Expand Up @@ -97,6 +97,9 @@ \subsubsection{SpaceHVAC:ZoneEquipmentMixer Adjustments}\label{space-hvac-zoneeq

After all of the zone HVAC equipment is simulated, the flow rates on the space outlet nodes are set to the space fraction times the zone equipment inlet node flow rate.

\subsubsection{SpaceHVAC:ZoneReturnMixer Adjustments}\label{space-hvac-zoneretmixer-adjustments}
When a SpaceHVAC:ZoneReturnMixer is used, after zone-level return node flow rates are set, the space return node flow rates are set. The space flow rates are set based on the same method used for zones (sum of inlet flows minus sum of exhaust flows). Then the space flow rates are adjusted proportionately so the sum is equal to the previously determined zone-level return node flow rate. Then the conditions on the zone return nodes are set to the combined space outlet node conditions weighted by the space return node flow rates.

\subsection{References}\label{references-043}

Ceylan, H. T., and G. E. Myers. 1980. Long-time Solutions to Heat Conduction Transients with Time-Dependent Inputs. ASME Journal of Heat Transfer, Volume 102, No. 1, pp.~115-120.
Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -243,6 +243,12 @@ \subsubsection{EndZoneSizingCalc}\label{endzonesizingcalc}

If \emph{heating design air flow method} is \emph{flow/zone}, then \emph{heating design air flow rate} will be used for the design max heating air flow rate. If \emph{heating design air flow method} is \emph{design day}, then the design day calculation will set the design max heating air flow rate. If \emph{heating design air flow method} is \emph{design day with limit}, then the maximum from \emph{heating max flow per area}, \emph{heating max flow} and \emph{heating max flow fraction} will set an upper limit on the design max heating air flow rate. The design max heating air flow rate must always be \textgreater{} = the ventilation requirement. In each case, the outside airflow will be modified based on zone ventilation effectiveness specified in the zone sizing object.

\subsection{Space Sizing}\label{space-sizing}
When ZoneAirHeatBalanceAlgorithm ``Do Space Heat Balance for Sizing'' is ``Yes'', the same sizing calculations described above will be performed for each space that is part of a controlled zone, using the same thermostat setpoints as the parent zone. The space sizing results will be reported the same as zone sizing results (eio, table, and spsz outputs).

\subsection{NonCoincident Zone Sizing}\label{noncoincident-zone-sizing}
Sizing:Zone has an option for ``Type of Space Sum to Use'', ``Coincident'' or ``NonCoincident''. Coincident zone sizing (the default) is always calculated first, with all spaces in the zone lumped together. For ``NonCoincident'' zone sizing, if the zone contains more than one space, the zone sizing results will be overwritten using the sums and averages of the space sizing results. If all spaces for a given load type (heating or cooling) peak on the same design day, then that day will be reported as the zone peak day, otherwise the zone design day will be "N/A". The zone peak time will be determined by scanning the peak zone sequential loads which are calculated by summing the space peak day sequential loads.

\textbf{This concludes the calculation of the zone design flow rates and loads.}

\subsection{Air Terminal Unit Sizing}\label{air-terminal-unit-sizing}
Expand Down

4 comments on commit a2bf2e9

@nrel-bot
Copy link

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

SpacePart4Followup (mjwitte) - Win64-Windows-10-VisualStudio-16: OK (2874 of 2874 tests passed, 0 test warnings)

Build Badge Test Badge

@nrel-bot-2b
Copy link

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

SpacePart4Followup (mjwitte) - x86_64-Linux-Ubuntu-22.04-gcc-11.4: OK (3708 of 3709 tests passed, 1 test warnings)

Messages:\n

  • 2 tests had: EIO diffs.
  • 1 test had: Table big diffs.
  • 1 test had: Table small diffs.

Failures:\n

regression Test Summary

  • Passed: 812
  • Failed: 1

Build Badge Test Badge

@nrel-bot-2c
Copy link

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

SpacePart4Followup (mjwitte) - x86_64-Linux-Ubuntu-22.04-gcc-11.4-IntegrationCoverage-Debug: OK (797 of 797 tests passed, 0 test warnings)

Build Badge Test Badge Coverage Badge

@nrel-bot-2
Copy link

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

SpacePart4Followup (mjwitte) - x86_64-Linux-Ubuntu-22.04-gcc-11.4-UnitTestsCoverage-Debug: OK (2080 of 2080 tests passed, 0 test warnings)

Build Badge Test Badge Coverage Badge

Please sign in to comment.