150 changes: 22 additions & 128 deletions src/EnergyPlus/GroundHeatExchangers.cc
Original file line number Diff line number Diff line change
Expand Up @@ -189,145 +189,39 @@ namespace GroundHeatExchangers {
slinkyGLHE.deallocate();
}

void
SimGroundHeatExchangers(
int const typeNum,
std::string const & name,
int & compIndex,
bool const EP_UNUSED( runFlag ),
bool const EP_UNUSED( firstIteration ),
bool const initLoopEquip
)
{
// SUBROUTINE INFORMATION:
// AUTHOR: Dan Fisher
// DATE WRITTEN: August, 2000
// MODIFIED Arun Murugappan
// RE-ENGINEERED na

// PURPOSE OF THIS SUBROUTINE:
// mananges the simulation of the vertical closed-loop ground heat
// exchangers (GLHE) model

// METHODOLOGY EMPLOYED:

// REFERENCES:
// Eskilson, P. 'Thermal Analysis of Heat Extraction Boreholes' Ph.D. Thesis:
// Dept. of Mathematical Physics, University of Lund, Sweden, June 1987.
// Yavuzturk, C., J.D. Spitler. 1999. 'A Short Time Step Response Factor Model
// for Vertical Ground Loop Heat Exchangers. ASHRAE Transactions. 105(2): 475-485.

// USE STATEMENTS:

// Using/Aliasing
using InputProcessor::FindItemInList;

// Locals
// SUBROUTINE ARGUMENT DEFINITIONS:

// SUBROUTINE PARAMETER DEFINITIONS:
// na

// INTERFACE BLOCK SPECIFICATIONS:
// na

// DERIVED TYPE DEFINITIONS:
// na

// SUBROUTINE LOCAL VARIABLE DECLARATIONS:
void GLHEBase::onInitLoopEquip( const PlantLocation & EP_UNUSED( calledFromLocation ) ) {
this->initGLHESimVars();
}

int GLHENum;
void GLHEBase::simulate( const PlantLocation & EP_UNUSED(calledFromLocation), bool const EP_UNUSED(FirstHVACIteration), Real64 & EP_UNUSED( CurLoad ) ) {
this->initGLHESimVars();
this->calcGroundHeatExchanger();
this->updateGHX();
}

//GET INPUT
PlantComponent * GLHEBase::factory( int const objectType, std::string objectName ) {
if ( GetInput ) {
GetGroundHeatExchangerInput();
GetInput = false;
}

if ( typeNum == DataPlant::TypeOf_GrndHtExchgVertical ) {

// Find the correct GLHE
if ( compIndex == 0 ) {
Array1D< std::string > tmpNames( numVerticalGLHEs );
for ( int i = 1; i <= numVerticalGLHEs; ++i ) {
tmpNames( i ) = verticalGLHE( i ).Name;
}
GLHENum = FindItemInList( name, tmpNames, numVerticalGLHEs );
if ( GLHENum == 0 ) {
ShowFatalError( "SimGroundHeatExchangers: Unit not found=" + name );
}
compIndex = GLHENum;
} else {
GLHENum = compIndex;
if ( GLHENum > numVerticalGLHEs || GLHENum < 1 ) {
ShowFatalError( "SimGroundHeatExchangers: Invalid compIndex passed=" + TrimSigDigits( GLHENum ) + ", Number of Units=" + TrimSigDigits( numVerticalGLHEs ) + ", Entered Unit name=" + name );
}
if ( checkEquipName( GLHENum ) ) {
if ( name != verticalGLHE( GLHENum ).Name ) {
ShowFatalError( "SimGroundHeatExchangers: Invalid compIndex passed=" + TrimSigDigits( numVerticalGLHEs ) + ", Unit name=" + name + ", stored Unit name for that index=" + verticalGLHE( GLHENum ).Name );
}
checkEquipName( GLHENum ) = false;
if ( objectType == DataPlant::TypeOf_GrndHtExchgVertical ) {
for ( auto & ghx : verticalGLHE ) {
if ( ghx.Name == objectName ) {
return &ghx;
}
}

auto & thisGLHE( verticalGLHE( GLHENum ) );

if ( initLoopEquip ) {
thisGLHE.initGLHESimVars();
return;
}

// Initialize HX
thisGLHE.initGLHESimVars();

// Simulat HX
thisGLHE.calcGroundHeatExchanger();

// Update HX Report Vars
thisGLHE.updateGHX();

} else if ( typeNum == DataPlant::TypeOf_GrndHtExchgSlinky ) {

// Find the correct GLHE
if ( compIndex == 0 ) {
Array1D< std::string > tmpNames( numSlinkyGLHEs );
for ( int i = 1; i <= numSlinkyGLHEs; ++i ) {
tmpNames( i ) = slinkyGLHE( i ).Name;
}
GLHENum = FindItemInList( name, tmpNames, numSlinkyGLHEs );
if ( GLHENum == 0 ) {
ShowFatalError( "SimGroundHeatExchangers: Unit not found=" + name );
}
compIndex = GLHENum;
} else {
GLHENum = compIndex;
if ( GLHENum > numSlinkyGLHEs || GLHENum < 1 ) {
ShowFatalError( "SimGroundHeatExchangers: Invalid compIndex passed=" + TrimSigDigits( GLHENum ) + ", Number of Units=" + TrimSigDigits( numSlinkyGLHEs ) + ", Entered Unit name=" + name );
} else if ( objectType == DataPlant::TypeOf_GrndHtExchgSlinky ) {
for ( auto & ghx : slinkyGLHE ) {
if ( ghx.Name == objectName ) {
return &ghx;
}
if ( checkEquipName( GLHENum ) ) {
if ( name != slinkyGLHE( GLHENum ).Name ) {
ShowFatalError( "SimGroundHeatExchangers: Invalid compIndex passed=" + TrimSigDigits( numSlinkyGLHEs ) + ", Unit name=" + name + ", stored Unit name for that index=" + slinkyGLHE( GLHENum ).Name );
}
checkEquipName( GLHENum ) = false;
}
}

auto & thisGLHE( slinkyGLHE( GLHENum ) );

if ( initLoopEquip ) {
thisGLHE.initGLHESimVars();
return;
}

// Initialize HX
thisGLHE.initGLHESimVars();

// Simulate HX
thisGLHE.calcGroundHeatExchanger();

// Update HX Report Vars
thisGLHE.updateGHX();
}
// If we didn't find it, fatal
ShowFatalError( "Ground Heat Exchanger Factory: Error getting inputs for GHX named: " + objectName );
// Shut up the compiler
return nullptr;
}

//******************************************************************************
Expand Down Expand Up @@ -2245,7 +2139,7 @@ namespace GroundHeatExchangers {
InitComponentNodes( 0.0, designMassFlow, inletNodeNum, outletNodeNum, loopNum, loopSideNum, branchNum, compNum );

lastQnSubHr = 0.0;
Node( inletNodeNum ).Temp = this->groundTempModel->getGroundTempAtTimeInSeconds( coilDepth, CurTime );
Node( inletNodeNum ).Temp = this->groundTempModel->getGroundTempAtTimeInSeconds( coilDepth, CurTime );
Node( outletNodeNum ).Temp = this->groundTempModel->getGroundTempAtTimeInSeconds( coilDepth, CurTime );

// zero out all history arrays
Expand Down
21 changes: 9 additions & 12 deletions src/EnergyPlus/GroundHeatExchangers.hh
Original file line number Diff line number Diff line change
Expand Up @@ -66,6 +66,7 @@
#include <EnergyPlus.hh>
#include <DataGlobals.hh>
#include <GroundTemperatureModeling/GroundTemperatureModelManager.hh>
#include <PlantComponent.hh>

namespace EnergyPlus {

Expand All @@ -87,10 +88,10 @@ namespace GroundHeatExchangers {

// Types

struct GLHEBase
struct GLHEBase : PlantComponent
{
// Destructor
virtual
virtual
~GLHEBase()
{}

Expand Down Expand Up @@ -210,6 +211,12 @@ namespace GroundHeatExchangers {
virtual void
getAnnualTimeConstant()=0;

void onInitLoopEquip( const PlantLocation & EP_UNUSED( calledFromLocation ) );

void simulate( const PlantLocation & calledFromLocation, bool const FirstHVACIteration, Real64 & CurLoad );

static PlantComponent * factory( int const objectType, std::string objectName );

};

struct GLHEVert:GLHEBase
Expand Down Expand Up @@ -403,16 +410,6 @@ namespace GroundHeatExchangers {
void
clear_state();

void
SimGroundHeatExchangers(
int const GLHETypeNum,
std::string const & name,
int & compIndex,
bool const runFlag,
bool const firstIteration,
bool const initLoopEquip
);

void
GetGroundHeatExchangerInput();

Expand Down
21 changes: 3 additions & 18 deletions src/EnergyPlus/PlantLoopEquip.cc
Original file line number Diff line number Diff line change
Expand Up @@ -235,7 +235,6 @@ namespace PlantLoopEquip {
using ICEngineElectricGenerator::SimICEPlantHeatRecovery;
using CTElectricGenerator::SimCTPlantHeatRecovery;
using MicroturbineElectricGenerator::SimMTPlantHeatRecovery;
using SurfaceGroundHeatExchanger::SimSurfaceGroundHeatExchanger;
using PondGroundHeatExchanger::SimPondGroundHeatExchanger;

using PlantLoadProfile::SimulatePlantProfile;
Expand Down Expand Up @@ -793,19 +792,10 @@ namespace PlantLoopEquip {
} else if ( GeneralEquipType == GenEquipTypes_GroundHeatExchanger ) {

if ( EquipTypeNum == TypeOf_GrndHtExchgVertical ) { // 'GROUND HEAT EXCHANGER:VERTICAL'
//sim_component.compPtr->simulate( sim_component_location, FirstHVACIteration, CurLoad );
GroundHeatExchangers::SimGroundHeatExchangers( sim_component.TypeOf_Num, sim_component.Name, EquipNum, RunFlag, FirstHVACIteration, InitLoopEquip ); //DSU

if ( InitLoopEquip ) {
sim_component.CompNum = EquipNum;
}
sim_component.compPtr->simulate( sim_component_location, FirstHVACIteration, CurLoad );

} else if ( EquipTypeNum == TypeOf_GrndHtExchgSurface ) { // 'GROUND HEAT EXCHANGER:SURFACE'
SimSurfaceGroundHeatExchanger( sim_component.Name, EquipNum, FirstHVACIteration, RunFlag, InitLoopEquip ); //DSU

if ( InitLoopEquip ) {
sim_component.CompNum = EquipNum;
}
sim_component.compPtr->simulate( sim_component_location, FirstHVACIteration, CurLoad );

} else if ( EquipTypeNum == TypeOf_GrndHtExchgPond ) { // 'GROUND HEAT EXCHANGER:POND'
SimPondGroundHeatExchanger( sim_component.Name, EquipNum, FirstHVACIteration, RunFlag, InitLoopEquip, MaxLoad, MinLoad, OptLoad ); //DSU
Expand All @@ -826,12 +816,7 @@ namespace PlantLoopEquip {
}

} else if ( EquipTypeNum == TypeOf_GrndHtExchgSlinky ) { // 'GROUND HEAT EXCHANGER:SLINKY'
//sim_component.compPtr->simulate( sim_component_location, FirstHVACIteration, CurLoad );
GroundHeatExchangers::SimGroundHeatExchangers( sim_component.TypeOf_Num, sim_component.Name, EquipNum, RunFlag, FirstHVACIteration, InitLoopEquip );

if ( InitLoopEquip ) {
sim_component.CompNum = EquipNum;
}
sim_component.compPtr->simulate( sim_component_location, FirstHVACIteration, CurLoad );


}
Expand Down
6 changes: 4 additions & 2 deletions src/EnergyPlus/PlantManager.cc
Original file line number Diff line number Diff line change
Expand Up @@ -93,6 +93,7 @@
#include <ReportSizingManager.hh>
#include <ScheduleManager.hh>
#include <SetPointManager.hh>
#include <SurfaceGroundHeatExchanger.hh>
#include <SystemAvailabilityManager.hh>
#include <UtilityRoutines.hh>

Expand Down Expand Up @@ -1020,11 +1021,12 @@ namespace PlantManager {
this_comp.TypeOf_Num = TypeOf_GrndHtExchgVertical;
this_comp.GeneralEquipType = GenEquipTypes_GroundHeatExchanger;
this_comp.CurOpSchemeType = UncontrolledOpSchemeType;
//this_comp.compPtr = GroundHeatExchangers::GLHEBase::factory( TypeOf_GrndHtExchgVertical, CompNames( CompNum ) );
this_comp.compPtr = GroundHeatExchangers::GLHEBase::factory( TypeOf_GrndHtExchgVertical, CompNames( CompNum ) );
} else if ( SameString( this_comp_type, "GroundHeatExchanger:Surface" ) ) {
this_comp.TypeOf_Num = TypeOf_GrndHtExchgSurface;
this_comp.GeneralEquipType = GenEquipTypes_GroundHeatExchanger;
this_comp.CurOpSchemeType = UncontrolledOpSchemeType;
this_comp.compPtr = SurfaceGroundHeatExchanger::SurfaceGroundHeatExchangerData::factory( TypeOf_GrndHtExchgSurface, CompNames( CompNum ) );
} else if ( SameString( this_comp_type, "GroundHeatExchanger:Pond" ) ) {
this_comp.TypeOf_Num = TypeOf_GrndHtExchgPond;
this_comp.GeneralEquipType = GenEquipTypes_GroundHeatExchanger;
Expand All @@ -1033,7 +1035,7 @@ namespace PlantManager {
this_comp.TypeOf_Num = TypeOf_GrndHtExchgSlinky;
this_comp.GeneralEquipType = GenEquipTypes_GroundHeatExchanger;
this_comp.CurOpSchemeType = UncontrolledOpSchemeType;
//this_comp.compPtr = GroundHeatExchangers::GLHEBase::factory( TypeOf_GrndHtExchgSlinky, CompNames( CompNum ) );
this_comp.compPtr = GroundHeatExchangers::GLHEBase::factory( TypeOf_GrndHtExchgSlinky, CompNames( CompNum ) );
} else if ( SameString( this_comp_type, "Chiller:Electric:EIR" ) ) {
this_comp.TypeOf_Num = TypeOf_Chiller_ElectricEIR;
this_comp.GeneralEquipType = GenEquipTypes_Chiller;
Expand Down