hydro inflow unit conversion corrected #254
Merged
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
In hydro.py, line 103
nhours = (distances * (flowspeed * 3.6) + 0.5).astype(int)
should be
nhours = ((distances * 1000) / (flowspeed * 3600) + 0.5).astype(int)
or
nhours = (distances / (flowspeed * 3.6) + 0.5).astype(int)