Skip to content

Latest commit

 

History

History

Q246017

Folders and files

NameName
Last commit message
Last commit date

parent directory

..
 
 
layout title permalink
page
Q246017: SNA Print Session Remains Pending When Stopped and Restarted
/kb/246/Q246017/

Q246017: SNA Print Session Remains Pending When Stopped and Restarted

{% raw %}

Article: Q246017
Product(s): Microsoft SNA Server
Version(s): WINDOWS:4.0 SP3
Operating System(s): 
Keyword(s): 
Last Modified: 08-MAY-2002

-------------------------------------------------------------------------------
The information in this article applies to:

- Microsoft SNA Server, version 4.0 SP3 
-------------------------------------------------------------------------------

SYMPTOMS
========

When you stop and restart an APPC printer session, the printer session may
remain in a Pending status.

CAUSE
=====

The SNA Server Print server does not issue a TP_ENDED when the session is
stopped. Therefore, the AS/400 writer is still active.

STATUS
======

Microsoft has confirmed this to be a problem in Microsoft SNA Server version 4.0
SP3.


MORE INFORMATION
================

A TP_ENDED is issued when the print session is closed, as in the following
trace:

  APPC
  ---------------------------------------------------------------------------
  APPC TP_ENDED request
  APPC
  APPC Type:Sync VerbID:00068000
  APPC
  APPC ---- Verb Parameter Block at address 0EF4B8E0 ----
  APPC 13000000 00000000 00000000 00000000 [..............]
  APPC 409B2400 01000000 [@.$.....]
  APPC
  ---------------------------------------------------------------------------
  APPC RECEIVE_AND_WAIT response, result = DEALLOC_ABEND
  APPC
  APPC Type:Sync VerbID:000F4000
  APPC
  APPC ---- Verb Parameter Block at address 0EF4B854 ----
  APPC 0B000000 00050000 00000000 00000000 [................]
  APPC 409B2400 70A22400 00040001 00000010 [@.$.ps$.........]
  APPC 00000000 C4BD2300 00000000 00000000 [....D.#.........]
  APPC
  ---------------------------------------------------------------------------
  APPC TP_ENDED response, result = OK
  APPC
  APPC Type:Sync VerbID:00068000
  APPC
  APPC ---- Verb Parameter Block at address 0EF4B8E0 ----
  APPC 13000000 00000000 00000000 00000000 [...............]
  APPC 409B2400 01000000 [@.$..... ]
  APPC
  ---------------------------------------------------------------------------
  APPC TP_STARTED request
  APPC
  APPC Type:Sync VerbID:00078000
  APPC
  APPC ---- Verb Parameter Block at address 0EF4BABC ----
  APPC 14000000 00000000 00000000 43535455 [............CSTU]
  APPC 524C4134 00000000 409B2400 D7D9E3D7 [RLA4....@.$.PRTP]
  APPC E3C8D9E4 40404040 40404040 40404040 [THRU@@@@@@@@@@@@]
  APPC 40404040 40404040 40404040 40404040 [@@@@@@@@@@@@@@@@]
  APPC 40404040 40404040 40404040 40404040 [@@@@@@@@@@@@@@@@[
  APPC 40404040 40404040 40404040 [@@@@@@@@@@@@ ]

Additional query words:

======================================================================
Keywords          :  
Technology        : kbAudDeveloper kbSNAServSearch kbSNAServ400SP3
Version           : WINDOWS:4.0 SP3
Issue type        : kbbug
Solution Type     : kbnofix

=============================================================================

{% endraw %}