forked from multifunkim/best-brainstorm
-
Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathCHANGELOG
129 lines (106 loc) · 6.22 KB
/
CHANGELOG
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
% 26 - 10 - 2023
- MEM : Merge pipeline for EEG/MEG and fNIRS
- cMEM: Include option for depth-weighting
- MEM: add progress bar
- Baseline: better select baseline when selecting external baseline
% 22 - 04 - 2021
- All addpath were removed
- process_inverse_mem:
- Remove unused options
- be_main_call; be_check_timedef; panel_brainentropy:
- Baseline file is better handled, the panel no longer preloads it but point to its full path
- panel_brainentropy; be_main:
- Files transfered from the Brainstorm repository
% 17 - 04 - 2021
- be_gen_paths:
- Fix addpath, should add [./brainentropy] instead of [./brainentropy/best/misc]
- be_minimize_free_energy:
- Add option to use minFunc without MEX files
- panel_brainentropy:
- Add option to load a baseline file from the current Brainstorm protocol using a substring
- Add option to use minFunc without MEX files
- Remove option for loading emptyroom data
% 19 - 06 - 2019
- be_main_call: Fix opening of MATLAB parallel pool
- process_inverse_mem: Suppress warning 'eval(macro_method);'
% 25 - 07 - 2017
- launch from the 2016 SOURCE PANEL is now operational
% 08 - 09 - 2015
- cMEM EEG/MEG fusion is now operational
% 05 - 12 - 2014
- be_install : automatic update added
% 27 - 10 - 2014 : Changes requested by Francois
- panel_brainentropy : remove use of caller stack
- process_inverse_mem : change position in menu liste from 325 to 328 (after the separator)
change the process name to "Compute sources: BEst"
% 10 - 10 - 2014 : New version of the packge
- be_pipelineoptions : permute DEF and OPT in the call to be_struct_copy_fields
- be_main : be_main reserved for plugin, replaced by be_main_call
% 18 - 09 - 2014
- be_check_caller : bug correction - now brainstorm mode is set if any caller is a fcn within BrainstormHomeDir
- be_check_timedef : bug correction - OPTIONS.optional.minW replaced by minW
- be_look_for_brainentropy : added a line to move the MEM process to the right spot in brainstorm
% 03 - 09 - 2014
- process_inverse_mem : creation
- be_main : detect if called from installation or not
(avoid infinite loop)
% 11 - 08 - 2014
- be_ridgefilter : fix bug when called in standalone - select the right channels
% 09 - 08 - 2014
- panel_brainentropy : fix bug when multiple files are selected - doesnt look for default baseline
: fix bug when the field OPTIONS.mandatory.version is missing
% 06 - 08 - 2014
- be_cwavelet : fix bug when no signal padding is necessary - unset variable
- be_cwsparse : fix bug when no signal padding is necessary - unset variable
% 29 - 07 - 2014
- be_main : fix bug on stand alone version: field MSP_min_window had no default value
% 28 - 05 - 2014
- panel_brainentropy : limit panel size at first instance
- panel_brainentropy : avoid deprecated java calls warnings
- be_cwavelet : replace built-in padarray.m
- be_cwsparse : replace built-in padarray.m
- be_bpfilter : check if sig proc toolbox is installed. If not, filter with bst functions
% 26 - 05 - 2014
- panel_brainentropy : fixed bug with rMEM selection
- be_look_for_wavelab : no more automatic download - print instructions for manual download
- be_check_timedef : add the FLAG output argument
% 24 - 05 - 2014
- panel_brainentropy : restrict selection range to [4 5] for wMEM noisecov method
- panel_brainentropy : restrict selection range to [1 4] for cMEM noisecov method
- panel_brainentropy : restrict selection range to [1 5] for rMEM noisecov method
- panel_brainentropy : emptyroom option only available when expert mode is on
- panel_brainentropy : fix bug with frequency range definition in rMEM
- panel_brainentropy : show references at first panel instance
- be_wMEM_PIPELINEOPTIONS : changed default noise cov method for wMEM to 5
- be_main : new label in TF files indicating to use be_vizr.m to display
- be_main : set default display to 0
- be_vizr : text now appears in white
- be_cmem_solver : comment of the result file now has prefix cMEM
- be_rmem_solver : comment of the result file now has prefix rMEM
% 20 - 03 -2014
- be_look_for_wavelab : corrected small bug, did not add the correct
folder to matlab paths (line 40)
- be_wmem_pipelineoptions : ajout de l'option par defaut DEF.solver.NoiseCov_method
afin d'initialiser la matrice de covariance
des donnees avec l'echelle 1 des coefficients
temps-echelle
- panel_brainentropy : correction du champ scales du pipeline wMEM
ne perd plus seon contenu lorsqu'on switch en
mode expert
% 13 - 03 - 2014
- be_selected_coeffs : remplacer ''(OPTIONS.automatic.selected_samples(6,:)-1)/fs''
par ''(OPTIONS.automatic.selected_samples (2,:)-1)fs/2'' (lignes 117 et 118)''
J-M please double-check
- panel_brainentropy : ajout de l'option emptyroom
% 07 - 03 - 2014
- be_wavelet_inverse.m : remplacer "iwt_po" par "IWT_PO" (ligne 48)
- be_discrete_wavelet_transform : remplacer "fwt_po" par "FWT_PO" (ligne 44)
- be_struct_copy_fields : ajouter le champ "varargin" dans l'appel à
la fonction "be_struct_copy_fields". Ceci
permet de spécifier si les options choisies
dans l'appel à la fonction doivent "override"
les options par défaut (ce qui n'était pas
le cas avant)
- be_pipelineoptions : changer l'appel "be_struct_copyfields()" en
ajoutant le paramètre 1 à la fin (override)
(ligne 23)