Notifications
You must be signed in to change notification settings - Fork 4
/
Copy pathwh_4.py
135 lines (114 loc) · 8.38 KB
/
wh_4.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
# -*- coding: utf-8 -*-
"""
Created on Tue Oct 24 08:38:56 2017
super simple water heater model
@author: chuck booten, jeff maguire, xin jin
"""
from WH_Response import WHResponse
class WaterHeater():
def __init__(self, Tamb = 50, RHamb= 45, Tmains = 50, hot_draw = 0, control_signal = 'none', Capacity = 50, Type = 'ER', Location = 'Conditioned', service_calls_accepted = 0, max_service_calls = 100, time_step = 60, forecast_draw = 0):
#Declare constants
self.Tdeadband = 1 #delta F
self.E_heat = 4.5 #kW
self.UA = 10 #W/K
self.Tmin = 105 # deg F
self.Tmax = 160 # deg F
self.Capacity = Capacity # gallons
self.max_service_calls = int(max_service_calls)
def execute(self,Ttank, Tset, Tamb, RHamb, Tmains, hot_draw, control_signal, Type, service_calls_accepted, Element_on, timestep, forecast_draw, IsForecast):
(response) = self.WH(Ttank, Tset,Tamb,Tmains,hot_draw, control_signal, Type, Element_on, service_calls_accepted, self.max_service_calls, timestep, forecast_draw, IsForecast)
return response #Ttank, Tset, SoC, AvailableCapacityAdd, AvailableCapacityShed, service_calls_accepted, Eservice, is_available_add, is_available_shed, ElementOn, Eused, PusedMax
def WH(self,Tlast, Tset, Tamb_ts,Tmains_ts,hot_draw_ts, control_signal_ts, Type, Element_on_ts, service_calls_accepted_ts, max_service_calls, timestep, forecast_draw, is_forecast):
#############################################################################
response = () #initialize
# Baseline operation
Eloss_ts = self.UA*(Tlast-Tamb_ts)
dT_from_hot_draw = (hot_draw_ts)/self.Capacity*(Tlast - Tmains_ts)# hot_draw is in gal for the timestep
dT_loss = Eloss_ts*timestep*60/(3.79*self.Capacity*4810) #3.79 kg/gal of water, 4810 is J/kgK heat capacity of water, timestep units are minutes
Edel_ts = hot_draw_ts * 4180 * 3.79 * (Tlast-Tmains_ts)
if Tlast < Tset - self.Tdeadband:
Eused_baseline_ts = self.E_heat*1000 #W used
Element_on_ts = 1
elif Element_on_ts == 1 and Tlast < Tset + self.Tdeadband:
Eused_baseline_ts = self.E_heat*1000 #W used
Element_on_ts = 1
else:
Eused_baseline_ts = 0
Element_on_ts = 0
###########################################################################
#modify operation based on control signal
if control_signal_ts < 0 and Tlast > self.Tmin and max_service_calls > service_calls_accepted_ts and Element_on_ts == 1: #Element_on_ts = 1 requirement eliminates free rider situation
Eused_ts = 0 #make sure it stays off
Element_on_ts = 0
service_calls_accepted_ts += 1
elif control_signal_ts < 0 and Tlast < self.Tmin:
# don't change anything
Eused_ts = Eused_baseline_ts
elif control_signal_ts > 0 and Tlast > self.Tmax:
Eused_ts = 0 #make sure it stays off
Element_on_ts = 0
elif control_signal_ts > 0 and Tlast < self.Tmax and max_service_calls > service_calls_accepted_ts and Element_on_ts == 0: #Element_on_ts = 0 requirement eliminates free rider situation
#make sure it stays on
Eused_ts = self.E_heat*1000 #W used
Element_on_ts = 1
service_calls_accepted_ts += 1
else:#no changes
Eused_ts = Eused_baseline_ts
#calculate energy provided as a service, >0 is load add, <0 load shed
# if the magnitude of the service that could be provided is greater than what is requested, just use what is requested and adjust the element on time
# print('Available',abs(Eused_ts-Eused_baseline_ts), 'requested',control_signal_ts)
if abs(Eused_ts-Eused_baseline_ts) > abs(control_signal_ts):
Eservice_ts = control_signal_ts
Eused_ts = control_signal_ts + Eused_baseline_ts
Element_on_ts = control_signal_ts/(Eused_ts-Eused_baseline_ts)
else: # assumes WH can't meet the entire request so it just does as much as it can
Eservice_ts = Eused_ts-Eused_baseline_ts
#could change this at some point based on signals
Tset_ts = Tset
dT_power_input = Eused_ts*timestep*60/(3.79*self.Capacity*4810)#timestep is in minutes so mult by 60 to get seconds
Ttank_ts = Tlast + dT_power_input - dT_loss - dT_from_hot_draw
# Calculate more parameters to be passed up
SOC = (Ttank_ts - self.Tmin)/(self.Tmax - self.Tmin)
######################################################################################
#simple method to forecast availability for providing a service during next timestep
# isAvailable_ts = 1 if max_service_calls > service_calls_accepted_ts else 0
#more advanced method for estimating availaibility based on the aggregator providing a fleet average water draw for the next timestep.
dT_from_forecast_draw = -(forecast_draw)/self.Capacity*(Ttank_ts - Tmains_ts)
Ttank_forecast = Ttank_ts + dT_from_forecast_draw
isAvailable_add_ts = 1 if max_service_calls > service_calls_accepted_ts and Ttank_forecast < self.Tmax and (Ttank_forecast > Tset - self.Tdeadband and Element_on_ts == 0 or Ttank_forecast > Tset + self.Tdeadband) > 0 else 0 #haven't exceeded max number of calls, plus it isn't expected that the element would already be on due to the forecast temperature being below Tset- Tdeadband but are still expected to be below Tmax
isAvailable_shed_ts = 1 if max_service_calls > service_calls_accepted_ts and Ttank_forecast > self.Tmin and (Ttank_forecast < Tset + self.Tdeadband and Element_on_ts > 0 or Ttank_forecast < Tset - self.Tdeadband) > 0 else 0 #haven't exceeded max number of calls, plus it is expected that the element would already be on due to the forecast temperature being below Tset + Tdeadband but are still expected to be above Tmin
######################################################################################
#estimate on what the maximum power usage could be based on initial temps, expected dT from water draw, dT loss and COP
if Type == "HP":
COP = 2.5 #this shouldn't be constant, just a placeholder for now
else: #assumes electric resistance
COP = 1
Texpected = Tlast - dT_from_hot_draw - dT_loss
PusedMax_ts = (self.Tmax - Texpected)*(3.79*self.Capacity*4810)/COP/(60*timestep) # units: [W] 3.79 kg/gal of water, 4810 is J/kgK heat capacity of water
Available_Capacity_Add = (1-SOC)*self.Capacity*3.79*4180*(self.Tmax - self.Tmin)*isAvailable_add_ts/(timestep*60) #/timestep converts from Joules to Watts, 3.79 = kg/gal, 4180 heat cap of water J/kgK
Available_Capacity_Shed = SOC*self.Capacity*3.79*4180*(self.Tmax - self.Tmin)*isAvailable_shed_ts/(timestep*60) #/timestep*60 converts from Joules to Watts,
######################################################################################
# if this is just a forecast, reset the tank to the conditions from the last step
if is_forecast == 1:
Ttank_ts = Tlast
SOC = (Ttank_ts - self.Tmin)/(self.Tmax - self.Tmin)
Available_Capacity_Add = (1-SOC)*self.Capacity*3.79*4180*(self.Tmax - self.Tmin)*isAvailable_add_ts/(timestep*60) #/timestep converts from Joules to Watts, 3.79 = kg/gal, 4180 heat cap of water J/kgK
Available_Capacity_Shed = SOC*self.Capacity*3.79*4180*(self.Tmax - self.Tmin)*isAvailable_shed_ts/(timestep*60) #/timestep*60 converts from Joules to Watts,
service_calls_accepted_ts = service_calls_accepted_ts - 1
response = WHResponse()
response.Ttank = Ttank_ts
response.Tset = Tset_ts
response.Eused = Eused_ts
response.PusedMax = PusedMax_ts
response.Eloss = Eloss_ts
response.ElementOn = Element_on_ts
response.Eservice = Eservice_ts
response.SOC = SOC
response.AvailableCapacityAdd = Available_Capacity_Add
response.AvailableCapacityShed = Available_Capacity_Shed
response.ServiceCallsAccepted = service_calls_accepted_ts
response.IsAvailableAdd = isAvailable_add_ts
response.IsAvailableShed = isAvailable_shed_ts
return response