Notifications
You must be signed in to change notification settings - Fork 0
/
pump.py
571 lines (467 loc) · 19.2 KB
/
pump.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
'''Communication with New Era pump series using a RS-232 interface.
This file is part of the EARS project <https://github.com/nalamat/ears>
Copyright (C) 2017-2021 Nima Alamatsaz <nima.alamatsaz@gmail.com>
Original project repository: https://bitbucket.org/bburan/new-era
Copyright (C) 2011-2012 Brad Buran <bburan@alum.mit.edu>
'''
import re
import sys
import socket
import struct
import logging
import threading
from select import select
log = logging.getLogger(__name__)
SIM = '--sim' in sys.argv
if not SIM:
import serial
def convert(value, src_unit, dest_unit):
MAP = {
('ul', 'ml'): lambda x: x*1e-3,
('ml', 'ul'): lambda x: x*1e3,
('ul/min', 'ml/min'): lambda x: x*1e-3,
('ul/min', 'ul/h'): lambda x: x*60.0,
('ul/min', 'ml/h'): lambda x: x*60e-3,
('ml/min', 'ul/min'): lambda x: x*1e3,
('ml/min', 'ul/h'): lambda x: x*60e3,
('ml/min', 'ml/h'): lambda x: x*60,
('ul/h', 'ml/h'): lambda x: x*1e-3,
}
if src_unit == dest_unit:
return value
return MAP[src_unit, dest_unit](value)
#####################################################################
# Custom-defined pump error messages
#####################################################################
class PumpError(Exception):
'''
General pump error
'''
def __init__(self, code, mesg=None):
self.code = code
self.mesg = mesg
def __str__(self):
result = '%s\n\n%s' % (self._todo, self._mesg[self.code])
if self.mesg is not None:
result += ' ' + self.mesg
return result
class PumpCommError(PumpError):
'''
Handles error messages resulting from problems with communication via the
pump's serial port.
'''
_mesg = {
# Actual codes returned by the pump
'' : 'Command is not recognized',
'NA' : 'Command is not currently applicable',
'OOR' : 'Command data is out of range',
'COM' : 'Invalid communications packet received',
'IGN' : 'Command ignored due to new phase start',
# Custom codes
'NR' : 'No response from pump',
'SER' : 'Unable to open serial port',
'UNK' : 'Unknown error',
}
_todo = 'Unable to connect to pump. Please ensure that no other ' + \
'programs that utilize the pump are running and try ' + \
'try power-cycling the entire system (rack and computer).'
class PumpHardwareError(PumpError):
'''Handles errors specific to the pump hardware and firmware.'''
_mesg = {
'R' : 'Pump was reset due to power interrupt',
'S' : 'Pump motor is stalled',
'T' : 'Safe mode communication time out',
'E' : 'Pumping program error',
'O' : 'Pumping program phase out of range',
}
_todo = 'Pump has reported an error. Please check to ensure pump ' + \
'motor is not over-extended and power-cycle the pump.'
class PumpUnitError(Exception):
'''Occurs when the pump returns a value in an unexpected unit
'''
def __init__(self, expected, actual, cmd):
self.expected = expected
self.actual = actual
self.cmd = cmd
def __str__(self):
mesg = '%s: Expected units in %s, receved %s'
return mesg % (self.cmd, self.expected, self.actual)
class PumpInterface(object):
'''
Establish a connection with the New Era pump.
'''
#####################################################################
# Basic information required for creating and parsing RS-232 commands
#####################################################################
# Hex command characters used to indicate state of data
# transmission between pump and computer.
ETX = '\x03' # End of packet transmission
STX = '\x02' # Start of packet transmission
CR = '\x0D' # Carriage return
# The Syringe Pump uses a standard 8N1 frame with a default baud rate of
# 19200. These are actually the default parameters when calling the command
# to init the serial port, but I define them here for clarity (especially if
# they ever change in the future).
CONNECTION_SETTINGS = dict(baudrate=19200, bytesize=8, parity='N',
stopbits=1, timeout=.05, xonxoff=0, rtscts=0, writeTimeout=1,
dsrdtr=None, interCharTimeout=None)
STATUS = dict(I='infusing', W='withdrawing', S='halted', P='paused',
T='in timed pause', U='waiting for trigger', X='purging')
# Map of trigger modes. Dictionary key is the value that must be provided
# with the TRG command sent to the pump. Value is a two-tuple indicating
# the start and stop trigger for the pump (based on the TTL input). The
# trigger may be a rising/falling edge, a low/high value or None. If you
# set the trigger to 'falling', None', then a falling TTL will start the
# pump's program with no stop condition. A value of 'rising', 'falling'
# will start the pump when the input goes high and stop it when the input
# goes low.
TRIG_MODE = {
'FT': ('falling', 'falling'),
'FH': ('falling', 'rising'),
'F2': ('rising', 'rising'),
'LE': ('rising', 'falling'),
'ST': ('falling', None),
'T2': ('rising', None),
'SP': (None, 'falling'),
'P2': (None, 'falling'),
'RL': ('low', None),
'RH': ('high', None),
'SL': (None, 'low'),
'SH': (None, 'high'),
}
REV_TRIG_MODE = dict((v, k) for k, v in TRIG_MODE.items())
DIR_MODE = {
'INF': 'infuse',
'WDR': 'withdraw',
'REV': 'reverse',
}
REV_DIR_MODE = dict((v, k) for k, v in DIR_MODE.items())
RATE_UNIT = {
'UM': 'ul/min',
'MM': 'ml/min',
'UH': 'ul/h',
'MH': 'ml/h',
}
REV_RATE_UNIT = dict((v, k) for k, v in RATE_UNIT.items())
VOL_UNIT = {
'UL': 'ul',
'ML': 'ml',
}
REV_VOL_UNIT = dict((v, k) for k, v in VOL_UNIT.items())
# The response from the pump always includes a status flag which indicates
# the pump state (or error). Response is in the format
# <STX><address><status>[<data>]<ETX>
_basic_response = re.compile(STX + '(?P<address>\d+)' + \
'(?P<status>[IWSPTUX]|A\?)' + \
'(?P<data>.*)' + ETX)
# Response for queries about volume dispensed. Returns separate numbers for
# infuse and withdraw. Format is I<float>W<float><units>
_dispensed = re.compile('I(?P<infuse>[\.0-9]+)' + \
'W(?P<withdraw>[\.0-9]+)' + \
'(?P<units>[MLU]{2})')
#####################################################################
# Special functions for controlling pump
#####################################################################
def __init__(self, start_trigger='rising', stop_trigger='falling',
volume_unit='ml', rate_unit='ml/min', port='COM1'):
if SIM: return
self._port = port
self._lock = threading.Lock()
self.connect()
# We do not currently support changing the units of the pump on-the-fly.
# They must be initialized here.
self.rate_unit = rate_unit
self.volume_unit = volume_unit
self.rate_unit_cmd = self.REV_RATE_UNIT[rate_unit]
self.volume_unit_cmd = self.REV_VOL_UNIT [volume_unit]
self._lastInfused = 0
self._lastWithdrawn = 0
self._xmit('VOL %s' % self.volume_unit_cmd)
self.setTrigger(start=start_trigger, stop=stop_trigger)
log.debug('Connected to pump %s', self._xmit('VER'))
def connect(self):
if SIM: return
try:
# Connection is shared across all classes. Raise warning if we
# create a new instance?
if not hasattr(self, 'ser'):
cn = serial.Serial(port=self._port, **self.CONNECTION_SETTINGS)
PumpInterface.ser = cn
if not self.ser.isOpen():
self.ser.open()
# Pump baudrate must match connection baudrate otherwise we won't be
# able to communicate
self._xmit('ADR 0 B %d' % self.CONNECTION_SETTINGS['baudrate'])
# Turn audible alarm on. This will notify the user of any problems
# with the pump.
self._xmit('AL 0')
# Ensure that serial port is closed on system exit
import atexit
atexit.register(self.disconnect)
except PumpHardwareError as e:
# We want to trap and dispose of one very specific exception code,
# 'R', which corresponds to a power interrupt. This is almost
# always returned when the pump is first powered on and initialized
# so it really is not a concern to us. The other error messages are
# of concern so we reraise them.
if e.code != 'R':
raise
except NameError as e:
# Raised when it cannot find the global name 'SERIAL' (which
# typically indicates a problem connecting to COM1). Let's
# translate this to a human-understandable error.
log.exception(e)
raise PumpCommError('SER')
def disconnect(self):
'''Stop pump and close serial port.
Automatically called when Python exits.
'''
if SIM: return
try:
self.stop()
finally:
self.ser.close()
return # Don't reraise error conditions, just quit silently
def start(self):
'''
Starts the pump.
'''
if SIM: return
with self._lock:
self._xmit('RUN')
def startIfTTL(self, value=True):
'''
In contrast to `run`, the logical state of the TTL input is inspected
(high=True, low=False). If the TTL state is equal to value, the pump
program is started.
If value is True, start only if the TTL is high. If value is False,
start only if the TTL is low.
'''
if SIM: return
if self.getTTL() == value:
self.start()
def stop(self):
'''Stop the pump. Raises PumpError if the pump is already stopped.'''
if SIM: return
with self._lock:
self._xmit('STP')
def pause(self):
if SIM: return
self._trigger = self.getTrigger()
self.setTrigger(None, 'falling')
try:
self.stop()
except PumpError:
pass
def resume(self):
if SIM: return
self.setTrigger(*self._trigger)
if self._trigger[0] in ('high', 'rising'):
self.runIfTTL(True)
elif self._trigger[0] in ('low', 'falling'):
self.runIfTTL(False)
def setTrigger(self, start, stop):
'''
Set the start and stop trigger modes. Valid modes are rising, falling,
high and low. Note that not all combinations of modes are supported
(see TRIG_MODE for supported pairs).
start=None, stop='falling': pump program stops on a falling edge (start
manually or use the `run` method to start the pump)
start='rising', stop='falling': pump program starts on a rising edge and
stops on a falling edge
'''
if SIM: return
with self._lock:
cmd = self.REV_TRIG_MODE[start, stop]
self._xmit('TRG %s' % cmd)
def getTrigger(self):
'''
Get trigger mode. Returns tuple of two values indicating start and stop
condition.
'''
if SIM: return
with self._lock:
value = self._xmit('TRG')
return self.TRIG_MODE[value]
def setDirection(self, direction):
'''Set direction of the pump.
Valid directions are 'infuse', 'withdraw' and 'reverse'.
'''
if SIM: return
with self._lock:
arg = self.REV_DIR_MODE[direction]
self._xmit('DIR %s' % arg)
def getDirection(self):
'''Get current direction of the pump.
Response will be either 'infuse' or 'withdraw'.
'''
if SIM: return
with self._lock:
value = self._xmit('DIR')
return self.DIR_MODE[value]
def getRate(self, unit=None):
'''
Get current rate of the pump, converting rate to requested unit. If no
unit is specified, value is in the units specified when the interface
was created.
'''
if SIM: return
with self._lock:
value = self._xmit('RAT')
if value[-2:] != self.rate_unit_cmd:
raise PumpUnitError(self.volume_unit_cmd, value[-2:])
value = float(value[:-2])
if unit is not None:
value = convert(value, self.rate_unit, unit)
return value
def setRate(self, rate, unit=None):
'''
Set current rate of the pump, converting rate from specified unit to the
unit specified when the interface was created.
'''
if SIM: return
with self._lock:
if unit is not None:
rate = convert(rate, unit, self.rate_unit)
self._xmit('RAT %0.3f %s' % (rate, self.rate_unit_cmd))
def setVolume(self, volume, unit=None):
'''
Set current volume of the pump, converting volume from specified unit to
the unit specified when the interface was created.
'''
if SIM: return
with self._lock:
if unit is not None:
volume = convert(volume, unit, self.volume_unit)
self._xmit('VOL %0.3f' % volume)
def getVolume(self, unit=None):
'''
Get current volume of the pump, converting volume to requested unit. If
no unit is specified, value is in the units specified when the interface
was created.
'''
if SIM: return
with self._lock:
value = self._xmit('VOL')
if value[-2:] != self.volume_unit_cmd:
raise PumpUnitError(self.volume_unit_cmd, value[-2:])
value = float(value[:-2])
if unit is not None:
value = convert(value, unit, self.volume_unit)
return value
def _getDispensed(self, direction, unit=None):
if SIM: return
# Helper method for _getInfused and _getWithdrawn
result = self._xmit('DIS')
log.debug('_dispensed: %s, result: %s', self._dispensed, result)
match = self._dispensed.match(result)
if match.group('units') != self.volume_unit_cmd:
raise PumpUnitError('ML', match.group('units'), 'DIS')
else:
value = float(match.group(direction))
if unit is not None:
value = convert(value, self.volume_unit, unit)
return value
def resetDispensed(self):
'''Reset the cumulative infused/withdrawn volume.'''
if SIM: return
with self._lock:
self._lastInfused = 0
self._lastWithdrawn = 0
self._xmit('CLD INF')
self._xmit('CLD WDR')
def getInfused(self, unit=None):
'''
Get current volume withdrawn, converting volume to requested unit. If
no unit is specified, value is in the units specified when the interface
was created.
'''
if SIM: return 0
with self._lock:
return self._getDispensed('infuse', unit) + self._lastInfused
def getWithdrawn(self, unit=None):
'''
Get current volume dispensed, converting volume to requested unit. If
no unit is specified, value is in the units specified when the interface
was created.
'''
if SIM: return
with self._lock:
return self._getDispensed('withdraw', unit) + self._lastWithdrawn
def setDiameter(self, diameter, unit=None):
'''Set diameter (unit must be mm).'''
if SIM: return
with self._lock:
self._lastInfused += self._getDispensed('infuse' )
self._lastWithdrawn += self._getDispensed('withdraw')
if unit is not None and unit != 'mm':
raise PumpUnitError('mm', unit, 'DIA')
self._xmit('DIA %.2f' % diameter)
def getDiameter(self):
'''Get diameter setting in mm.'''
if SIM: return
with self._lock:
return self._xmit('DIA')
def getTTL(self):
'''Get status of TTL trigger.'''
if SIM: return
with self._lock:
data = self._xmit('IN 2')
if data == '1':
return True
elif data == '0':
return False
else:
raise PumpCommError('', 'IN 2')
def getStatus(self):
with self._lock:
return self.STATUS[self._getRawResponse('')['status']]
#####################################################################
# RS232 functions
#####################################################################
def _readline(self):
# PySerial v2.5 no longer supports the eol parameter, so we manually
# read byte by byte until we reach the line-end character. Timeout
# should be set to a very low value as well. A support ticket has been
# filed (and labelled WONTFIX).
# https://sourceforge.net/tracker/?
# func=detail&atid=446302&aid=3101783&group_id=46487
result = []
while 1:
last = self.ser.read(1).decode()
result.append(last)
if last == self.ETX or last == '':
break
return ''.join(result)
def _xmitSequence(self, *commands):
'''
Transmit sequence of commands to pump and return list of responses to
each command
'''
return [self._xmit(cmd) for cmd in commands]
def _getRawResponse(self, command):
self._send(command)
result = self._readline()
if result == '':
raise PumpCommError('NR', command)
match = self._basic_response.match(result)
if match is None:
raise PumpCommError('NR')
if match.group('status') == 'A?':
raise PumpHardwareError(match.group('data'), command)
elif match.group('data').startswith('?'):
raise PumpCommError(match.group('data')[1:], command)
return match.groupdict()
def _xmit(self, command):
'''
Transmit command to pump and return response
All necessary characters (e.g. the end transmission flag) are added to
the command when transmitted, so you only need to provide the command
string itself (e.g. "RAT 3.0 MM").
The response packet is inspected to see if the pump has an error
condition (e.g. a stall or power reset). If so, the appropriate
exception is raised.
'''
return self._getRawResponse(command)['data']
def _send(self, command):
self.ser.write((command + self.CR).encode('ascii'))