The following changes are included in the Release.
End User Release Notes:
- Update eICR 3.1 generator to remove duplicate social history sections causing a schematron error. (#885)
- Added support for NPI as part of the custodian in the eICR header, the NPI will be populated when available. (#870)
- Added Lab Interpretation code, Specimen collection date and reference ranges for lab results to the Lab Results Narrative when available (#868)
- Added Medication Dosage details to the section narrative when available (#853)
EHR Vendor Specific Release Notes:
- Add index for performance improvements for launchPatient API. (#888)
- Update DB scripts documentation and scripts to automate migrations between baselines for 3.X (#894)
- Update error handling to enable EHR vendors to detect failures and reprocess the same encounter and patient (#895)
Tickets Closed with no changes as they are present in the previous baselines or not being addressed: (Relevant to EHR vendors)
- ICD10 based trigger codes get annotated with sdtc:valueset and stdc:valuesetversion when it results in a trigger code. (#869)