layout | title | permalink |
---|---|---|
page |
Q311226: EU and Admin Client Traps If OU Name Longer than 64 Characters |
/kb/311/Q311226/ |
{% raw %}
Article: Q311226
Product(s): Microsoft SNA Server
Version(s):
Operating System(s):
Keyword(s): kbDSupport
Last Modified: 03-NOV-2001
-------------------------------------------------------------------------------
The information in this article applies to:
- Microsoft Host Integration Server 2000
-------------------------------------------------------------------------------
SYMPTOMS
========
When the Host Integration Server 2000 End-User (EU) Client or Admin Client is
configured with a long organizational unit (OU) name, the SNA Resource Location
Wizard will terminate abnormally due to an access violation.
If Dr.Watson is configured as the default debugger, you will get a DRWTSN32.log
similar to the following:
Application exception occurred:
App: HICliCfg.exe (pid=624)
When: 10/22/2001 @ 15:46:43.986
Exception number: c0000005 (access violation)
State Dump for Thread Id 0x308
eax=0000006a ebx=77e16345 ecx=0006f098 edx=00000001 esi=002381c0 edi=ffffff31
eip=6c00554f esp=0006f014 ebp=0006f020 iopl=0 nv up ei pl nz na pe nc
cs=001b ss=0023 ds=0023 es=0023 fs=0038 gs=0000 efl=00000202
CAUSE
=====
The SNA Resource Location Wizard uses a static string to store the OU name. The
string is defined to contain a maximum of 64 characters. If the OU name is
longer than this, an access violation results.
STATUS
======
Microsoft has confirmed this to be a problem in Host Integration Server 2000.
Additional query words:
======================================================================
Keywords : kbDSupport
Technology : kbAudDeveloper kbHostIntegServ2000
Version : :
Issue type : kbbug
Solution Type : kbnofix
=============================================================================