plant sizing and reporting changes, new resizing
Browse files Browse the repository at this point in the history
green shoots at proving concept.  Boiler, electric chiller and pump
changes drafted.  5zoneAirCooled working to resize based HVAC Sizing
Simulation.
  • Loading branch information
EnergyArchmage committed Jan 18, 2015
1 parent f44f86f commit 80efac7
Show file tree
Hide file tree
Showing 9 changed files with 428 additions and 142 deletions.
10 changes: 5 additions & 5 deletions src/EnergyPlus/Boilers.cc
Original file line number Diff line number Diff line change
Expand Up @@ -195,9 +195,9 @@ namespace Boilers {

// Initialize Loop Equipment
if ( InitLoopEquip ) {
Boiler( BoilerNum ).IsThisSized = false;
// Boiler( BoilerNum ).IsThisSized = false;
InitBoiler( BoilerNum );
Boiler( BoilerNum ).IsThisSized = true;
// Boiler( BoilerNum ).IsThisSized = true;
SizeBoiler( BoilerNum );
MinCap = Boiler( BoilerNum ).NomCap * Boiler( BoilerNum ).MinPartLoadRat;
MaxCap = Boiler( BoilerNum ).NomCap * Boiler( BoilerNum ).MaxPartLoadRat;
Expand Down Expand Up @@ -531,7 +531,7 @@ namespace Boilers {
using DataPlant::TypeOf_Boiler_Simple;
using DataPlant::PlantFirstSizesOkayToFinalize;
using DataPlant::PlantFirstSizeCompleted;
using DataPlant::PlantReSizingNotComplete;
using DataPlant::PlantReSizingCompleted;
using DataPlant::LoopFlowStatus_NeedyIfLoopOn;
using DataPlant::SingleSetPoint;
using DataPlant::DualSetPointDeadBand;
Expand Down Expand Up @@ -586,7 +586,7 @@ namespace Boilers {
}

if ( MyEnvrnFlag( BoilerNum ) && BeginEnvrnFlag && ( PlantFirstSizesOkayToFinalize ) ) {
if ( ! PlantFirstSizeCompleted ) SizeBoiler( BoilerNum );
//if ( ! PlantFirstSizeCompleted ) SizeBoiler( BoilerNum );
rho = GetDensityGlycol( PlantLoop( Boiler( BoilerNum ).LoopNum ).FluidName, InitConvTemp, PlantLoop( Boiler( BoilerNum ).LoopNum ).FluidIndex, RoutineName );
Boiler( BoilerNum ).DesMassFlowRate = Boiler( BoilerNum ).VolFlowRate * rho;

Expand Down Expand Up @@ -667,7 +667,7 @@ namespace Boilers {
using namespace DataSizing;
using DataPlant::PlantLoop;
using DataPlant::PlantFirstSizesOkayToFinalize;
using DataPlant::PlantReSizingNotComplete;
using DataPlant::PlantReSizingCompleted;
using DataPlant::PlantSizesOkayToReport;
using FluidProperties::GetDensityGlycol;
using FluidProperties::GetSpecificHeatGlycol;
Expand Down
2 changes: 1 addition & 1 deletion src/EnergyPlus/DataPlant.cc
Original file line number Diff line number Diff line change
Expand Up @@ -348,7 +348,7 @@ namespace DataPlant {
int TotNumHalfLoops( 0 ); // number of half loops (2 * TotNumLoops)
bool PlantFirstSizeCompleted( false );
bool PlantFirstSizesOkayToFinalize( false ); // true if plant sizing is finishing and can save results
bool PlantReSizingNotComplete( false );
bool PlantReSizingCompleted( false );
bool PlantSizesOkayToReport( false );
bool AnyEMSPlantOpSchemesInModel( false );

Expand Down
2 changes: 1 addition & 1 deletion src/EnergyPlus/DataPlant.hh
Original file line number Diff line number Diff line change
Expand Up @@ -336,7 +336,7 @@ namespace DataPlant {
extern int TotNumHalfLoops; // number of half loops (2 * TotNumLoops)
extern bool PlantFirstSizeCompleted; //true if first-pass sizing is still going on and not finished
extern bool PlantFirstSizesOkayToFinalize; // true if first-pass plant sizing is finish and can save results for simulation
extern bool PlantReSizingNotComplete;
extern bool PlantReSizingCompleted;
extern bool PlantSizesOkayToReport; // true if plant sizing is really all done and results reported

extern bool AnyEMSPlantOpSchemesInModel;
Expand Down
90 changes: 47 additions & 43 deletions src/EnergyPlus/PlantChillers.cc
Original file line number Diff line number Diff line change
Expand Up @@ -257,9 +257,9 @@ namespace PlantChillers {
if ( InitLoopEquip ) {
TempEvapOutDesign = ElectricChiller( ChillNum ).TempDesEvapOut;
TempCondInDesign = ElectricChiller( ChillNum ).TempDesCondIn;
ElectricChiller( ChillNum ).IsThisSized = false;
// ElectricChiller( ChillNum ).IsThisSized = false;
InitElectricChiller( ChillNum, RunFlag, MyLoad );
ElectricChiller( ChillNum ).IsThisSized = true;
// ElectricChiller( ChillNum ).IsThisSized = true;
SizeElectricChiller( ChillNum );
if ( LoopNum == ElectricChiller( ChillNum ).Base.CWLoopNum ) { // chilled water loop
MinCap = ElectricChiller( ChillNum ).Base.NomCap * ElectricChiller( ChillNum ).MinPartLoadRat;
Expand Down Expand Up @@ -568,6 +568,9 @@ namespace PlantChillers {
}

ElectricChiller( ChillerNum ).Base.NomCap = rNumericArgs( 1 );
if ( ElectricChiller( ChillerNum ).Base.NomCap == AutoSize ) {
ElectricChiller( ChillerNum ).Base.NomCapWasAutoSized = true;
}
if ( rNumericArgs( 1 ) == 0.0 ) {
ShowSevereError( "Invalid " + cNumericFieldNames( 1 ) + '=' + RoundSigDigits( rNumericArgs( 1 ), 2 ) );
ShowContinueError( "Entered in " + cCurrentModuleObject + '=' + cAlphaArgs( 1 ) );
Expand Down Expand Up @@ -647,7 +650,15 @@ namespace PlantChillers {
ElectricChiller( ChillerNum ).TempRiseCoef = rNumericArgs( 7 );
ElectricChiller( ChillerNum ).TempDesEvapOut = rNumericArgs( 8 );
ElectricChiller( ChillerNum ).Base.EvapVolFlowRate = rNumericArgs( 9 );
if ( ElectricChiller( ChillerNum ).Base.EvapVolFlowRate == AutoSize ) {
ElectricChiller( ChillerNum ).Base.EvapVolFlowRateWasAutoSized = true;
}
ElectricChiller( ChillerNum ).Base.CondVolFlowRate = rNumericArgs( 10 );
if ( ElectricChiller( ChillerNum ).Base.CondVolFlowRate == AutoSize ) {
if ( ElectricChiller( ChillerNum ).Base.CondenserType == WaterCooled ) {
ElectricChiller( ChillerNum ).Base.CondVolFlowRateWasAutoSized = true;
}
}
ElectricChiller( ChillerNum ).CapRatCoef( 1 ) = rNumericArgs( 11 );
ElectricChiller( ChillerNum ).CapRatCoef( 2 ) = rNumericArgs( 12 );
ElectricChiller( ChillerNum ).CapRatCoef( 3 ) = rNumericArgs( 13 );
Expand Down Expand Up @@ -687,6 +698,10 @@ namespace PlantChillers {

// These are the Heat Recovery Inputs
ElectricChiller( ChillerNum ).DesignHeatRecVolFlowRate = rNumericArgs( 21 );
if ( ElectricChiller( ChillerNum ).DesignHeatRecVolFlowRate == AutoSize ) {
ElectricChiller( ChillerNum ).DesignHeatRecVolFlowRateWasAutoSized = true;
}

if ( ( ElectricChiller( ChillerNum ).DesignHeatRecVolFlowRate > 0.0 ) || ( ElectricChiller( ChillerNum ).DesignHeatRecVolFlowRate == AutoSize ) ) {
ElectricChiller( ChillerNum ).HeatRecActive = true;
ElectricChiller( ChillerNum ).HeatRecInletNodeNum = GetOnlySingleNode( cAlphaArgs( 8 ), ErrorsFound, cCurrentModuleObject, cAlphaArgs( 1 ), NodeType_Water, NodeConnectionType_Inlet, 3, ObjectIsNotParent );
Expand Down Expand Up @@ -2096,7 +2111,7 @@ namespace PlantChillers {
}

if ( MyEnvrnFlag( ChillNum ) && BeginEnvrnFlag && ( PlantFirstSizesOkayToFinalize ) ) {
if ( ! PlantFirstSizeCompleted ) SizeElectricChiller( ChillNum );
// if ( ! PlantFirstSizeCompleted ) SizeElectricChiller( ChillNum );
rho = GetDensityGlycol( PlantLoop( ElectricChiller( ChillNum ).Base.CWLoopNum ).FluidName, InitConvTemp, PlantLoop( ElectricChiller( ChillNum ).Base.CWLoopNum ).FluidIndex, RoutineName );

ElectricChiller( ChillNum ).Base.EvapMassFlowRateMax = rho * ElectricChiller( ChillNum ).Base.EvapVolFlowRate;
Expand Down Expand Up @@ -2952,6 +2967,7 @@ namespace PlantChillers {
using namespace DataSizing;
using DataPlant::PlantLoop;
using DataPlant::PlantFirstSizesOkayToFinalize;
using DataPlant::PlantSizesOkayToReport;
using PlantUtilities::RegisterPlantCompDesignFlow;
using ReportSizingManager::ReportSizingOutput;
using namespace OutputReportPredefined;
Expand Down Expand Up @@ -3010,28 +3026,27 @@ namespace PlantChillers {

PltSizNum = PlantLoop( ElectricChiller( ChillNum ).Base.CWLoopNum ).PlantSizNum;

if ( ElectricChiller( ChillNum ).Base.NomCap == AutoSize ) {
IsAutoSize = true;
}


if ( PltSizNum > 0 ) {
if ( PlantSizData( PltSizNum ).DesVolFlowRate >= SmallWaterVolFlow ) {
rho = GetDensityGlycol( PlantLoop( ElectricChiller( ChillNum ).Base.CWLoopNum ).FluidName, InitConvTemp, PlantLoop( ElectricChiller( ChillNum ).Base.CWLoopNum ).FluidIndex, RoutineName );
Cp = GetSpecificHeatGlycol( PlantLoop( ElectricChiller( ChillNum ).Base.CWLoopNum ).FluidName, InitConvTemp, PlantLoop( ElectricChiller( ChillNum ).Base.CWLoopNum ).FluidIndex, RoutineName );
tmpNomCap = Cp * rho * PlantSizData( PltSizNum ).DeltaT * PlantSizData( PltSizNum ).DesVolFlowRate * ElectricChiller( ChillNum ).Base.SizFac;
if ( ! IsAutoSize ) tmpNomCap = ElectricChiller( ChillNum ).Base.NomCap;
if ( ! ElectricChiller( ChillNum ).Base.NomCapWasAutoSized ) tmpNomCap = ElectricChiller( ChillNum ).Base.NomCap;
} else {
if ( IsAutoSize ) tmpNomCap = 0.0;
if ( ElectricChiller( ChillNum ).Base.NomCapWasAutoSized ) tmpNomCap = 0.0;
}
if ( PlantFirstSizesOkayToFinalize ) {
if ( IsAutoSize ) {
if ( ElectricChiller( ChillNum ).Base.NomCapWasAutoSized ) {
ElectricChiller( ChillNum ).Base.NomCap = tmpNomCap;
if ( ! ElectricChiller( ChillNum ).Base.IsThisSized ) {
if ( PlantSizesOkayToReport ) {
ReportSizingOutput( "Chiller:Electric", ElectricChiller( ChillNum ).Base.Name, "Design Size Nominal Capacity [W]", tmpNomCap );
}
} else {
if ( ElectricChiller( ChillNum ).Base.NomCap > 0.0 && tmpNomCap > 0.0 ) {
NomCapUser = ElectricChiller( ChillNum ).Base.NomCap;
if ( ! ElectricChiller( ChillNum ).Base.IsThisSized ) {
if ( PlantSizesOkayToReport ) {
ReportSizingOutput( "Chiller:Electric", ElectricChiller( ChillNum ).Base.Name, "Design Size Nominal Capacity [W]", tmpNomCap, "User-Specified Nominal Capacity [W]", NomCapUser );
if ( DisplayExtraWarnings ) {
if ( ( std::abs( tmpNomCap - NomCapUser ) / NomCapUser ) > AutoVsHardSizingThreshold ) {
Expand All @@ -3048,40 +3063,36 @@ namespace PlantChillers {
}
}
} else {
if ( IsAutoSize ) {
if ( ElectricChiller( ChillNum ).Base.NomCapWasAutoSized && PlantSizesOkayToReport ) {
ShowSevereError( "Autosizing of Electric Chiller nominal capacity requires a loop Sizing:Plant object" );
ShowContinueError( "Occurs in Electric Chiller object=" + ElectricChiller( ChillNum ).Base.Name );
ErrorsFound = true;
} else {
if ( ! ElectricChiller( ChillNum ).Base.IsThisSized ) {
if ( PlantSizesOkayToReport ) {
if ( ElectricChiller( ChillNum ).Base.NomCap > 0.0 ) {
ReportSizingOutput( "Chiller:Electric", ElectricChiller( ChillNum ).Base.Name, "User-Specified Nominal Capacity [W]", ElectricChiller( ChillNum ).Base.NomCap );
}
}
}
}

IsAutoSize = false;
if ( ElectricChiller( ChillNum ).Base.EvapVolFlowRate == AutoSize ) {
IsAutoSize = true;
}
if ( PltSizNum > 0 ) {
if ( PlantSizData( PltSizNum ).DesVolFlowRate >= SmallWaterVolFlow ) {
tmpEvapVolFlowRate = PlantSizData( PltSizNum ).DesVolFlowRate * ElectricChiller( ChillNum ).Base.SizFac;
if ( ! IsAutoSize ) tmpEvapVolFlowRate = ElectricChiller( ChillNum ).Base.EvapVolFlowRate;
if ( ! ElectricChiller( ChillNum ).Base.EvapVolFlowRateWasAutoSized ) tmpEvapVolFlowRate = ElectricChiller( ChillNum ).Base.EvapVolFlowRate;
} else {
if ( IsAutoSize ) tmpEvapVolFlowRate = 0.0;
if ( ElectricChiller( ChillNum ).Base.EvapVolFlowRateWasAutoSized ) tmpEvapVolFlowRate = 0.0;
}
if ( PlantFirstSizesOkayToFinalize ) {
if ( IsAutoSize ) {
if ( ElectricChiller( ChillNum ).Base.EvapVolFlowRateWasAutoSized ) {
ElectricChiller( ChillNum ).Base.EvapVolFlowRate = tmpEvapVolFlowRate;
if ( ! ElectricChiller( ChillNum ).Base.IsThisSized ) {
if ( PlantSizesOkayToReport) {
ReportSizingOutput( "Chiller:Electric", ElectricChiller( ChillNum ).Base.Name, "Design Size Design Chilled Water Flow Rate [m3/s]", tmpEvapVolFlowRate );
}
} else {
if ( ElectricChiller( ChillNum ).Base.EvapVolFlowRate > 0.0 && tmpEvapVolFlowRate > 0.0 ) {
EvapVolFlowRateUser = ElectricChiller( ChillNum ).Base.EvapVolFlowRate;
if ( ! ElectricChiller( ChillNum ).Base.IsThisSized ) {
if ( PlantSizesOkayToReport ) {
ReportSizingOutput( "Chiller:Electric", ElectricChiller( ChillNum ).Base.Name, "Design Size Design Chilled Water Flow Rate [m3/s]", tmpEvapVolFlowRate, "User-Specified Design Chilled Water Flow Rate [m3/s]", EvapVolFlowRateUser );
if ( DisplayExtraWarnings ) {
if ( ( std::abs( tmpEvapVolFlowRate - EvapVolFlowRateUser ) / EvapVolFlowRateUser ) > AutoVsHardSizingThreshold ) {
Expand All @@ -3098,12 +3109,12 @@ namespace PlantChillers {
}
}
} else {
if ( IsAutoSize ) {
if ( ElectricChiller( ChillNum ).Base.EvapVolFlowRateWasAutoSized && PlantSizesOkayToReport) {
ShowSevereError( "Autosizing of Electric Chiller evap flow rate requires a loop Sizing:Plant object" );
ShowContinueError( "Occurs in Electric Chiller object=" + ElectricChiller( ChillNum ).Base.Name );
ErrorsFound = true;
} else {
if ( ! ElectricChiller( ChillNum ).Base.IsThisSized ) {
if ( PlantSizesOkayToReport ) {
if ( ElectricChiller( ChillNum ).Base.EvapVolFlowRate > 0.0 ) {
ReportSizingOutput( "Chiller:Electric", ElectricChiller( ChillNum ).Base.Name, "User-Specified Design Chilled Water Flow Rate [m3/s]", ElectricChiller( ChillNum ).Base.EvapVolFlowRate );
}
Expand All @@ -3113,30 +3124,26 @@ namespace PlantChillers {

RegisterPlantCompDesignFlow( ElectricChiller( ChillNum ).Base.EvapInletNodeNum, tmpEvapVolFlowRate );

IsAutoSize = false;
if ( ElectricChiller( ChillNum ).Base.CondVolFlowRate == AutoSize ) {
IsAutoSize = true;
}
if ( PltSizCondNum > 0 && PltSizNum > 0 ) {
if ( PlantSizData( PltSizNum ).DesVolFlowRate >= SmallWaterVolFlow && tmpNomCap > 0.0 ) {
rho = GetDensityGlycol( PlantLoop( ElectricChiller( ChillNum ).Base.CDLoopNum ).FluidName, ElectricChiller( ChillNum ).TempDesCondIn, PlantLoop( ElectricChiller( ChillNum ).Base.CDLoopNum ).FluidIndex, RoutineName );

Cp = GetSpecificHeatGlycol( PlantLoop( ElectricChiller( ChillNum ).Base.CDLoopNum ).FluidName, ElectricChiller( ChillNum ).TempDesCondIn, PlantLoop( ElectricChiller( ChillNum ).Base.CDLoopNum ).FluidIndex, RoutineName );
tmpCondVolFlowRate = tmpNomCap * ( 1.0 + 1.0 / ElectricChiller( ChillNum ).Base.COP ) / ( PlantSizData( PltSizCondNum ).DeltaT * Cp * rho );
if ( ! IsAutoSize ) tmpCondVolFlowRate = ElectricChiller( ChillNum ).Base.CondVolFlowRate;
if ( ! ElectricChiller( ChillNum ).Base.CondVolFlowRateWasAutoSized ) tmpCondVolFlowRate = ElectricChiller( ChillNum ).Base.CondVolFlowRate;
} else {
if ( IsAutoSize ) tmpCondVolFlowRate = 0.0;
if ( ElectricChiller( ChillNum ).Base.CondVolFlowRateWasAutoSized ) tmpCondVolFlowRate = 0.0;
}
if ( PlantFirstSizesOkayToFinalize ) {
if ( IsAutoSize ) {
if ( ElectricChiller( ChillNum ).Base.CondVolFlowRateWasAutoSized ) {
ElectricChiller( ChillNum ).Base.CondVolFlowRate = tmpCondVolFlowRate;
if ( ! ElectricChiller( ChillNum ).Base.IsThisSized ) {
if (PlantSizesOkayToReport) {
ReportSizingOutput( "Chiller:Electric", ElectricChiller( ChillNum ).Base.Name, "Design Size Design Condenser Water Flow Rate [m3/s]", tmpCondVolFlowRate );
}
} else {
if ( ElectricChiller( ChillNum ).Base.CondVolFlowRate > 0.0 && tmpCondVolFlowRate > 0.0 ) {
CondVolFlowRateUser = ElectricChiller( ChillNum ).Base.CondVolFlowRate;
if ( ! ElectricChiller( ChillNum ).Base.IsThisSized ) {
if ( PlantSizesOkayToReport ) {
ReportSizingOutput( "Chiller:Electric", ElectricChiller( ChillNum ).Base.Name, "Design Size Design Condenser Water Flow Rate [m3/s]", tmpCondVolFlowRate, "User-Specified Design Condenser Water Flow Rate [m3/s]", CondVolFlowRateUser );
if ( DisplayExtraWarnings ) {
if ( ( std::abs( tmpCondVolFlowRate - CondVolFlowRateUser ) / CondVolFlowRateUser ) > AutoVsHardSizingThreshold ) {
Expand All @@ -3153,13 +3160,13 @@ namespace PlantChillers {
}
}
} else {
if ( IsAutoSize ) {
if ( ElectricChiller( ChillNum ).Base.CondVolFlowRateWasAutoSized && PlantSizesOkayToReport ) {
ShowSevereError( "Autosizing of Electric Chiller condenser flow rate requires a condenser" );
ShowContinueError( "loop Sizing:Plant object" );
ShowContinueError( "Occurs in Electric Chiller object=" + ElectricChiller( ChillNum ).Base.Name );
ErrorsFound = true;
} else {
if ( ! ElectricChiller( ChillNum ).Base.IsThisSized ) {
if ( PlantSizesOkayToReport ) {
if ( ElectricChiller( ChillNum ).Base.CondVolFlowRate > 0.0 ) {
ReportSizingOutput( "Chiller:Electric", ElectricChiller( ChillNum ).Base.Name, "User-Specified Design Condenser Water Flow Rate [m3/s]", ElectricChiller( ChillNum ).Base.CondVolFlowRate );
}
Expand All @@ -3177,22 +3184,19 @@ namespace PlantChillers {

if ( ElectricChiller( ChillNum ).HeatRecActive ) {
tmpHeatRecVolFlowRate = ElectricChiller( ChillNum ).DesignHeatRecVolFlowRate;
IsAutoSize = false;
if ( ElectricChiller( ChillNum ).DesignHeatRecVolFlowRate == AutoSize ) {
IsAutoSize = true;
}

tmpHeatRecVolFlowRate = ElectricChiller( ChillNum ).Base.CondVolFlowRate * ElectricChiller( ChillNum ).HeatRecCapacityFraction;
if ( ! IsAutoSize ) tmpHeatRecVolFlowRate = ElectricChiller( ChillNum ).DesignHeatRecVolFlowRate;
if ( ! ElectricChiller( ChillNum ).DesignHeatRecVolFlowRateWasAutoSized ) tmpHeatRecVolFlowRate = ElectricChiller( ChillNum ).DesignHeatRecVolFlowRate;
if ( PlantFirstSizesOkayToFinalize ) {
if ( IsAutoSize ) {
if ( ElectricChiller( ChillNum ).DesignHeatRecVolFlowRateWasAutoSized ) {
ElectricChiller( ChillNum ).DesignHeatRecVolFlowRate = tmpHeatRecVolFlowRate;
if ( ! ElectricChiller( ChillNum ).Base.IsThisSized ) {
if ( PlantSizesOkayToReport ) {
ReportSizingOutput( "Chiller:Electric", ElectricChiller( ChillNum ).Base.Name, "Design Size Design Heat Recovery Fluid Flow Rate [m3/s]", tmpHeatRecVolFlowRate );
}
} else {
if ( ElectricChiller( ChillNum ).DesignHeatRecVolFlowRate > 0.0 && tmpHeatRecVolFlowRate > 0.0 ) {
DesignHeatRecVolFlowRateUser = ElectricChiller( ChillNum ).DesignHeatRecVolFlowRate;
if ( ! ElectricChiller( ChillNum ).Base.IsThisSized ) {
if ( PlantSizesOkayToReport ) {
ReportSizingOutput( "Chiller:Electric", ElectricChiller( ChillNum ).Base.Name, "Design Size Design Heat Recovery Fluid Flow Rate [m3/s]", tmpHeatRecVolFlowRate, "User-Specified Design Heat Recovery Fluid Flow Rate [m3/s]", DesignHeatRecVolFlowRateUser );
if ( DisplayExtraWarnings ) {
if ( ( std::abs( tmpHeatRecVolFlowRate - DesignHeatRecVolFlowRateUser ) / DesignHeatRecVolFlowRateUser ) > AutoVsHardSizingThreshold ) {
Expand Down
Loading

6 comments on commit 80efac7

@nrel-bot
Copy link

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

HVACSizingSim_CoincidentPlant (EnergyArchmage) - x86_64-Linux-Ubuntu-14.04-gcc-4.8: Build Failed

Build Badge Test Badge

@nrel-bot
Copy link

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

HVACSizingSim_CoincidentPlant (EnergyArchmage) - x86_64-Linux-Ubuntu-14.04-cppcheck-1.61: OK (0 of 0 tests passed)

Build Badge

@nrel-bot
Copy link

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

HVACSizingSim_CoincidentPlant (EnergyArchmage) - x86_64-Linux-Ubuntu-14.04-gcc-4.8-UnitTestsCoverage-Debug: Build Failed

Build Badge Test Badge Coverage Badge

@nrel-bot
Copy link

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

HVACSizingSim_CoincidentPlant (EnergyArchmage) - i386-Windows-7-VisualStudio-12: OK (1569 of 1590 tests passed)

Build Badge Test Badge

@nrel-bot
Copy link

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

HVACSizingSim_CoincidentPlant (EnergyArchmage) - x86_64-Linux-Ubuntu-14.04-gcc-4.8-IntegrationCoverage-Debug: Build Failed

Build Badge Test Badge Coverage Badge

@nrel-bot
Copy link

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

HVACSizingSim_CoincidentPlant (EnergyArchmage) - Win64-Windows-7-VisualStudio-12: OK (1569 of 1590 tests passed)

Build Badge Test Badge

Please sign in to comment.