Requirements

  • Home Assistant version that supports custom integrations.
  • Python package: imeon_inverter_api

Installation

To install the Imeon Inverter integration, follow these steps:

  1. Download the Integration:

    • Clone or download this repository to your Home Assistant custom_components directory.
  2. Install Requirements:

    • There should be none, as Home Assistant will ensure the following packages are downloaded:
      imeon_inverter_api
      
  3. Restart Home Assistant:

    • After downloading the integration and installing the requirements, restart your Home Assistant instance to load the new integration.

Configuration

The Imeon Inverter integration supports configuration via the Home Assistant UI. To set it up:

  1. Access Integrations:

    • Go to the Home Assistant UI, navigate to Configuration > Integrations.
  2. Add Integration:

    • Click the "+" button to add a new integration and search for "Imeon Inverter".
  3. Follow Setup Wizard:

    • Follow the on-screen instructions to complete the integration setup.

Features

  • Local Polling: The integration communicates with the Imeon Inverter using local polling, ensuring data privacy and reducing latency.
  • Config Flow: Supports configuration through the Home Assistant UI for ease of use.
  • Hub Integration: Acts as a hub for managing multiple devices and sensors associated with the Imeon Inverter.
  • Services: Allows to modify certain settings for the inverter either manually or with automations

Services

These can be found Developer tools > Actions. For a given service name you will find it under the name <inverter-name>_<action-name>.

Inverter Mode : *_inverter_mode

  • Friendly Name: Inverter Mode
  • Description: Change the mode of the inverter.
  • Fields:
    • mode (string):
      • Allowed values: 'smg', 'bup', 'ong', 'ofg'
      • Example: 'smg'

Maximum Power Point Tracking Range : *_mppt

  • Friendly Name: Maximum Power Point Tracking Range
  • Description: Change the working range of the MPPT.
  • Fields:
    • low (integer):
      • Minimum value: 350
      • Example: 350
    • high (integer):
      • Maximum value: 700
      • Example: 700

Grid Feed-in (Injection) : *_feed_in

  • Friendly Name: Grid Feed-in (Injection)
  • Description: Change whether or not the inverter injects power into the grid.
  • Fields:
    • active (boolean):
      • Example: True

Injection Power Limit : *_injection_power

  • Friendly Name: Injection Power Limit
  • Description: Change the power limit when injecting into the grid.
  • Fields:
    • limit (integer):
      • Range: 0 - 8000
      • Example: 3000

LCD Screen Sleep Time : *_lcd_time

  • Friendly Name: LCD Screen Sleep Time
  • Description: Change the time it takes for the LCD screen to go to sleep.
  • Fields:
    • time (integer):
      • Allowed values: 0, 1, 2, 10, 20
      • Example: 0

Battery Night Discharge : *_night_discharge

  • Friendly Name: Battery Night Discharge
  • Description: Change whether or not the battery should discharge at night.
  • Fields:
    • active (boolean):
      • Allowed values: True, False
      • Example: False

Battery Charge From Grid : *_grid_charge

  • Friendly Name: Battery Charge From Grid
  • Description: Change whether or not the battery should charge from the grid.
  • Fields:
    • active (boolean):
      • Allowed values: True, False
      • Example: False

Relay State : *_relay

  • Friendly Name: Relay State
  • Description: Change the state of the relay.
  • Fields:
    • active (boolean):
      • Allowed values: True, False
      • Example: False

AC Output State : *_ac_output

  • Friendly Name: AC Output State
  • Description: Change whether or not the AC output should be active.
  • Fields:
    • active (boolean):
      • Allowed values: True, False
      • Example: True

Smartload : *_smartload

  • Friendly Name: Smartload
  • Description: Returns the information of Smartload, which allocates energy loads over time.
  • Fields:
    • None needed, this is read only!

Service response

All service responses are composed of a JSON Serializable Object, built as such:

{"result": "failed"}

{"result": "success"}

Smartload is an exception and sends back information within the JSON on success.

Troubleshooting

If you encounter any issues, please ensure that all requirements are installed and that Home Assistant is properly configured to allow custom integrations. For further assistance, consider reaching out to the Home Assistant community or checking the logs for more detailed error messages.

Contribution

sensor.inverter_86_monitoring_building_consumption_minute Contributions to improve the Imeon Inverter integration are welcome. Please fork the repository and submit a pull request with your changes.

License

This project is licensed under the Apache 2.0 License. See the LICENSE file for more details.

About

Custom Home Assistant integration for Imeon Energy inverters.

Topics

Resources

License

Stars

Watchers

Forks

Releases

No releases published

Packages

No packages published

Languages