[FIX] make MEG section headings and ToC consistent to the EEG and iEEG specs #181

Merged
merged 2 commits into from
Apr 3, 2019
Merged
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
33 changes: 17 additions & 16 deletions src/04-modality-specific-files/02-magnetoencephalography.md
Original file line number Diff line number Diff line change
Expand Up @@ -352,7 +352,7 @@ For more information on typical coordinate systems for MEG-MRI coregistration:
or:
[http://neuroimage.usc.edu/brainstorm/CoordinateSystems](http://neuroimage.usc.edu/brainstorm/CoordinateSystems)

### Landmark photos (`*_photo.jpg`)
## Landmark photos (`*_photo.jpg`)

Photos of the anatomical landmarks and/or head localization coils
(`*_photo.jpg`)
Expand All @@ -378,7 +378,7 @@ actual anatomical nasion: `sub-0001_ses-001_acq-NAS_photo.jpg`

![placement of NAS fiducial](images/sub-0001_ses-001_acq-NAS_photo.jpg "placement of NAS fiducial")

### 3-D head point /electrode locations
## Head shape and electrode description (`*_headshape.<ext>`)

Template:

Expand All @@ -391,12 +391,12 @@ sub-<label>/

This file is RECOMMENDED.

The 3-D locations of head points and/or EEG electrode locations can be digitized
and stored in separate files. The `*_acq-<label>` can be used when more than one
type of digitization in done for a session, for example when the head points are
in a separate file from the EEG locations. These files are stored in the
specific format of the 3-D digitizer’s manufacturer (see
[Appendix VI](../99-appendices/06-meg-file-formats.md)).
The 3-D locations of points that describe the head shape and/or EEG
electrode locations can be digitized and stored in separate files. The
`*_acq-<label>` can be used when more than one type of digitization in done for
a session, for example when the head points are in a separate file from the EEG
locations. These files are stored in the specific format of the 3-D digitizer’s
manufacturer (see [Appendix VI](../99-appendices/06-meg-file-formats.md)).

Example:

Expand All @@ -411,15 +411,16 @@ Note that the `*_headshape` file(s) is shared by all the runs and tasks in a
session. If the subject needs to be taken out of the scanner and the head-shape
has to be updated, then for MEG it could be considered to be a new session.

### Empty-room files (`sub-emptyroom`)
## Empty-room MEG recordings

Empty-room MEG files capture the environment and system noise. Their collection
is RECOMMENDED, before/during/after each session. This data is stored inside a
subject folder named `sub-emptyroom`. The `session label` SHOULD be that of the
date of the empty-room recording (e.g. `ses-YYYYMMDD`). The `scans.tsv` file
containing the date/time of the acquisition SHOULD also be included. Hence,
users will be able to retrieve the empty-room recording that best matches a
particular session with a participant, based on date/time of recording.
Empty-room MEG recordings capture the environment and system noise. Their
collection is RECOMMENDED, before/during/after each session. This data is stored
inside a subject folder named `sub-emptyroom`. The `session label` SHOULD be
that of the date of the empty-room recording (e.g. `ses-YYYYMMDD`). The
`scans.tsv` file containing the date/time of the acquisition SHOULD also be
included. Hence, users will be able to retrieve the empty-room recording that
best matches a particular session with a participant, based on date/time of
recording.

Example:

Expand Down