viewer presets for dds devices #13074
Conversation
I think that back than we discussed it and decided not to check read only. Leave it for the server to fail if trying to update read only. |
Not sure I understand what is special in the preset value. Changing preset triggers a change in a group of "advanced mode" options, but it does not affect regular options like exposure and such. |
The Visual Preset sets parameters that may not even have equivalents available to the user: internal settings. The idea here is that the preset determines the "baseline" on top of which the rest of the settings are then applied. |
Enabled Viewer presets in DDS devices.
The Viewer detects that a device has presets based on implementation of
serializable_interface
.Added a unit-test making sure that DDS devices are serializable, and have their Visual Preset set first when loading JSON.
The values for all serialized sensors are kept in
<sensor-name>/<option-name>
keys when serializing.On loading, the
Visual Preset
option is special: it is the baseline for all other options, so it is changed first. Then all the rest of the options are loaded.Enhanced test.remote so capture of remote stdout is possible.
Read-only options were not tested before. Added a test for those as well, but noticed that they are actually settable (i.e., it was up to the server to check read-only). I don't know what's right at this point, but I think it's safe for LibRS to fail and throw if a read-only option is modified. The code for the regular non-DDS options also seems to not check.
Tracked on [RSDEV-986]