Hi,
could you pls send me your drawing diagram, or pls get me on skype :
nandar.mtn
regards
Nandar
…On Thu, 1 Aug 2019, 21:43 MarkOude, ***@***.***> wrote:
Hello,
I have a 300W Solar Cell laying around and I want to use it wit yout
MPPT-Design.
The problem: it has about 40V maximum.
Where is the 25V limit, I mean the mosfets can handle 55V...
Is the Problem D2 ( the MOSFET-Diver ), because it is directly conneted to
the solarcell Voltage?
A Solve would be to just use a LM2596 Buck converter and drive D2 with
that voltage..
Or is it somewhere else?
Sorry for my (hopefully not so) bad English.
Gerne auch in Deutsch ;-)
—
You are receiving this because you are subscribed to this thread.
Reply to this email directly, view it on GitHub
<#15?email_source=notifications&email_token=AFNZPESGBVHZRKTH4KTXITDQCLY7XA5CNFSM4IIRNOBKYY3PNVWWK3TUL52HS4DFUVEXG43VMWVGG33NNVSW45C7NFSM4HC27FRQ>,
or mute the thread
<https://github.com/notifications/unsubscribe-auth/AFNZPEQFOVI43W3VQUW5WWTQCLY7XANCNFSM4IIRNOBA>
.
|
Hi,
This project is not fully functional. You can go through the comments
section, for modification. You can ask your question there.
Regards
Debasish
…On Thu, Aug 1, 2019, 11:38 PM MarkOude ***@***.***> wrote:
[image: mppt controller_schema_with-LM2596]
<https://user-images.githubusercontent.com/9406959/62316138-211b2800-b497-11e9-8fbc-23da2e486011.png>
Hi,
I thought of something like this...
I don't know if i could run this thing with that schematic on 40V or if
something else would be damaged at this voltage level or if it would work
flawlessly fine...
best regards
Mark
—
You are receiving this because you are subscribed to this thread.
Reply to this email directly, view it on GitHub
<#15?email_source=notifications&email_token=ABSRQPQK5RVCBAUOIKUBMOLQCMRARA5CNFSM4IIRNOBKYY3PNVWWK3TUL52HS4DFVREXG43VMVBW63LNMVXHJKTDN5WW2ZLOORPWSZGOD3LN3II#issuecomment-517397921>,
or mute the thread
<https://github.com/notifications/unsubscribe-auth/ABSRQPRSL7O4E32JJNJ5HQTQCMRARANCNFSM4IIRNOBA>
.
|
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Hello,
I have a 300W Solar Cell laying around and I want to use it wit yout MPPT-Design.
The problem: it has about 40V maximum.
Where is the 25V limit, I mean the mosfets can handle 55V...
Is the Problem D2 ( the MOSFET-Diver ), because it is directly conneted to the solarcell Voltage?
A Solve would be to just use a LM2596 Buck converter and drive D2 with that voltage..
Or is it somewhere else?
Sorry for my (hopefully not so) bad English.
Gerne auch in Deutsch ;-)