Relative Humidity compensated wrong #218

Closed
airgradienthq opened this issue Aug 25, 2024 · 0 comments
Closed

Relative Humidity compensated wrong #218

airgradienthq opened this issue Aug 25, 2024 · 0 comments

Comments

@airgradienthq
Copy link
Owner

O-1PPT Model

[1] PM1 ug/m3: 1
[1] PM2.5 ug/m3: 3
[1] PM10 ug/m3: 5
[1] PM3.0 Count: 0
[1] Temperature in C: 25.10
[1] Relative Humidity: 41
[1] Temperature compensated in C: 24.53
[1] Relative Humidity compensated: 58.959000

[2] PM1 ug/m3: 0
[2] PM2.5 ug/m3: 2
[2] PM10 ug/m3: 3
[2] PM3.0 Count: 0
[2] Temperature in C: 25.30
[2] Relative Humidity: 41
[2] Temperature compensated in C: 24.77
[2] Relative Humidity compensated: -2147483648

Something looks wrong with RH Compensated

(fw 3.1.5)