SPC Timer resets after 476 seconds #70

Closed
Argonfunk opened this issue Dec 6, 2024 · 1 comment
Closed

SPC Timer resets after 476 seconds #70

Argonfunk opened this issue Dec 6, 2024 · 1 comment
Assignees
Labels
bug Something isn't working fixed This issue was fixed, waiting for stable release

Comments

@Argonfunk
Copy link

Rendered with SPCPlay v2.20.5 (build 8581) on Windows 10
https://github.com/user-attachments/assets/839b5548-c134-427a-88b7-8a1d96461c24

Whenever an item reaches 7:56 (476 seconds) on playback, the SPC Timer is reset to draw from the very beginning which is an inaccurate visualization since the fadeout timer and playback timers are counted for properly. This occurs with every SPC file across several different sound drivers that are longer than 476 seconds on ID666 Time.

@dgrfactory dgrfactory self-assigned this Dec 13, 2024
@dgrfactory
Copy link
Owner

Hi, @Argonfunk
Thank you for reporting the issue.

This issue has been fixed in the following release:
https://github.com/dgrfactory/spcplay/releases/tag/2.20.6.8652b
An overflow occurred during the numerical calculation because variable is 32-bit, so it has been expanded to 64-bit.

@dgrfactory dgrfactory added bug Something isn't working fixed This issue was fixed, waiting for stable release labels Dec 13, 2024
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
bug Something isn't working fixed This issue was fixed, waiting for stable release
Projects
None yet
Development

No branches or pull requests

2 participants