Skip to content

Latest commit

 

History

History
320 lines (233 loc) · 24.6 KB

NOAA-PMEL-OME_Extraction_Protocol_Sterivex_Centrifuge.md

File metadata and controls

320 lines (233 loc) · 24.6 KB
methodology_category project purpose analyses geographic_location broad_scale_environmental_context local_environmental_context environmental_medium target creator materials_required skills_required time_required personnel_required language issued audience publisher hasVersion license maturity level samp_vol_we_dna_ext samp_vol_we_dna_ext_unit nucl_acid_ext_lysis nucl_acid_ext_sep nucl_acid_ext nucl_acid_ext_kit nucl_acid_ext_modify dna_cleanup_0_1 dna_cleanup_method concentration concentration_method ratioOfAbsorbance260_280 pool_dna_num nucl_acid_ext_method_additional
sample extraction and purification
NOAA Pacific Marine Environmental Laboratory Ocean Molecular Ecology Program Protocols
biodiversity assessment objective [OBI:0001969]
DNA extraction [OBI:0000257]
North East Pacific Ocean [GAZ:00013765], Bering Sea [GAZ:00008990], Arctic Ocean [GAZ:00000323]
marine biome [ENVO:00000447], marine photic zone [ENVO:00000209]
marine biome [ENVO:00000447], marine photic zone [ENVO:00000209], marine benthic biome [ENVO:01000024], oceanic epipelagic zone biome [ENVO:01000035]
sea water [ENVO:00002149]
deoxyribonucleic acid (DNA) [NCIT:C449]
Shannon Brown, Han Weinrich, and Zachary Gold
vortexer [OBI:0400118], centrifuge [OBI:0400106], incubator [OBI:0000136]
sterile technique, pipetting skills, standard molecular technique
480
1
en
2024-05-30
scientists
NOAA Pacific Marine Environmental Laboratory Ocean Molecular Ecology Program; University of Washington Cooperative Institute for Climate, Ocean, & Ecosystem Studies
1
CC0 1.0 Universal
mature
1000
mL
enzymatic | thermal
column-based
Qiagen DNeasy Blood and Tissue Kit, 250
Modified for sterivex, reagent volume altered
0
not applicable
not applicable
not applicable
not applicable
not applicable
not applicable

NOAA PMEL OME Extraction Protocol for Sterivex Using a Centrifuge

PROTOCOL INFORMATION

Minimum Information about an Omics Protocol (MIOP)

Making eDNA FAIR (FAIRe)

Authors

  • All authors known to have contributed to the preparation of this protocol, including those who filled in the template.
  • Visit https://orcid.org/ to register for an ORCID.
  • Date is the date the author first worked on the protocol.
PREPARED BY All authors known to have contributed to the preparation of this protocol, including those who filled in the template. AFFILIATION ORCID (visit https://orcid.org/ to register) DATE
Shannon Brown Ocean Molecular Ecology, NOAA PMEL & UW CICOES 0000-0001-9808-2638 2024-02-02
Han Weinrich Ocean Molecular Ecology, NOAA PMEL & UW CICOES 0009-0007-6063-0986 2024-02-02
Sean McAllister Ocean Molecular Ecology, NOAA PMEL & UW CICOES 0000-0001-6654-3495 2024-02-02
Matt Galaska Ocean Molecular Ecology, NOAA PMEL 0000-0002-4257-0170 2024-02-02

Related Protocols

  • This section contains protocols that should be known to users of this protocol.
  • Internal Protocols: Derivative or altered protocols, or other protocols in this workflow.
  • External Protocols: Protcols from manufacturers or other groups.
  • Include the link to each protocol.
  • Include the version number (internal) or access date (external) of the protocol when it was accessed.

Internal Protocols

PROTOCOL NAME LINK VERSION RELEASE DATE
PPS Extraction Pending 1.0
Qiavac Extraction Pending 1.0
Qubit Protocol Pending 1.0

External Protocols

PROTOCOL NAME LINK ISSUER / AUTHOR ACCESS DATE
DNA Extraction Protocol from Sterivex Filters by Shea and Boehm Link 1.0 2023-08-01
Spens et al. 2017 Link 1.0 2016-11-15

Protocol Revision Record

  • Version numbers start at 1.0.0 when the protocol is first completed and will increase when changes that impact the outcome of the procedure are made (patches: 1.0.1; minor changes: 1.1.0; major changes: 2.0.0).
  • Release date is the date when a given protocol version was finalised.
  • Description of revisions includes a brief description of what was changed relative to the previous version.
VERSION RELEASE DATE DESCRIPTION OF REVISIONS
1.0.0 2024-05-30 Initial release
1.2.0 2025-02-20 Formatting updates to new BeBOP format

Acronyms and Abbreviations

ACRONYM / ABBREVIATION DEFINITION
eDNA environmental DNA
PCR Polymerase chain reaction
PPE Personal protective equipment
EtOH Ethanol
NTC No template control
BSC Biosafety cabinent
OME Ocean Molecular Ecology
PMEL Pacific Marine Environmental Laboratory
NOAA National Oceanic and Atmospheric Administration
UW University of Washington
CICOES Cooperative Institute for Climate, Ocean, & Ecosystem Studies
MBON Marine Biodiversity Observation Network
MBARI Monterey Bay Aquarium Research Institute
WC-OBON West Coast Ocean Biomolecular Observing Network

Glossary

SPECIALISED TERM DEFINITION
Field blank Sampling negative control. Typically distilled or reverse osmosis water run through a filter like an seawater eDNA sample to control for contamination in the field sampling step.
Extraction blank Extraction negative control. Typically nuclease-free water or empty filter run through the DNA extraction process to control for contamination in the DNA extraction step.
No template control PCR negative control. Typically nuclease-free water loaded in place of a sample on a PCR to control for contamination in the PCR step.
Positive control PCR positive control. Typically a synthetic DNA strand, non-indigenous DNA extract, or intentionally designed mock community loaded in place of a sample on a PCR to control for contamination and index hopping in the PCR step.

BACKGROUND

This document describes the required protocol to extract DNA from a sterivex filter.

Summary

Nucleic acids extraction from the sterivex filters using the Qiagen DNeasy Blood and Tissue Kit with some modifications to the manufacturer’s protocol. These extraction protocols, adapted from Spens et al 2017, are used by the NOAA PMEL Ocean Molecular Ecology (OME) Group.

Method description and rationale

The Spens et al 2017 protocol is a widely used, highly reproducible, and easily executeable DNA extraction protocol from Sterivex filters. Sterivex filters are a commonly used filter for seawater sampling including by the PMEL Ocean Molecular Ecology Program and the NOAA CalCOFI Ocean Genomics group. This extraction protocol from sterivex samples has been demonstrated to generate sufficient DNA yields while minimizing contamination (Spens et al. 2017, Shea et al. 2023).

Spatial coverage and environment(s) of relevance

This protocol has been used to extract DNA from tens of thousands of filtered sea water samples taken from coastal stations off the western coast of North America in the Northeastern Pacific Ocean, Bering Sea and Arctic Ocean (primarily off California, Oregon, Washington, and Alaska). Samples collected range in depth from surface ocean (epipelagic biome) to just off bottom (benthic biome) at varying distances from shore (coastal to off-shelf).

PERSONNEL REQUIRED

One person with molecular biology experience.

Safety

Buffer AW1 from the DNeasy Blood & Tissue Kit contains guanidine hydrochloride and is classified as category 4 for acute toxicity (Safety Data Sheet). Additional care should be taken when working with this buffer. For other reagents, standard precautions including wearing PPE should be taken to avoid skin and eye exposure to chemicals.

Training requirements

Molecular biology training (including, at a minimum, sterile technique, pipetting small volumes, and previous DNA/RNA extraction experience) is required to conduct this protocol.

Time needed to execute the procedure

Extracting DNA from 24 sterivex samples takes 8 hours (480 minutes) including incubation time.

EQUIPMENT

  • Opentrons Consumables: If using Opentrons OT-2 Robot for KF Plate Prep.
  • Description: E.g., "filter".
  • Product Name and Model: Provide the official name of the product.
  • Manufacturer: Provide the name of the manufacturer of the product.
  • Quantity: Provide quantities necessary for one application of the standard operating procedure (e.g., number of filters).
  • Remark: For example, some of the consumable may need to be sterilized, some commercial solution may need to be diluted or shielded from light during the operating procedure.
DESCRIPTION PRODUCT NAME AND MODEL MANUFACTURER QUANTITY REMARK
Durable equipment
BioSafety II cabinet Biological safety cabinet (INT-1100A2) Kewaunee 1 Can be substituted with generic; internal UV light required.
Heatshaker Fisherbrand incubating mini-shaker Fisher Scientific 1 Can be substituted with generic; hot bath not recommend for sterility reasons.
Centrifuge Eppendorf 5425 R Fisher Scientific 1 Can be substituted with generic - needs to fit 1.5 mL tubes.
Vortex Analog vortex mixer Fisher Scientific 1 Can be substituted with generic.
UV crosslinker UV crosslinker AH (115V), 234100 Boekel Scientific 1 Recommended not required; can be substituted.
-20°C freezer TSX high-performance -20°C manual defrost freezer Fisher Scientific 1 Can be substituted with generic but recommend temperature display.
Pipettor: 20 - 200 uL Pipetman P200L Gilson 1 Can be substituted with any accurate pipettor.
Pipettor: 100-1000 uL Pipetman P1000 Gilson 1 Can be substituted with any accurate pipettor.
Microtube racks 96-Well flipper microtube racks Fisher Scientific 2 Can be substituted with generic but must fit 1.5-2.0 mL tubes.
50 mL tube racks SPL snap 50 mL tube rack (25 place) SPL Life Sciences 2 Can be substituted but must fit sterivex.
4-way tube racks 4 way interlocking tube rack Cole-Parmer 4 Can be substituted with generic, must fit 12 x 5 mL tubes and 50 mL tubes.
Trash bag holder Bel-Art scienceware bench-top biohazard holders Fisher Scientific 1 Can be substituted with generic.
Wash bottles Safety wash bottles 500 mL for EtOH and bleach VWR 2 Can be substituted with generic, but recommend different colored bottles for each reagent. Must be sterilized before use.
Cryoboxes TruCool hinged lid cryoboxes VWR 4 Can be substituted with generic, but recommend set color for eDNA. Must be sterilized before use.
Consumable equipment
200 μL pipette tips TipOne RPT filter tips 200 μL graduated USA Scientific 96 Can be subsituted with generic. Must be sterile and filtered.
1000 μL pipette tips TipOne RPT filter tips 1000 μL USA Scientific 220 Can be subsituted with generic. Must be sterile and filtered.
1.5 mL tubes Snap cap DNA LoBind 1.5 mL tubes, PCR-clean Eppendorf 24 Can be substituted with generic. Must be sterile.
1.5 mL gasketed cryotubes Screw cap gasketed 1.5 mL tubes, sterile Corning 24 Can be substituted with generic. Must be sterile.
5 mL tubes DNA LoBind 5 mL PCR clean centrifuge tube Eppendorf 24 Can be subsituted with generic, must be sterile/PCR clean
50 mL falcon tubes Falcon 50 mL high clarity conical centrifuge tube Corning Falcon 3 Can be substituted with generic. Must be sterile.
Sterivex/syringe caps Male/female sterile luer caps McKesson 48 Can be subsituted with generic, must be sterile and individually packaged.
5 mL luer lock syringes BD luer lock disposable syringe BD 24 Can be subsituted with generic. Must be sterile and luer lock.
Kimwipes Delicate task wipes Kimtech 5 Can be substituted with generic. Must be lint-free.
Nitrile gloves Powder free nitrile gloves Fisher Scientific 8 Can be subsituted with generic nitrile gloves. Does not come sterile, must be sterilized before use (10% bleach followed by 70% EtOH)
Lab notebook Durable, hardcover lab notebook Generic 1 Dedicated to the lab space
Writing utensils Sharpies and pens Generic 2 Dedicated to the lab extraction space. Not made of wood - must be able to be wiped down with bleach/EtOH.
Trash bags for BSC Teivio 1.2 Gallon 360 Counts Strong Trash Bags Teivio 3 Can be substituted with generic.
QIAGEN Extraction Kit Qiagen DNeasy Blood and Tissue Kit - 250 extractions QIAGEN 1 For this protocol at scale (i.e., 250 samples), additional volumes of some buffers need to be purchased.
QIAGEN kit consumables
Spin columns Mini spin column Included in kit 24 Kit contains 250 columns - sufficient for 250 extractions using this protocol)
Collection tubes 2 mL collection tube Included in kit 48 Kit contains 500 tubes - sufficient for 250 extractions using this protocol)
QIAGEN kit chemicals
Buffer ATL QIAGEN Buffer ATL Included in kit, may need to purchase additional 17.28 (mL) Kit contains 50 mL - sufficient for 69 extractions using this protocol; require 200 mL total for 250 extractions.
Proteinase K Qiagen Proteinase K Included in kit, may need to purchase additional 1.92 (mL) Kit contains 6 mL - sufficient for 75 extractions using this protocol; require 20 mL total for 250 extractions.
Buffer AL Qiagen Buffer AL Included in kit, may need to purchase additional 21.6 (mL) Kit contains 66 mL - sufficient for 73 extractions using this protocol; require 225 mL total for 250 extractions.
Buffer AW1 Qiagen Buffer AW1 Included in kit 12 (mL) Kit contains 98 mL concentrate - sufficient for 250 extractions using this protocol. Mix with 100% molecular grade EtOH before use, instructions on bottle
Buffer AW2 Qiagen Buffer AW2 Included in kit 12 (mL) Kit contains 66 mL concentrate - sufficient for 250 extractions using this protocol. Mix with 100% molecular grade EtOH before use, instructions on bottle
Buffer AE Qiagen Buffer AE Included in kit 2.4 (mL) Kit contains 120 mL - sufficient for 1200 extractions using this protocol.
Chemicals
100% molecular grade EtOH 200 proof molecular biology grade ethanol Fisher Scientific 30 (mL) Can be substituted with generic, must be 200 proof and molecular biology grade
70% EtOH Molecular biology grade ethanol Generic 20 (mL) Don't expose to UV light.
10% bleach Hypochlorite bleach Clorox 10 (mL) Remake every ~5 days as bleach decomposes quickly at 10% concentration. Don't expose to UV light.

STANDARD OPERATING PROCEDURE

In the following SOP, please use the exact names of equipment as noted in the table above.

Provide a step-by-step description of the protocol. The identification of difficult steps in the protocol and the provision of recommendations for the execution of those steps are encouraged.

DNA extraction

Preparation

To minimize risk of sample contamination, this protocol should be carried out in dedicated eDNA extraction laboratories/rooms. When possible, the full dedicated lab space should be sterilized with UV.

Before DNA Extraction

  1. Run UV light for 30 minutes in BioSafety II cabinet (BSC) and room, if not run since last use.
  2. Sterilize workspaces and durable equipment, including pipettes within the BSC with 10% bleach. Then wipe down all surfaces and equipment with 70% EtOH. If you have a UV crosslinker available, UV pipettes and tube racks regularly for 2 minutes.
  3. Set up two 50 mL tube racks, one for sterivex and one for syringes, within the BSC by lining the bottom of the rack with kimwipes then turn on the UV light for 30 minutes to sterilize.
  4. Turn on the heatshaker to 56°C. If the Buffer ATL has percipitate, place in heatshaker. Allow the buffer to heat until all percipitate is gone (~15 minutes), swirl as needed.
  5. Aliquot ~25 mL of 100% EtOH into a 50 mL falcon tube and store at -20°C freezer for later use.
  6. Ensure 100% molecular grade EtOH has been added to Buffer AW1 and AW2 according to the Qiagen DNeasy Blood and Tissue Kit manufactorer instructions.

Recommended (not required): Aliquot Buffer AW1 and AW2 into 50 mL falcon tubes to reduce contamination caused by repeated use of large volume bottles.

Extraction

  1. Fill a sterile, 5 mL luer lock syringe with air, remove the sterivex inlet cap and dispose. Attach the syringe to the sterivex. Remove the outlet cap but don’t dispose (place on a sterile surface face up). Use the syringe to push air slowly through the filter; KEEP THE SYRINGE. If you push air through the filter 2-3x, most liquid is removed.
  2. In one 50 mL tube rack, dry the sterivex filters by placing them vertically with the ‘inlet end’ facing down. Let them blot on kimwipes previously placed on the bottom of the rack. Allow to dry while completing the next few steps.
  3. Use the saved outlet cap to seal the syringe, label it with the corresponding sample number, and place it in the other 50 mL tube rack with kimwipes.
  4. After liquid has been removed from all 24 sterivex, tap filters on separate small kimwipe to remove excess liquid post-drying. Dispose of this kimwipe and sterilize the BSC surface.
  5. Once excess ethanol has evaporated (around 30-45 minutes), reseal 4-12 sterivex at a time with their corresponding outlet cap, which is currently on the labeled 5 mL luer lock syringe. Syringes can be placed back on the 50 mL tube rack with no cap. Use a 4-way tube rack to hold sterivex for the next step.
  6. Add 720 µL Buffer ATL (pre-heated if percipitate was present) and 80 µL Proteinase K to each sterivex with the 1000 μL and 200 μL pipettes, respectively. Pipet solution between the outside of the filter and the capsule walls. Close with a new inlet cap. Handshake vigorously and/or vortex sideways.
  7. Add this batch of sterivex to the heatshaker, and complete Step 2-3 for remaining sterivex. Turn on the shaking function to 650 rpm.
  8. Incubate sterivex at 56°C for 2-3 hours. Rotate filter capsules 3-4x during incubation to ensure the entire filter surface is submerged in solution.
  9. Once all samples are removed from the BSC and inside the heatshaker, wipe down work surfaces with 10% bleach followed by 70% EtOH. Run the UV light inside the BSC for 30 minutes before samples are finished incubating.

Note: This is a good time to pre-label your 5 mL tubes, collection tubes, and 1.5 mL tubes. Ensure that all intermediate sample containers (i.e. spin coumns, 5 mL tubes) are labeled with at least the sample number on the top.

  1. Remove sterivex from the heatshaker and shake vigorously.
  2. Then, remove ALL the liquid from the inlet end of the sterivex using the corresponding 5 mL luer lock syringe. Transfer to a labeled 5 mL tube. Dispose of syringe and caps.
  3. Visually estimate the volume of the sample using the 5 mL tube markings. Record these values in lab notebook.
  4. Add Buffer AL and ice-cold 100% EtOH (i.e., aliquot you stored in the -20°C freezer) to the sample in equal volumes. Sample:Buffer:Ethanol = 1:1:1. Vortex vigorously 10-15 seconds.
  5. Pipet the mixture (max 640 µL) into a spin columns in a 2 mL collection tube provided by the DNeasy Blood and Tissue kit.
  6. Spin in the centrifuge at 6000 ∗ g for 1 min. Discard flow through. Tap collection tubes on a kimwipe to remove droplets before replacing column in collection tube.
  7. Repeat steps 14-15 until the full samples volume is filtered through each spin column (takes 4-5x).
  8. Move Buffer AE to heatshaker set at 56°C to preheat for final elution. Shaking function should be turned off.
  9. Place the spin column in a new 2 ml collection tube, add 500 µl Buffer AW1, and centrifuge for 1 min at 6000 ∗ g.
  10. Discard flow-through and collection tube. Place the spin column in a new 2 ml collection tube, add 500 µl Buffer AW2, and centrifuge for 3.5 min at 20,000 ∗ g.

Note: If there is liquid between spin column and collection tube, or if the membrane touches the filtrate, move to a new collection tube and respin the sample. Record in lab notebook.

  1. Discard flow-through and collection tube. Transfer spin column to a new, labeled 1.5 mL tube with the cap open.
  2. Add 50 µl pre-heated Buffer AE onto spin column membrane. Incubate for 5 min and then centrifuge for 1 min at 6,000 ∗ g. Without discarding flow-through, repeat with another 50 µl Buffer AE, and centrifuge. Discard the spin column, as your extract is now in the 1.5 mL tube.
  3. Place extracted DNA tubes into a labeled cryobox and store in a -20°C freezer until later use. Preferably, set aside an aliquot for long term and backup storage to be archived in a -80°C freezer (see quality control for more information)

Note: Tubes containing DNA aliquots should be labeled on both the top and side with at least the sample number. OME also labels the sides of storage tubes with the cruise number and date of extraction.

Quality control

A negative control (field blank or extraction blank) is included in every 24 set of extractions (i.e., 23 samples + NC). Samples and controls are quantified to verify DNA concentration. [NOAA-PMEL-OME-Qubit-Protocol pending]. Lastly, samples are PCR amplified alongside no-template and positive controls.

Recommended (not required): OME splits all DNA extracts into three aliquots: a working stock for immediate use at -20°C (~20-30 µl) in a 1.5 mL tube; a backup stock at -20°C in case the working stock is finished or contaminated (~30-40 uL) in a 1.5 mL tube; and an archival stock in a 1.5 mL gasketed cryotubes and frozen at -80°C indefinitely (~40 µl). All are stored in labeled cryoboxes.

Basic troubleshooting guide

Issue 1: Column clogging when pipetting sample/Buffer AL/EtOH mixture to spin columns

Solution: If a sample is turbid, solids may survive the digestion and lysis steps. These solids can clog the spin column and trap liquid above the filter. If repeating the spin down step does not fully drain liquid from the column, use a second fresh column for the remainder of the sample. Both spin columns are then run through the protocol and the eluted DNA is combined.

Issue 2: Bubbling of ATL out of sterivex upon addition

Solution 2: If the pipette tip is improperly seated in the inlet of the sterivex when adding buffer ATL, the buffer can spray upwards out of the inlet, introducing potential contamination to other samples. Ensure that the pipette tip is fully seated inside the inlet and add buffer slowly to avoid overpressuring the sterivex. Suggest tilting the sterivex slightly to ensure the seal isn't too tigh.

Issue 3: Liquid on sides of collection tube after centrifuge step following Buffer AW2 addition

Solution 3: Re-run the spin down step in a fresh spin column. No additional buffer AW2 is added. If the issue persists, move to a new collection tube and respin.

Record troubleshooting notes and issues in the lab notebook.

REFERENCES

Spens, J., Evans, A. R., Halfmaerten, D., Knudsen, S. W., Sengupta, M. E., Mak, S. S. T., Sigsgaard, E. E., & Hellström, M. (2017). Comparison of capture and storage methods for aqueous macrobial eDNA using an optimized extraction protocol: advantage of enclosed filter. Methods in Ecology and Evolution, 8 (5), 635-645. https://doi.org/10.1111/2041-210X.12683

APPENDIX A: DATASHEETS

OME_Extraction_Protocol_Sterivex_Centrifuge_ProtocolSheet_Draft1

APPENDIX B: VIDEO & IMAGE FILES

NOAA-PMEL-OME_Extraction_Protocol_Centrifuge_SterivexDiagrams