Skip to content

Latest commit

 

History

History
90 lines (63 loc) · 2.49 KB

Server-API.md

File metadata and controls

90 lines (63 loc) · 2.49 KB

OCPP.Core Server API

Most messages are initiated by the chargers. But some messages are initiated by the OCPP backend. OCPP.Core currently supports:

  • Reset
  • UnlockConnector
  • SetChargingProfile (not verified)
  • ClearChargingProfile (not verified)

The OCPP.Core.Server offers an API for using these messages. Additionally the server supports a status request for the online status of all connected chargers. The management UI uses this API as well.

API format

The REST-API uses the following format:

/API/<command>[/chargepointId[/connectorId[/parameter]]]

For authentication/authorization purposes the API uses an API-key (like a password). This key must be send as an http header "X-API-Key" - see here. The allowed key is configured in the appsettings.json.

Functions

Status

Request the status of all connected chargers and connectors

/API/Status

The answer should be (example): [ { "id": "station42", "name": "myWallbox", "protocol": "ocpp1.6", "OnlineConnectors": { "1": { "Status": 1, "ChargeRateKW": null, "MeterKWH": null, "SoC": null } } } ]

Reset

Initiates a reset/reboot of the charger.

/API/Reset/station42

The answer should be: {"status"="Accepted"} or {"status"="Rejected"} or with OCPP 2.x {"status"="Scheduled"}

UnlockConnector

Send an unlock request for a certain connector

/API/UnlockConnector/station42/1

The answer should be: {"status"="Unlocked"} or {"status"="UnlockFailed"} or
OCPP1.6 {"status"="NotSupported"} OCPP2.x {"status"="OngoingAuthorizedTransaction"} or {"status"="UnknownConnector"}

SetChargingProfile

Sets a charging limit (power) for a certain connector. OCPP.Core does not support schedules. It sets the specified limit as a simple daily 24h schedule (=constant limit).

/API/SetChargingLimit/station42/1/2000W 

or

/API/SetChargingLimit/station42/1/16A

The answer should be: {"status"="Accepted"} or {"status"="Rejected"} or OCPP1.6 {"status"="NotSupported"}

Comment: Our Keba chargers are rejecting limits for specific connectors. But they accept connectorId=0 as the setting for all connectors.

ClearChargingProfile

Clears the charging limit (power) for a certain connector.

/API/ClearChargingLimit/station42/1"