This allows for boards that don't run their ADC with 3.3V to output accurate MCU temperature readings.
This was originally posted in Klipper3d/klipper#5713 but was rejected by mainline.
The code was written by iKirin of Annex Engineering. With his permission, I've cleaned it up a bit, added a few missing cases and formatted it with Black.
The use case for this is especially rp2040 boards with accurate ADC references. Because of how the Pico board is set up, getting a stable reference is only possible by pulling the reference down to 3.0V. Without this patch, a 3.3V reference is assumed.