Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

M-2000C/EMER_HYD_PUMP_SW wrong state value, not on/off but on/neutral/off #88

Closed
shan-aya opened this issue Feb 12, 2022 · 1 comment
Closed

Comments

@shan-aya
Copy link

hi
M-2000C/EMER_HYD_PUMP_SW need 3 state almost 2 actually
it's off/neutral/on and not on/off
ON isn't static state but return to neutral after press
OFF/NEUTRAL is static

actualy press ON --> stay at ON status

thx

WarLord211 added a commit that referenced this issue Feb 12, 2022
@WarLord211 WarLord211 added bug A bug affecting dcs-bios Need testing-fix uploaded labels Feb 12, 2022
@shan-aya
Copy link
Author

shan-aya commented Feb 12, 2022

it works ! pos on/off is now working :)
but not really perfect coz there are 3 pos
off : stay in this state =0
ON : stay in this state = 1
front push : do not stay in state but goback ON pos after push = 2
perhasps it's in dcsfp the answer ?
thx

@WarLord211 WarLord211 added Fixed and removed bug A bug affecting dcs-bios Need testing-fix uploaded labels Feb 13, 2022
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment