Notifications
You must be signed in to change notification settings - Fork 0
/
k197-spi.h
127 lines (104 loc) · 5.61 KB
/
k197-spi.h
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
#pragma once
#define MODES_BYTE 8
#define UNITS_BYTE 15
#define UNIT2_BYTE 16
#define PACKET 18 // our SPI packet is 18 bytes
#define FIRST_DIGIT 9
#define LAST_DIGIT 14
/* Keithley 197(a):
*
* The Keithley 197(a) multimeter sends status information on bytes 8, 15, and 16. This
* assumes that we are starting when SCK goes _SCK_ (low), which is usually 0x20.
*
* This information can be derived (in part?) from the schematic page of the LCD screen itself,
* under the portion CONTACT DESCRIPTION.
*
* The Keithley 175 may use different settings, so your mileage may vary.
*
* The MODES byte contains information about the overall operation of the meter. These
* bits can be set in multiple measuring modes (REL works in all modes, including dB).
*
* The following bits provide context to measurements:
*
* * STO - The measurement is stored in addition to being displayed. Depending on the n=
* setting, it may slow down measurement (to as slow as 1 per day). Not necessary with recording
* interface. Generates HI/LO from among the read values since STO started.
*
* * dB - Returns a decibel value, referenced to 600 Ohm @ 1 mV = 1 dBm.
*
* The following bits imply a different mode of operation than the standard one, measurement:
*
* * RCL - There are up to 100 stored measurements, plus two extra (HI and LO), which can be played back
* as though they are live measurements.
*
* * CAL - When in the calibration mode, certain buttons are used to change the value displayed on the screen.
* These values are emitted *very* fast, much faster than normal measurements.
* FIXME: This currently does not work properly. Measurement on screen does not change. Must be in CAL store mode?
*
* * RMT - Indicates the device is in GPIB mode. FIXME: Currently untested.
*
* * AUTO - The device is in AUTORANGING mode. Implies that the device may change units at any time.
*
*
* Note also that multiple bits may be set as logic would demand, for instance:
*
* * If you are measuring a value in milliohms, then _mO() and __O() may be set.
*/
/*
* Other information gleaned from reading the LCD control display, looking at logic analyser data:
*
* In the COMMAND spots, a typical string (in fact, the only string one ever sees in normal operation) is:
*
* 0x20 0x30 0x4A 0x14 0x00 0x18 0x11 0x20
*
* In command language, these may be:
*
* 0x20 - CLEAR DATA MEMORY
* 0x30 - UNSYNCHRONIZED TRANSFER (display data is re-written upon raising of C/S pin)
* 0x4A - MODE SET: (1/3rd bias mode, 3-time-sharing-drive, 2^9 scale ratio)
* 0x14 - WITHOUT SEGMENT DECODER (data passed in directly to memory, without segment decoder)
* 0x00 - CLEAR BLINKING DATA MEMORY
* 0x18 - BLINKING OFF
* 0x11 - DISPLAY ON (after this upcoming data packet, display the data)
* 0x20 - CLEAR DATA MEMORY (clear data memory again, for whatever reason)
*
*
* The startup sequence looks like:
*
* 0x10 0x20 0x30 0x4A 0x14 0x00 0x18 0x11
* 0x20 0x30 0x4A 0x14 0x00 0x18 0x11 0x20 0x00 0xEB 0xEB 0xEB 0xEB 0xEB 0x00 0x00
*
* This is just a normal COMMAND sequence repeated twice (as above), but with the prefix:
*
* 0x10 - DISPLAY OFF
*
* As well as the data packet required to display "000000", with all annunciators off.
*
*
*/
#define NEG(r) (r[MODES_BYTE] & (1 << 7)) == (1 << 7)
#define BAT(r) (r[MODES_BYTE] & (1 << 6)) == (1 << 6) // -- on BATtery, presumably.
#define RCL(r) (r[MODES_BYTE] & (1 << 5)) == (1 << 5) // -- ReCaLL (playback) mode.
#define ___AC(r) (r[MODES_BYTE] & (1 << 4)) == (1 << 4) // -- AC mode (Volts, Amps, dB)
#define DB(r) (r[MODES_BYTE] & (1 << 3)) == (1 << 3) // -- DB measure rel. to 1 dBmW @ 660 Ohms
#define STO(r) (r[MODES_BYTE] & (1 << 2)) == (1 << 2) // -- STOre (record) mode. See manual.
#define REL(r) (r[MODES_BYTE] & (1 << 1)) == (1 << 1) // -- RELative. Used to zero probes in 2-wire.
#define AUTO(r) (r[MODES_BYTE] & (1 << 0)) == (1 << 0) // -- AUTOranging. Volts and Ohms only.
#define RMT(r) 0 // -- REMOTE - under GPIB control.
#define __A(r) (r[UNITS_BYTE] & (1 << 7)) == (1 << 7) // -- Amps (NOTE: ONLY AFTER unit2_byte is masked and merged to here);
#define __O(r) (r[UNITS_BYTE] & (1 << 6)) == (1 << 6) // -- Ohms (NOTE: ONLY AFTER unit2_byte is masked and merged to here);
#define __V(r) (r[UNITS_BYTE] & (1 << 3)) == (1 << 3) // Volts
#define _mA(r) (__A(r) && ( (r[UNITS_BYTE] & (1 << 5)) == (1 << 5))) // milliAmps
#define _kO(r) (__O(r) && ( (r[UNITS_BYTE] & (1 << 4)) == (1 << 4))) // kiloOhms
#define _uA(r) (__A(r) && ( (r[UNITS_BYTE] & (1 << 2)) == (1 << 2))) // microAmps
#define _MO(r) (__O(r) && ( (r[UNITS_BYTE] & (1 << 1)) == (1 << 1))) // MegaOhms
#define _mV(r) (__V(r) && ( (r[UNITS_BYTE] & (1 << 0)) == (1 << 0))) // milliVolts
#define RMT(r) (r[UNIT2_BYTE] & (1 << 5)) == (1 << 5) // REMote control using GPIB.
#define __A_old(r) (r[UNIT2_BYTE] & (1 << 2)) == (1 << 2) // Amps
#define __O_old(r)_old (r[UNIT2_BYTE] & (1 << 1)) == (1 << 1) // Ohms
#define CAL(r) (r[UNIT2_BYTE] & (1 << 0)) == (1 << 0) // -- CALibration process.
#define DIGIT_HAS_DOT(x) ((x & 4) == 4)
String get_mode(byte DMMReading[], bool lcd);
String get_units(byte DMMReading[], bool lcd);
String get_digits(byte DMMReading[], bool lcd);
byte merge_units(byte pkt[]);