Error trying to Autosize OS:WaterHeater:Mixed: Wrap WaterHeater:Sizing in OpenStudio #669
Comments
No I don't think you are doing anything wrong. To be honest I didn't know there was a water heater sizing object. |
I'm seeing this in 1.6.0 and 1.6.3. |
+1 in 1.10.2 |
@kbenne any thoughts on this? |
My thought is we need to at WaterHeaterSizing, but I honestly don't have it in my queue yet. |
Could you remove the autosizing option from the water heater tank volume and tank capacity in the interface until you have time to fix the problem (which I think is telling EnergyPlus which of the six autosizing options to use)? |
It's unrelated to E+ 9.0.0, but I was touching the IDD so needed to rebuilt IddFactory anyways
Fix #669 - Wrap E+ WaterHeater:Sizing object
When I drop in a water heater it starts as 100 gallon tank volume, and a capacity of about 2,800,000 Btu/hr.
The capacity seems large, when I tried to run after changing it to autosize I get the following error. Am I doing something wrong, or is there no way to autosize this object?
** Warning ** Water heater named OS:WATERHEATER:MIXEDhas heater capacity set to AUTOSIZE but it is missing associated WaterHeater:Sizing object
** Fatal ** Errors found in water heater input. Preceding condition causes termination.
The text was updated successfully, but these errors were encountered: