Setup heat recovery flag for multispeed DX coils in AirloopHVAC:UnitarySystem #5471

Merged
Show file tree
Hide file tree
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
4 changes: 2 additions & 2 deletions src/EnergyPlus/HVACMultiSpeedHeatPump.cc
Original file line number Diff line number Diff line change
Expand Up @@ -1265,12 +1265,12 @@ namespace HVACMultiSpeedHeatPump {
if ( MSHeatPump( MSHPNum ).DesignHeatRecFlowRate > 0.0 ) {
MSHeatPump( MSHPNum ).HeatRecActive = true;
MSHeatPump( MSHPNum ).DesignHeatRecMassFlowRate = RhoH2O( InitConvTemp ) * MSHeatPump( MSHPNum ).DesignHeatRecFlowRate;
MSHeatPump( MSHPNum ).HeatRecInletNodeNum = GetOnlySingleNode( Alphas( 16 ), ErrorsFound, "MSHP Heat receovery", Alphas( 1 ), NodeType_Water, NodeConnectionType_Inlet, 3, ObjectIsNotParent );
MSHeatPump( MSHPNum ).HeatRecInletNodeNum = GetOnlySingleNode( Alphas( 16 ), ErrorsFound, CurrentModuleObject, Alphas( 1 ), NodeType_Water, NodeConnectionType_Inlet, 3, ObjectIsNotParent );
if ( MSHeatPump( MSHPNum ).HeatRecInletNodeNum == 0 ) {
ShowSevereError( CurrentModuleObject + ", \"" + MSHeatPump( MSHPNum ).Name + "\", Missing " + cAlphaFields( 16 ) + '.' );
ErrorsFound = true;
}
MSHeatPump( MSHPNum ).HeatRecOutletNodeNum = GetOnlySingleNode( Alphas( 17 ), ErrorsFound, "MSHP Heat receovery", Alphas( 1 ), NodeType_Water, NodeConnectionType_Outlet, 3, ObjectIsNotParent );
MSHeatPump( MSHPNum ).HeatRecOutletNodeNum = GetOnlySingleNode( Alphas( 17 ), ErrorsFound, CurrentModuleObject, Alphas( 1 ), NodeType_Water, NodeConnectionType_Outlet, 3, ObjectIsNotParent );
if ( MSHeatPump( MSHPNum ).HeatRecOutletNodeNum == 0 ) {
ShowSevereError( CurrentModuleObject + ", \"" + MSHeatPump( MSHPNum ).Name + "\", Missing " + cAlphaFields( 17 ) + '.' );
ErrorsFound = true;
Expand Down
13 changes: 10 additions & 3 deletions src/EnergyPlus/HVACUnitarySystem.cc
Original file line number Diff line number Diff line change
Expand Up @@ -2745,6 +2745,7 @@ namespace HVACUnitarySystem {
using UserDefinedComponents::GetUserDefinedCoilAirInletNode;
using UserDefinedComponents::GetUserDefinedCoilAirOutletNode;
using PackagedThermalStorageCoil::GetTESCoilCoolingCapacity;
using DXCoils::SetMSHPDXCoilHeatRecoveryFlag;

// Locals
// SUBROUTINE ARGUMENT DEFINITIONS:
Expand Down Expand Up @@ -5819,11 +5820,17 @@ namespace HVACUnitarySystem {
UnitarySystem( UnitarySysNum ).HeatRecActive = true;
errFlag = false;
if ( ! lAlphaBlanks( iHRWaterInletNodeAlphaNum ) && ! lAlphaBlanks( iHRWaterOutletNodeAlphaNum ) ) {
UnitarySystem( UnitarySysNum ).HeatRecoveryInletNodeNum = GetOnlySingleNode( Alphas( iHRWaterInletNodeAlphaNum ), errFlag, "Unitary System Heat receovery", Alphas( iNameAlphaNum ), NodeType_Water, NodeConnectionType_Inlet, 3, ObjectIsParent );
UnitarySystem( UnitarySysNum ).HeatRecoveryOutletNodeNum = GetOnlySingleNode( Alphas( iHRWaterOutletNodeAlphaNum ), errFlag, "Unitary System Heat receovery", Alphas( iNameAlphaNum ), NodeType_Water, NodeConnectionType_Inlet, 3, ObjectIsParent );
UnitarySystem( UnitarySysNum ).HeatRecoveryInletNodeNum = GetOnlySingleNode( Alphas( iHRWaterInletNodeAlphaNum ), errFlag, CurrentModuleObject, Alphas( iNameAlphaNum ), NodeType_Water, NodeConnectionType_Inlet, 3, ObjectIsNotParent );
UnitarySystem( UnitarySysNum ).HeatRecoveryOutletNodeNum = GetOnlySingleNode( Alphas( iHRWaterOutletNodeAlphaNum ), errFlag, CurrentModuleObject, Alphas( iNameAlphaNum ), NodeType_Water, NodeConnectionType_Outlet, 3, ObjectIsNotParent );

TestCompSet( CurrentModuleObject, Alphas( iNameAlphaNum ), Alphas( iHRWaterInletNodeAlphaNum ), Alphas( iHRWaterOutletNodeAlphaNum ), "Unitary System Heat receovery Nodes" );
TestCompSet( CurrentModuleObject, Alphas( iNameAlphaNum ), Alphas( iHRWaterInletNodeAlphaNum ), Alphas( iHRWaterOutletNodeAlphaNum ), "Unitary System Heat Recovery Nodes" );

if ( UnitarySystem( UnitarySysNum ).CoolingCoilType_Num == CoilDX_MultiSpeedCooling ) {
SetMSHPDXCoilHeatRecoveryFlag( UnitarySystem( UnitarySysNum ).CoolingCoilIndex );
}
if ( UnitarySystem( UnitarySysNum ).HeatingCoilType_Num == CoilDX_MultiSpeedHeating ) {
SetMSHPDXCoilHeatRecoveryFlag( UnitarySystem( UnitarySysNum ).HeatingCoilIndex );
}
if ( errFlag ) {
ShowContinueError( "Occurs in " + CurrentModuleObject + " = " + UnitarySystem( UnitarySysNum ).Name );
ErrorsFound = true;
Expand Down
Loading