layout | title | permalink |
---|---|---|
page |
Q189426: Runtime Error 1225 When Return Value Is a Recordset |
/kb/189/Q189426/ |
{% raw %}
Article: Q189426
Product(s): Microsoft SNA Server
Version(s): WINDOWS:1.0,4.0
Operating System(s):
Keyword(s):
Last Modified: 07-APR-2000
-------------------------------------------------------------------------------
The information in this article applies to:
- Microsoft COM Transaction Integrator for CICS and IMS, version 1.0, used with:
- Microsoft SNA Server, version 4.0
-------------------------------------------------------------------------------
SYMPTOMS
========
This problem occurs when you are using a CICS (non-link) Remote Environment. It
occurs under the following circumstances:
1. A COMTI method is declared where the return value is an ADO recordset.
2. In the Advanced properties of the method, the return value is
repositioned, that is, away from the default position, which is <Return value
is first item in declaration>. In COBOL terms, this means that the return
value is a data item that is NOT first in the set of items in the COBOL
declaration.
When the method is invoked, runtime error 1225 is indicated:
"COM Transaction Integrator did not receive a data-complete indication from
the Remote Environment following the expected reply data. Contact the host
application programmer. If no changes were made to the host server program
that had been operating correctly, contact Microsoft customer support."
The mainframe program sends the correct amount of data in the LU6.2 message and
the SNA Server "End Bracket" indicator is set properly.
CAUSE
=====
COMTI does not correctly handle methods in which the return value is not
positioned first in the set of COBOL declarations. It always processes the
return value first, regardless. Thus, the ODO parameter that the return value is
dependent upon is not available at the time the parameter is referenced, causing
the above test to fail.
STATUS
======
Microsoft has confirmed this to be a problem in COM Transaction Integrator for
CICS and IMS version 1.0.
Additional query words:
======================================================================
Keywords :
Technology : kbAudDeveloper kbCOMTISearch
Version : WINDOWS:1.0,4.0
Issue type : kbbug
Solution Type : kbnofix
=============================================================================
{% endraw %}