controlling Tesla charging with callbox gen 3
network: schema: http host: *** port: *** database: type: sqlite dsn: *** sponsortoken: *** log: debug levels: cache: error plant: *** interval: *** modbusproxy: - port: *** uri: *** meters: - type: template template: alpha-ess-smile id: *** host: *** port: *** usage: *** modbus: *** name: *** - type: template template: alpha-ess-smile id: *** host: *** port: *** usage: *** modbus: *** name: *** - type: template template: alpha-ess-smile id: *** host: *** port: *** usage: *** modbus: *** name: *** chargers: - name: *** type: template template: twc3 host: *** loadpoints: - title: *** charger: *** mode: *** phases: *** mincurrent: *** maxcurrent: *** guardduration: *** vehicle: *** site: title: *** meters: grid: *** pv: - *** battery: - *** residualPower: *** vehicles: - name: *** type: template template: tesla title: *** accessToken: *** refreshToken: ***
[lp-1 ] ERROR 2024/07/09 20:30:37 charger disable: Post "https://tesla.evcc.io/api/1/vehicles/***/command/charge_stop": net/http: request canceled (Client.Timeout exceeded while awaiting headers) [site ] DEBUG 2024/07/09 20:30:37 ---- [lp-1 ] DEBUG 2024/07/09 20:30:37 charge power: 5687W [lp-1 ] DEBUG 2024/07/09 20:30:37 charge currents: [8.1 8.1 8.1]A [site ] DEBUG 2024/07/09 20:30:37 pv power: 0W [site ] DEBUG 2024/07/09 20:30:37 battery soc: 78% [site ] DEBUG 2024/07/09 20:30:37 battery power: 6553W [site ] DEBUG 2024/07/09 20:30:37 grid meter: 48W [site ] DEBUG 2024/07/09 20:30:37 grid currents: [1.5 2 -1.6]A [site ] DEBUG 2024/07/09 20:30:37 site power: 6801W [lp-1 ] DEBUG 2024/07/09 20:30:37 charge voltages: [235 233 234]V [lp-1 ] DEBUG 2024/07/09 20:30:37 detected connected phases: 3p [lp-1 ] DEBUG 2024/07/09 20:30:37 detected active phases: 3p [lp-1 ] DEBUG 2024/07/09 20:30:37 !! session: chargeRater.chargedEnergy=0.2 - chargedAtStartup=0.0 [lp-1 ] DEBUG 2024/07/09 20:30:37 charger status: C [lp-1 ] DEBUG 2024/07/09 20:30:37 vehicle soc: 76% [lp-1 ] DEBUG 2024/07/09 20:30:37 vehicle soc limit: 69% [lp-1 ] DEBUG 2024/07/09 20:30:37 vehicle range: 337km [lp-1 ] ERROR 2024/07/09 20:30:47 charger disable: Post "https://tesla.evcc.io/api/1/vehicles/***/command/charge_stop": net/http: request canceled (Client.Timeout exceeded while awaiting headers) [site ] DEBUG 2024/07/09 20:30:47 ---- [lp-1 ] DEBUG 2024/07/09 20:30:47 charge power: 0W [lp-1 ] DEBUG 2024/07/09 20:30:47 charge currents: [0.2 0.4 0.3]A [site ] DEBUG 2024/07/09 20:30:47 pv power: 0W [site ] DEBUG 2024/07/09 20:30:47 battery soc: 78% [site ] DEBUG 2024/07/09 20:30:47 battery power: 5108W [site ] DEBUG 2024/07/09 20:30:47 grid meter: -4185W [site ] DEBUG 2024/07/09 20:30:47 grid currents: [-5.6 -5.7 -6.8]A [site ] DEBUG 2024/07/09 20:30:47 site power: 1123W [lp-1 ] DEBUG 2024/07/09 20:30:47 charge voltages: [7 0 0]V [lp-1 ] DEBUG 2024/07/09 20:30:47 !! session: chargeRater.chargedEnergy=0.2 - chargedAtStartup=0.0 [lp-1 ] DEBUG 2024/07/09 20:30:47 charger status: B [lp-1 ] INFO 2024/07/09 20:30:47 stop charging <- [lp-1 ] DEBUG 2024/07/09 20:30:47 wake-up timer: start [lp-1 ] DEBUG 2024/07/09 20:30:47 !! session: chargedEnergy=0.2 > chargedEnergy=0.0 [lp-1 ] DEBUG 2024/07/09 20:30:47 !! session: start=0.000 stop=0.000 chargedEnergy=0.200 [lp-1 ] DEBUG 2024/07/09 20:30:48 vehicle soc: 76% [lp-1 ] DEBUG 2024/07/09 20:30:48 vehicle soc limit: 69% [lp-1 ] DEBUG 2024/07/09 20:30:48 vehicle range: 337km [lp-1 ] WARN 2024/07/09 20:30:48 charger out of sync: expected enabled, got disabled [lp-1 ] DEBUG 2024/07/09 20:30:48 charger disable
Linux
0.128.1
The text was updated successfully, but these errors were encountered:
Duplicate #14226
Sorry, something went wrong.
sorry for not looking in the existing issues :(
No branches or pull requests
Describe the bug
Steps to reproduce
controlling Tesla charging with callbox gen 3
Configuration details
Log details
What type of operating system are you running?
Linux
Version
0.128.1