Notifications
You must be signed in to change notification settings - Fork 1.7k
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
[Wrong device]: MOES Smart Plug - UK (TS011F - _TZ3000_yujkchbz) #17593
Comments
How is it currently detected, |
Detected as TuYa TS011F_plug_1 |
Thanks, will be fixed with the next release. |
Thanks, I updated to 1.30.4-dev commit: [dddd2bc] and all looks good, apart from the photo. it is linked to this, but that is a photo of a Loratap switch? Also, if I click on the model link in the device page, it goes to a blank page. Unless it is not ready in Dev and only will be ready in the master release, then sorry for jumping the gun. Thanks |
Picture will be updated after the next release. |
Link
https://www.aliexpress.com/item/1005004694257109.html?spm=a2g0o.order_list.order_list_main.46.4e621802uvgY2J
Model
MOES Smart Plug
Description
Smart Plug (with power monitoring)
Vendor
MOES
Picture (link)
https://ae01.alicdn.com/kf/S0d3d61222fdb4736be378f27fcac82d8f/MOES-ZigBee-Tuya-Socket-Power-Plug-16A-Smart-APP-Wireless-Socket-Outlet-Functional-Energy-Monitor-Timer.jpg_640x640.jpg
Database entry
{"id":33,"type":"Router","ieeeAddr":"0xa4c13807a873d80e","nwkAddr":63716,"manufId":4417,"manufName":"_TZ3000_yujkchbz","powerSource":"Mains (single phase)","modelId":"TS011F","epList":[1,242],"endpoints":{"1":{"profId":260,"epId":1,"devId":266,"inClusterList":[3,4,5,6,1794,2820,57345,57344,0],"outClusterList":[25,10],"clusters":{"genBasic":{"attributes":{"65503":"\u0000\u0000\u0000\u0000\u0012\u0000\u0000\u0000\u0000\u0012\u0000\u0000\u0000\u0000\u0012","65506":53,"65508":0,"65534":0,"modelId":"TS011F","manufacturerName":"_TZ3000_yujkchbz","powerSource":1,"zclVersion":3,"appVersion":74,"stackVersion":0,"hwVersion":1,"dateCode":""}},"genOnOff":{"attributes":{"32768":0,"onOff":1,"onTime":0,"offWaitTime":0,"tuyaBacklightMode":1,"moesStartUpOnOff":1,"tuyaBacklightSwitch":1}},"manuSpecificTuya_3":{"attributes":{"53248":0,"53249":0,"53250":0,"53251":0,"53252":0,"53253":0,"powerOnBehavior":1,"switchType":0}},"haElectricalMeasurement":{"attributes":{"rmsVoltage":235,"acCurrentDivisor":1000,"acCurrentMultiplier":1,"rmsCurrent":86,"activePower":10}},"seMetering":{"attributes":{"divisor":100,"multiplier":1,"currentSummDelivered":[0,107]}}},"binds":[{"cluster":6,"type":"endpoint","deviceIeeeAddress":"0x94deb8fffeecb1a4","endpointID":1},{"cluster":2820,"type":"endpoint","deviceIeeeAddress":"0x94deb8fffeecb1a4","endpointID":1},{"cluster":1794,"type":"endpoint","deviceIeeeAddress":"0x94deb8fffeecb1a4","endpointID":1}],"configuredReportings":[{"cluster":2820,"attrId":1285,"minRepIntval":5,"maxRepIntval":3600,"repChange":5},{"cluster":2820,"attrId":1288,"minRepIntval":5,"maxRepIntval":3600,"repChange":50},{"cluster":2820,"attrId":1291,"minRepIntval":5,"maxRepIntval":3600,"repChange":10},{"cluster":1794,"attrId":0,"minRepIntval":5,"maxRepIntval":3600,"repChange":[1,1]}],"meta":{}},"242":{"profId":41440,"epId":242,"devId":97,"inClusterList":[],"outClusterList":[33],"clusters":{},"binds":[],"configuredReportings":[],"meta":{}}},"appVersion":74,"stackVersion":0,"hwVersion":1,"dateCode":"","zclVersion":3,"interviewCompleted":true,"meta":{"configured":-892627439},"lastSeen":1683512813803,"defaultSendRequestWhen":"immediate"}
Notes
Plug does not have a model NUMBER on it, just "MOES Smart Plug"
The text was updated successfully, but these errors were encountered: