mapper [rollup_metadata.continuous.next_window_end_time] cannot be changed from type [long] to [date]
version conflict, required seqNo [7], primary term [1]. current document has seqNo [8] and primary term [1]","index":".opendistro-ism-config","shard":"3","index_uuid":"mqJmMNSZTA20CFiqJLw5Ag"
Rollup is not STARTED expected:<started> but was:<finished>
Refer to the analysis #90 (comment) which provides a clear path forward to fix such flaky scenario
The text was updated successfully, but these errors were encountered:
bowenlan-amzn
changed the title
[Flaky Test] mapper [rollup_metadata.continuous.next_window_end_time] cannot be changed from type [long] to [date]
[Flaky Test] rollup test flaky because didn't assert job finish properly
Nov 20, 2023
Flaky symptom:
mapper [rollup_metadata.continuous.next_window_end_time] cannot be changed from type [long] to [date]
version conflict, required seqNo [7], primary term [1]. current document has seqNo [8] and primary term [1]","index":".opendistro-ism-config","shard":"3","index_uuid":"mqJmMNSZTA20CFiqJLw5Ag"
Rollup is not STARTED expected:<started> but was:<finished>
Refer to the analysis #90 (comment) which provides a clear path forward to fix such flaky scenario