Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

MINTEMP, Slightly lower temperature before triggering sensor fault. #233

Open
wants to merge 1 commit into
base: master
Choose a base branch
from

Conversation

platenboring
Copy link

In Scotland it gets cold.
At startup in Winter, the temps were reading 3-4 degrees, so triggering a sensor missing fault. Until warmed up with a hairdryer !
I'm not sure if zero, or negative value is acceptable so I've changed MINTEMP from 5 to 1.
If zero is OK then I'd go for that.

In Scotland it gets cold.
At startup in Winter, the temps were reading 3-4 degrees, so triggering a sensor missing fault.  Until warmed up with a hairdryer !
I'm not sure if zero, or negative value is acceptable so I've changed MINTEMP from 5 to 1.
If zero is OK then I'd go for that.
@fjohannes
Copy link

maybe you should check for yourself, if a disconnected thermistor still gets detected reliably with this setting.

@platenboring
Copy link
Author

platenboring commented Mar 6, 2021 via email