api.Charger interface | ||
func (wb *Solax) Enabled() (bool, error) { | ||
curr, err := wb.getCurrent() | ||
|
||
return curr != 0, err | ||
} | ||
|
||
// Enable implements the api.Charger interface | ||
func (wb *Solax) Enable(enable bool) error { | ||
var current uint16 | ||
if enable { | ||
current = wb.curr | ||
} | ||
|
||
return wb.setCurrent(current) | ||
} | ||
|
||
// MaxCurrent implements the api.Charger interface | ||
func (wb *Solax) MaxCurrent(current int64) error { | ||
return wb.MaxCurrentMillis(float64(current)) | ||
} | ||
|
||
var _ api.ChargerEx = (*Solax)(nil) | ||
|
||
// MaxCurrentMillis implements the api.ChargerEx interface | ||
func (wb *Solax) MaxCurrentMillis(current float64) error { | ||
if current < 6 { | ||
return fmt.Errorf("invalid current %.1f", current) | ||
} | ||
|
||
wb.curr = uint16(current * 100) | ||
|
||
return wb.setCurrent(wb.curr) | ||
} | ||
|
||
var _ api.Meter = (*Solax)(nil) | ||
|
||
// CurrentPower implements the api.Meter interface | ||
func (wb *Solax) CurrentPower() (float64, error) { | ||
b, err := wb.conn.ReadInputRegisters(solaxRegActivePower, 1) | ||
if err != nil { | ||
return 0, err | ||
} | ||
|
||
return float64(binary.BigEndian.Uint16(b)), err | ||
} | ||
|
||
var _ api.MeterEnergy = (*Solax)(nil) | ||
|
||
// TotalEnergy implements the api.MeterEnergy interface | ||
func (wb *Solax) TotalEnergy() (float64, error) { | ||
b, err := wb.conn.ReadInputRegisters(solaxRegTotalEnergy, 2) | ||
if err != nil { | ||
return 0, err | ||
} | ||
|
||
return float64(binary.BigEndian.Uint32(b)) / 10, err | ||
} | ||
|
||
var _ api.PhaseCurrents = (*Solax)(nil) | ||
|
||
// Currents implements the api.PhaseCurrents interface | ||
func (wb *Solax) Currents() (float64, float64, float64, error) { | ||
return wb.getPhaseValues(solaxRegCurrents) | ||
} | ||
|
||
var _ api.PhaseVoltages = (*Solax)(nil) | ||
|
||
// Voltages implements the api.PhaseVoltages interface | ||
func (wb *Solax) Voltages() (float64, float64, float64, error) { | ||
return wb.getPhaseValues(solaxRegVoltages) | ||
} | ||
|
||
var _ api.PhaseSwitcher = (*Solax)(nil) | ||
|
||
// Phases1p3p implements the api.PhaseSwitcher interface | ||
func (wb *Solax) Phases1p3p(phases int) error { | ||
var u uint16 | ||
|
||
if phases == 1 { | ||
u = 1 | ||
} | ||
|
||
_, err := wb.conn.WriteSingleRegister(solaxRegPhases, u) | ||
|
||
return err | ||
} |
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,26 @@ | ||
template: solax | ||
products: | ||
- brand: Solax | ||
description: | ||
generic: X3-EVC | ||
- brand: Tigo | ||
description: | ||
generic: GO EV Charger | ||
- brand: Qcells | ||
description: | ||
generic: Q.HOME EDRIVE A | ||
capabilities: ["mA", "1p3p"] | ||
requirements: | ||
evcc: ["sponsorship"] | ||
description: | ||
de: Die Wallbox muss sich im Modus "Schnell" befinden und vom Wechselrichtersystem entkoppelt sein. | ||
en: The charger must be in “Fast” mode and decoupled from the inverter system. | ||
params: | ||
- name: modbus | ||
choice: ["rs485"] | ||
baudrate: 9600 | ||
comset: 8N1 | ||
id: 70 | ||
render: | | ||
type: solax | ||