# This is the template file pyPlc.ini.template. # Copy this file in the same folder like the pyPlc.py, and rename it to pyPlc.ini [general] # mode can be either PevMode to use as car, or EvseMode to use as charger mode = EvseMode # Simulation without modem # For development purposes, make it possible to run two instances (pev and evse) on one machine, without # a modem connected. This feature is not tested since a long time, most likely does not work as intended. # todo: replace isSimulationMode by this setting is_simulation_without_modems = false # The Ethernet interface. Usually eth0 on Raspberry. # This setting is considered only on linux. eth_interface = eth1 # The Ethernet interface name on Windows. Something like # \Device\NPF_{E4B8176C-8516-4D48-88BC-85225ABCF259} eth_windows_interface_name = \Device\NPF_{E4B8176C-8516-4D48-88BC-85225ABCF259} # If a display is connected via serial line, e.g. an WIFI-KIT-32 running the software from https://github.com/uhi22/SerialToOLED display_via_serial = yes # LightBulbDemo turns on the relay with a short delay in the charging loop, to stabilize the voltage # before the resistive load is connected. light_bulb_demo = no # SOC simulation. # In PevMode, simulate a rising SOC while charging. soc_simulation = yes # Device selection for the digital outputs, for CP state and power relays # Possible options: # dieter: Serial controlled device, which controls the digital outputs. E.g. arduino from https://github.com/uhi22/dieter # beaglebone: GPIO pins of the beagleBone, as used in https://github.com/jsphuebner/pyPLC/tree/beaglebone # celeron55device: Serial controlled device as used in https://openinverter.org/forum/viewtopic.php?p=56192#p56192 digital_output_device = dieter #digital_output_device = beaglebone #digital_output_device = celeron55device # Device to read the physically measured inlet voltage in PevMode # Possible options: # dieter: The high-voltage dieter from https://github.com/uhi22/dieter, which is connected on serial port. # none: if no measurement is intended. # celeron55device: as used in https://openinverter.org/forum/viewtopic.php?p=56192#p56192 #analog_input_device = dieter analog_input_device = none #analog_input_device = celeron55device # Criteria for ending the PreCharge phase in PevMode # Possible options: # yes: use the EVSEPresentVoltage which is reported by the charger, to decide the end of the precharge # no: use the physically measured inlet voltage to decide the end of the precharge use_evsepresentvoltage_for_precharge_end = yes # Use the physically measured inlet voltage to show on display during the charge loop. # If false, we are showing the EVSEPresentVoltage which is reported by the charger. use_physical_inlet_voltage_during_chargeloop = no # Voltage threshold for the end-of-precharge decision # This is the maximum difference voltage between the charger voltage and the accu voltage. If the actual voltage # difference is lower than this threshold, we will close the power relay, to connect the accu to the charger. # Unit: volt u_delta_max_for_end_of_precharge = 10 # Added by celeron55 # The serial port and baud rate used for communication. Used # for serial devices like Dieter, OLED-Display and # celeron55's measuring and switching device # Examples: # /dev/ttyS1 # auto serial_port = auto serial_baud = 19200 # The target voltage used in the CurrentDemandRequest. # This is a value for first try-outs. Better would # be if the BMS would provide the value. # 11 * 6 * 4.1V = 66 * 4.1V = 270V charge_target_voltage = 270 # By using an external manager script, this is useful for splitting charging # into separately logged sessions and avoiding logging when not connected to a # charger exit_on_session_end = False # Run test cases. # Explanation in doc/testing_and_simulation.md # Possible values: # No: No testcases are executed. Normal function as Evse or Pev. # Yes: Testcases are executed. The EvseMode will produce various errors for fault injection tests. testsuite_enable = No # Logging to UDP Syslog messages # If this is activated, the pyPlc will send all logging messages also to the network interface, # in form of UDP Syslog messages. For details see in udplog.py. udp_syslog_enable = Yes # Set backend for obtaining charging parameters, we start with CHAdeMO CAN for now # Need to make a simulator device and maybe a celeron device? charge_parameter_backend = chademo # REST callback for SoC states. Comment out to disable. Do not leave a trailing slash soc_callback_enabled = True soc_callback_endpoint = http://192.168.1.119 # Fallback value to use if the vehicle does not support the EVEnergyCapacity.Value soc_fallback_energy_capacity = 2700