hi
M-2000C/EMER_HYD_PUMP_SW need 3 state almost 2 actually
it's off/neutral/on and not on/off
ON isn't static state but return to neutral after press
OFF/NEUTRAL is static
actualy press ON --> stay at ON status
thx
The text was updated successfully, but these errors were encountered:
it works ! pos on/off is now working :)
but not really perfect coz there are 3 pos
off : stay in this state =0
ON : stay in this state = 1 front push : do not stay in state but goback ON pos after push = 2
perhasps it's in dcsfp the answer ?