Skip to content
This repository has been archived by the owner on Jun 12, 2024. It is now read-only.

Commit

Permalink
README.md: refine documentation
Browse files Browse the repository at this point in the history
Signed-off-by: Jérôme Benoit <jerome.benoit@sap.com>
  • Loading branch information
Jérôme Benoit committed Mar 5, 2022
1 parent e819162 commit d2971a4
Showing 1 changed file with 3 additions and 3 deletions.
6 changes: 3 additions & 3 deletions README.md
Original file line number Diff line number Diff line change
Expand Up @@ -86,7 +86,7 @@ But the modifications to test have to be done to the files in the build result d

| Key | Value(s) | Default Value | Value type | Description |
| --------------------------------- | ---------- | --------------- | --------------------------------- | ------------------------------------------------------------------------------------------------------------------------------------- |
| supervisionUrls | | '' | string\|string[] | string or array of connection URIs to OCPP-J servers. It has priority over the global configuration parameter |
| supervisionUrls | | '' | string \| string[] | string or array of connection URIs to OCPP-J servers. It has priority over the global configuration parameter |
| supervisionUser | | '' | string | basic HTTP authentication user to OCPP-J server |
| supervisionPassword | | '' | string | basic HTTP authentication password to OCPP-J server |
| supervisionUrlOcppConfiguration | true/false | false | boolean | Allow supervision URL configuration via a vendor OCPP parameter key |
Expand All @@ -103,13 +103,13 @@ But the modifications to test have to be done to the files in the build result d
| chargePointVendor | | '' | string | charging stations vendor |
| chargeBoxSerialNumberPrefix | | '' | string | charging stations serial number prefix |
| firmwareVersion | | '' | string | charging stations firmware version |
| power | | | float\|float[] | charging stations maximum power value(s) |
| power | | | float \| float[] | charging stations maximum power value(s) |
| powerSharedByConnectors | true/false | false | boolean | charging stations power shared by its connectors |
| powerUnit | W/kW | W | string | charging stations power unit |
| currentOutType | AC/DC | AC | string | charging stations current out type |
| voltageOut | | AC:230/DC:400 | integer | charging stations voltage out |
| numberOfPhases | 0/1/3 | AC:3/DC:0 | integer | charging stations number of phase(s) |
| numberOfConnectors | | | integer\|integer[] | charging stations number of connector(s) |
| numberOfConnectors | | | integer \| integer[] | charging stations number of connector(s) |
| useConnectorId0 | true/false | true | boolean | use connector id 0 definition from the template |
| randomConnectors | true/false | false | boolean | randomize runtime connector id affectation from the connector id definition in template |
| resetTime | | 60 | integer | seconds to wait before the charging stations come back at reset |