kCanRebin is replaced with SetCanExtend in online beamspot code for dqm #9416
kCanRebin is replaced with SetCanExtend in online beamspot code for dqm #9416
Conversation
A new Pull Request was created by @sushilchauhan for CMSSW_7_4_X. kCanRebin is replaced with SetCanExtend in online beamspot code for dqm It involves the following packages: DQM/BeamMonitor @cmsbuild, @danduggan, @deguio can you please review it and eventually sign? Thanks. |
+1 |
@sushilchauhan |
This pull request is fully signed and it will be integrated in one of the next CMSSW_7_4_X IBs unless changes or unless it breaks tests. This pull request requires discussion in the ORP meeting before it's merged. @davidlange6, @Degano, @smuzaffar |
This pull request is fully signed and it will be integrated in one of the next CMSSW_7_4_X IBs unless changes (tests are also fine). This pull request requires discussion in the ORP meeting before it's merged. @davidlange6, @Degano, @smuzaffar |
Comparison is ready There are some workflows for which there are errors in the baseline: |
This pull request is fully signed and it will be integrated in one of the next CMSSW_7_4_X IBs unless changes (tests are also fine). This pull request requires discussion in the ORP meeting before it's merged. @davidlange6, @Degano, @smuzaffar |
…pre5 replaced kCanRebin with SetCanExtend for beamspot code for online DQM as done in PR #9416
+1 |
kCanRebin is replaced with SetCanExtend in online beamspot code for dqm
This PR should not have been merged into 7_4_ROOT5_X. It is ROOT6 specific. It breaks 7_4_ROOT5_X. |
kCanRebin is replaced with SetCanExtend in online BeamSpot code for DQM to work properly in 74x