1.9.5

Compare
Choose a tag to compare
@proddy proddy released this 30 Apr 08:50

[1.9.5] 30-04-2020

Added

  • Solar Module SM200 support
  • Support writing to Junkers FR100 thermostats
  • Support writing to RC100, Moduline 1000/1010 thermostats
  • MM10 Mixing module support (thanks @MichaelDvP)
  • MM200 warm water circuits (#315)
  • Support for Moduline 200 and Sieger ES72 thermostats
  • First implementation of writing to generic Junker Thermostats (thanks @Neonox31)
  • Added model type (Buderus, Sieger, Junkers, Nefit, Bosch, Worcester) to device names
  • set master_thermostat <product id> to choose with thermostat is master when there are multiple on the bus
  • boiler wwonetime command from Telnet
  • set bus_id <ID> to support multiple EMS-ESP circuits. Default is 0x0B to mimic a service key.
  • mqtt_nestedjson option to disable multiple data records being nested into a single JSON string
  • MQTT publish messages are queued and gracefully published every second to avoid TCP blocks
  • Added features to WW messages (0x33, 0x34) to improve WW monitoring. (PR#338 by @ypaindaveine)
  • Added mixing log and stub for EMS type 0xAC (PR#338 by @ypaindaveine)
  • Added Thermostat retrieving settings (0xA5) (validated on RC30N) with MQTT support (thanks Yves @ypaindaveine. See #352)
  • Merged with PR #366 from @MichaelDvP fixing RC20 and MM50

Fixed

  • set boiler warm water temp on Junkers/Bosch HT3
  • fixed detection of the Moduline 400 thermostat
  • RC35 setting temperature also forces the current select temp to change, irrespective of the mode

Changed

  • improved MQTT publishing to stop network flooding. publish_time of -1 is no publish, 0 is automatic otherwise its a time interval
  • External sensors (like Dallas DS18*) are sent as a nested MQTT topic including their unqiue identifier
  • mqttlog console command renamed to mqttqueue to only show the current publish queue
  • status payload on start-up shows the IP and Version of EMS-ESP
  • thermostat mode takes a string like manual,auto,heat,day,night,eco,comfort,holiday,nofrost
  • thermostat temp also takes a mode string, e.g. thermostat temp 20 heat
  • queue renamed to txqueue

Removed

  • autodetect scan. Replaced with devices scan and devices scan+ for deep scanning
  • mqttlog all and showing MQTT log in the web interface - no point showing history of previous mqtt publishes in ESP's precious memory. For debugging I recommend using MQTT Explorer or another external tool.