#!schedule.py
from datetime import datetime
from datetime import date
import time
# App-specific modules
import events
import devices
import log
import variables
import iottime
import database
import config
import zcl
import heating
overrideTimeoutMins = 0 # Not overriding initially
currentTargetTemp = 0 # Force schedule to be read in the first minute
def EventHandler(eventId, eventArg):
global overrideTimeoutMins, currentTargetTemp
if eventId == events.ids.MINUTES:
name = config.Get("HeatingDevice")
if name != None:
heatingDevKey = devices.FindDev(name) # Get heating device every minute to allow for it changing
if heatingDevKey != None: # Check that we have a real heating device
schedule = config.Get("HeatingSchedule")
if schedule != None:
scheduledTargetTemp = GetTarget(schedule)
if scheduledTargetTemp != None: # We now have a heating device and a schedule to follow or override
if overrideTimeoutMins > 0:
overrideTimeoutMins = overrideTimeoutMins-1
if overrideTimeoutMins <= 0: # Just finished override
database.NewEvent(heatingDevKey, "Resume "+str(scheduledTargetTemp)+"'C") # For ActivityLog on web page
currentTargetTemp = heating.SetTargetTemp(heatingDevKey, scheduledTargetTemp) # Resume schedule here
else: # Still overriding
if scheduledTargetTemp != currentTargetTemp: # Check whether schedule in heating device is about to change target
database.NewEvent(heatingDevKey, "Overriding scheduled "+str(scheduledTargetTemp)+"'C with "+str(currentTargetTemp)+"C") # For ActivityLog on web page
# Un-indent following line to force override temp once/min while overriding, rather than just at change
heating.SetTargetTemp(heatingDevKey, currentTargetTemp) # Re-Set target in heating device (since it's also running the schedule)
else: # Not overriding
if scheduledTargetTemp != currentTargetTemp:
database.NewEvent(heatingDevKey, "Scheduled "+str(scheduledTargetTemp)+"'C") # For ActivityLog on web page
#heating.SetTargetTemp(heatingDevKey, scheduledTargetTemp) # Set target in heating device here. (Not needed since it's running the schedule directly)
currentTargetTemp = scheduledTargetTemp
# else: No scheduled target
# else: No HeatingSchedule
# else: Despite having a name, there's no associated device
variables.Set("TargetTemp", str(currentTargetTemp))
else: # Ignore schedules and overrides if no named heating device
synopsis.problem("NoHeatingDevice", "No HeatingDevice entry in config, needed to resume after override")
def Override(devKey, targetC, timeSecs):
global overrideTimeoutMins, currentTargetTemp
timeMins = int(int(timeSecs)/60)
if timeMins > 0:
overrideTimeoutMins = timeMins
database.NewEvent(devKey, "Override "+str(targetC)+"'C") # For web page. Update event log so I can check my schedule follower works
currentTargetTemp = heating.SetTargetTemp(devKey, targetC) # Set target in heating device here
def GetTarget(scheduleName):
timeOfDay = datetime.now().strftime("%H:%M")
dayOfWeek = iottime.GetDow(date.today().isoweekday() % 7) # So that Sun=0, Mon=1, etc.
scheduleStr = database.GetSchedule(scheduleName, dayOfWeek) # Get schedule for today
if scheduleStr == None:
log.fault("No schedule found on "+str(dayOfWeek))
return None
log.debug("Resuming using schedule for today("+str(dayOfWeek)+") is "+scheduleStr)
try:
scheduleList = eval(scheduleStr)
except:
log.fault("Bad schedule - Can't turn "+scheduleStr+" into a list")
return None # Bad list from database
target = 7 # Should really be the last scheduled temperature from the previous day's schedule
numSetpoints = len(scheduleList)
for index in range(0, numSetpoints):
timeTemp = scheduleList[index] # Get each time & temp from schedule
timeStr = timeTemp[0]
tempStr = timeTemp[1]
#log.debug("Checking whether "+str(timeOfDay)+" is greater than "+str(timeStr))
if iottime.MakeTime(timeOfDay) >= iottime.MakeTime(timeStr):
target = tempStr # Remember last target
return target # If we reach the end of today's schedule, then assume our time is after last change, so use last target