Skip to content

Commit

Permalink
docs: add v2018.1.1 release notes
Browse files Browse the repository at this point in the history
  • Loading branch information
neocturne committed Aug 26, 2018
1 parent bc0d240 commit ed3cb1f
Show file tree
Hide file tree
Showing 2 changed files with 55 additions and 0 deletions.
1 change: 1 addition & 0 deletions docs/index.rst
Original file line number Diff line number Diff line change
Expand Up @@ -70,6 +70,7 @@ Several Freifunk communities in Germany use Gluon as the foundation of their Fre
:caption: Releases
:maxdepth: 1

releases/v2018.1.1
releases/v2018.1
releases/v2017.1.8
releases/v2017.1.7
Expand Down
54 changes: 54 additions & 0 deletions docs/releases/v2018.1.1.rst
Original file line number Diff line number Diff line change
@@ -0,0 +1,54 @@
Gluon 2018.1.1
==============

Bugfixes
~~~~~~~~

* Fix a bug leading to configuration loss on upgrade under certain circumstances
(`#1496 <https://github.com/freifunk-gluon/gluon/issues/1496>`_)

The issue can only occur when upgrading from 2018.1 and there are multiple
mirror entries in *site.conf* (specifically, an early failure for one of the
mirrors, e.g. during DNS resolution, followed by a successful upgrade from a
different mirror triggers the issue).

This is a regression in Gluon 2018.1.

* Fix next-node ARP issue
(`#1488 <https://github.com/freifunk-gluon/gluon/issues/1488>`_)

A routing table issue led to ARP requests being sent from the next-node IPv4 address, but with
a node-specific source MAC address. This could make the next-node IPv4 address unreachable.

This is a regression in Gluon 2018.1.

* Fix build on hosts with glibc 2.28

Fixed by various tool upgrades in LEDE (*bison*, *e2fsutils*, ...)

Other changes
~~~~~~~~~~~~~

* Linux kernel has been updated to v4.4.148

Known issues
~~~~~~~~~~~~

* Default TX power on many Ubiquiti devices is too high, correct offsets are unknown (`#94 <https://github.com/freifunk-gluon/gluon/issues/94>`_)

Reducing the TX power in the Advanced Settings is recommended.

* The MAC address of the WAN interface is modified even when Mesh-on-WAN is disabled (`#496 <https://github.com/freifunk-gluon/gluon/issues/496>`_)

This may lead to issues in environments where a fixed MAC address is expected (like VMware when promicious mode is disallowed).

* Inconsistent respondd API (`#522 <https://github.com/freifunk-gluon/gluon/issues/522>`_)

The current API is inconsistent and will be replaced eventually. The old API will still be supported for a while.

* Frequent reboots due to out-of-memory or high load due to memory pressure on weak hardware specially in larger meshes
(`#1243 <https://github.com/freifunk-gluon/gluon/issues/1243>`_)

Optimizations in Gluon 2018.1 have significantly improved memory usage.
There are still known bugs leading to unreasonably high load that we hope to
solve in future releases.

0 comments on commit ed3cb1f

Please sign in to comment.