-
Notifications
You must be signed in to change notification settings - Fork 0
/
dracut-module-setup.sh
executable file
·1075 lines (883 loc) · 32.3 KB
/
dracut-module-setup.sh
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
#!/bin/bash
_DRACUT_KDUMP_NM_TMP_DIR="$DRACUT_TMPDIR/$$-DRACUT_KDUMP_NM"
_save_kdump_netifs() {
unique_netifs[$1]=1
}
_get_kdump_netifs() {
echo -n "${!unique_netifs[@]}"
}
kdump_module_init() {
# shellcheck disable=SC2154 # $initdir is a dracut variable
if ! [[ -d "${initdir}/tmp" ]]; then
mkdir -p "${initdir}/tmp"
fi
mkdir -p "$_DRACUT_KDUMP_NM_TMP_DIR"
. /lib/kdump/kdump-lib.sh
}
check() {
# shellcheck disable=SC2154 # $debug is a dracut variable
[[ $debug ]] && set -x
#kdumpctl sets this explicitly
if [[ -z $IN_KDUMP ]] || [[ ! -f /etc/kdump.conf ]]; then
return 1
fi
return 0
}
depends() {
local _dep="base shutdown"
kdump_module_init
add_opt_module() {
# shellcheck disable=SC2154 # $omit_dracutmodules is a dracut variable
[[ " $omit_dracutmodules " != *\ $1\ * ]] && _dep="$_dep $1"
}
if is_squash_available; then
add_opt_module squash
else
dwarning "Required modules to build a squashed kdump image is missing!"
fi
if is_wdt_active; then
add_opt_module watchdog
fi
if is_ssh_dump_target; then
_dep="$_dep ssh-client"
fi
if is_lvm2_thinp_dump_target; then
if dracut --list-modules | grep -q lvmthinpool-monitor; then
add_opt_module lvmthinpool-monitor
else
dwarning "Required lvmthinpool-monitor modules is missing! Please upgrade dracut >= 057."
fi
fi
if [[ "$(uname -m)" == "s390x" ]]; then
_dep="$_dep znet"
fi
if [[ -n "$(ls -A /sys/class/drm 2> /dev/null)" ]] || [[ -d /sys/module/hyperv_fb ]]; then
add_opt_module drm
fi
if is_generic_fence_kdump || is_pcs_fence_kdump; then
_dep="$_dep network"
fi
echo "$_dep"
}
kdump_is_bridge() {
[[ -d /sys/class/net/"$1"/bridge ]]
}
kdump_is_bond() {
[[ -d /sys/class/net/"$1"/bonding ]]
}
kdump_is_team() {
[[ -f /usr/bin/teamnl ]] && teamnl "$1" ports &> /dev/null
}
kdump_is_vlan() {
[[ -f /proc/net/vlan/"$1" ]]
}
# $1: repeat times
# $2: string to be repeated
# $3: separator
repeatedly_join_str() {
local _count="$1"
local _str="$2"
local _separator="$3"
local i _res
if [[ $_count -le 0 ]]; then
echo -n ""
return
fi
i=0
_res="$_str"
((_count--))
while [[ $i -lt $_count ]]; do
((i++))
_res="${_res}${_separator}${_str}"
done
echo -n "$_res"
}
# $1: prefix
# $2: ipv6_flag="-6" indicates it's IPv6
# Given a prefix, calculate the netmask (equivalent of "ipcalc -m")
# by concatenating three parts,
# 1) the groups with all bits set 1
# 2) a group with partial bits set to 0
# 3) the groups with all bits set to 0
cal_netmask_by_prefix() {
local _prefix="$1"
local _ipv6_flag="$2" _ipv6
local _bits_per_octet=8
local _count _res _octets_per_group _octets_total _seperator _total_groups
local _max_group_value _max_group_value_repr _bits_per_group _tmp _zero_bits
if [[ $_ipv6_flag == "-6" ]]; then
_ipv6=1
else
_ipv6=0
fi
if [[ $_prefix -lt 0 || $_prefix -gt 128 ]] \
|| ( ((!_ipv6)) && [[ $_prefix -gt 32 ]]); then
derror "Bad prefix:$_prefix for calculating netmask"
exit 1
fi
if ((_ipv6)); then
_octets_per_group=2
_octets_total=16
_seperator=":"
else
_octets_per_group=1
_octets_total=4
_seperator="."
fi
_total_groups=$((_octets_total / _octets_per_group))
_bits_per_group=$((_octets_per_group * _bits_per_octet))
_max_group_value=$(((1 << _bits_per_group) - 1))
if ((_ipv6)); then
_max_group_value_repr=$(printf "%x" $_max_group_value)
else
_max_group_value_repr="$_max_group_value"
fi
_count=$((_prefix / _octets_per_group / _bits_per_octet))
_first_part=$(repeatedly_join_str "$_count" "$_max_group_value_repr" "$_seperator")
_res="$_first_part"
_tmp=$((_octets_total * _bits_per_octet - _prefix))
_zero_bits=$((_tmp % _bits_per_group))
if [[ $_zero_bits -ne 0 ]]; then
_second_part=$((_max_group_value >> _zero_bits << _zero_bits))
if ((_ipv6)); then
_second_part=$(printf "%x" $_second_part)
fi
((_count++))
if [[ -z $_first_part ]]; then
_res="$_second_part"
else
_res="${_first_part}${_seperator}${_second_part}"
fi
fi
_count=$((_total_groups - _count))
if [[ $_count -eq 0 ]]; then
echo -n "$_res"
return
fi
if ((_ipv6)) && [[ $_count -gt 1 ]]; then
# use condensed notion for IPv6
_third_part=":"
else
_third_part=$(repeatedly_join_str "$_count" "0" "$_seperator")
fi
if [[ -z $_res ]] && ((!_ipv6)); then
echo -n "${_third_part}"
else
echo -n "${_res}${_seperator}${_third_part}"
fi
}
kdump_get_mac_addr() {
cat "/sys/class/net/$1/address"
}
#Bonding or team master modifies the mac address
#of its slaves, we should use perm address
kdump_get_perm_addr() {
local addr
addr=$(ethtool -P "$1" | sed -e 's/Permanent address: //')
if [[ -z $addr ]] || [[ $addr == "00:00:00:00:00:00" ]]; then
derror "Can't get the permanent address of $1"
else
echo "$addr"
fi
}
apply_nm_initrd_generator_timeouts() {
local _timeout_conf
_timeout_conf=$_DRACUT_KDUMP_NM_TMP_DIR/timeout_conf
cat << EOF > "$_timeout_conf"
[device-95-kdump]
carrier-wait-timeout=30000
[connection-95-kdump]
ipv4.dhcp-timeout=90
ipv6.dhcp-timeout=90
EOF
inst "$_timeout_conf" "/etc/NetworkManager/conf.d/95-kdump-timeouts.conf"
}
use_ipv4_or_ipv6() {
local _netif=$1 _uuid=$2
if [[ -v "ipv4_usage[$_netif]" ]]; then
nmcli connection modify --temporary "$_uuid" ipv4.may-fail no &> >(ddebug)
fi
if [[ -v "ipv6_usage[$_netif]" ]]; then
nmcli connection modify --temporary "$_uuid" ipv6.may-fail no &> >(ddebug)
fi
if [[ -v "ipv4_usage[$_netif]" ]] && [[ ! -v "ipv6_usage[$_netif]" ]]; then
nmcli connection modify --temporary "$_uuid" ipv6.method disabled &> >(ddebug)
elif [[ ! -v "ipv4_usage[$_netif]" ]] && [[ -v "ipv6_usage[$_netif]" ]]; then
nmcli connection modify --temporary "$_uuid" ipv4.method disabled &> >(ddebug)
fi
}
_clone_nmconnection() {
local _clone_output _name _unique_id
_unique_id=$1
_name=$(nmcli --get-values connection.id connection show "$_unique_id")
if _clone_output=$(nmcli connection clone --temporary uuid "$_unique_id" "$_name"); then
sed -E -n "s/.* \(.*\) cloned as.*\((.*)\)\.$/\1/p" <<< "$_clone_output"
return 0
fi
return 1
}
_match_nmconnection_by_mac() {
local _unique_id _dev _mac _mac_field
_unique_id=$1
_dev=$2
_mac=$(kdump_get_perm_addr "$_dev")
[[ $_mac != 'not set' ]] || return
_mac_field=$(nmcli --get-values connection.type connection show "$_unique_id").mac-address
nmcli connection modify --temporary "$_unique_id" "$_mac_field" "$_mac" &> >(ddebug)
nmcli connection modify --temporary "$_unique_id" "connection.interface-name" "" &> >(ddebug)
}
# Clone and modify NM connection profiles
#
# This function makes use of "nmcli clone" to automatically convert ifcfg-*
# files to Networkmanager .nmconnection connection profiles and also modify the
# properties of .nmconnection if necessary.
clone_and_modify_nmconnection() {
local _dev _cloned_nmconnection_file_path _tmp_nmconnection_file_path _old_uuid _uuid
_dev=$1
_nmconnection_file_path=$2
_old_uuid=$(nmcli --get-values connection.uuid connection show filename "$_nmconnection_file_path")
if ! _uuid=$(_clone_nmconnection "$_old_uuid"); then
derror "Failed to clone $_old_uuid"
exit 1
fi
use_ipv4_or_ipv6 "$_dev" "$_uuid"
nmcli connection modify --temporary uuid "$_uuid" connection.wait-device-timeout 60000 &> >(ddebug)
# For physical NIC i.e. non-user created NIC, ask NM to match a
# connection profile based on MAC address
_match_nmconnection_by_mac "$_uuid" "$_dev"
# If a value contain ":", nmcli by default escape it with "\:" because it
# also uses ":" as the delimiter to separate values. In our case, escaping is not needed.
_cloned_nmconnection_file_path=$(nmcli --escape no --get-values UUID,FILENAME connection show | sed -n "s/^${_uuid}://p")
_tmp_nmconnection_file_path=$_DRACUT_KDUMP_NM_TMP_DIR/$(basename "$_nmconnection_file_path")
cp "$_cloned_nmconnection_file_path" "$_tmp_nmconnection_file_path"
# change uuid back to old value in case it's refered by other connection
# profile e.g. connection.master could be interface name of the master
# device or UUID of the master connection.
sed -i -E "s/(^uuid=).*$/\1${_old_uuid}/g" "$_tmp_nmconnection_file_path"
nmcli connection del "$_uuid" &> >(ddebug)
echo -n "$_tmp_nmconnection_file_path"
}
_install_nmconnection() {
local _src _nmconnection_name _dst
_src=$1
_nmconnection_name=$(basename "$_src")
_dst="/etc/NetworkManager/system-connections/$_nmconnection_name"
inst "$_src" "$_dst"
}
kdump_install_nmconnections() {
local _netif _nm_conn_path _cloned_nm_path
while IFS=: read -r _netif _nm_conn_path; do
[[ -v "unique_netifs[$_netif]" ]] || continue
if _cloned_nm_path=$(clone_and_modify_nmconnection "$_netif" "$_nm_conn_path"); then
_install_nmconnection "$_cloned_nm_path"
else
derror "Failed to install the .nmconnection for $_netif"
exit 1
fi
done <<< "$(nmcli -t -f device,filename connection show --active)"
# Stop dracut 35network-manger to calling nm-initrd-generator.
# Note this line of code can be removed after NetworkManager >= 1.35.2
# gets released.
echo > "${initdir}/usr/libexec/nm-initrd-generator"
}
kdump_install_nm_netif_allowlist() {
local _netif _except_netif _netif_allowlist _netif_allowlist_nm_conf
for _netif in $1; do
_per_mac=$(kdump_get_perm_addr "$_netif")
if [[ "$_per_mac" != 'not set' ]]; then
_except_netif="mac:$_per_mac"
else
_except_netif="interface-name:$_netif"
fi
_netif_allowlist="${_netif_allowlist}except:${_except_netif};"
done
_netif_allowlist_nm_conf=$_DRACUT_KDUMP_NM_TMP_DIR/netif_allowlist_nm_conf
cat << EOF > "$_netif_allowlist_nm_conf"
[device-others]
match-device=${_netif_allowlist}
managed=false
EOF
inst "$_netif_allowlist_nm_conf" "/etc/NetworkManager/conf.d/10-kdump-netif_allowlist.conf"
}
_get_nic_driver() {
ethtool -i "$1" | sed -n -E "s/driver: (.*)/\1/p"
}
_get_hpyerv_physical_driver() {
local _physical_nic
_physical_nic=$(find /sys/class/net/"$1"/ -name 'lower_*' | sed -En "s/\/.*lower_(.*)/\1/p")
[[ -n $_physical_nic ]] || return
_get_nic_driver "$_physical_nic"
}
kdump_install_nic_driver() {
local _netif _driver _drivers
_drivers=()
for _netif in $1; do
[[ $_netif == lo ]] && continue
_driver=$(_get_nic_driver "$_netif")
if [[ -z $_driver ]]; then
derror "Failed to get the driver of $_netif"
exit 1
fi
if [[ $_driver == "802.1Q VLAN Support" ]]; then
# ethtool somehow doesn't return the driver name for a VLAN NIC
_driver=8021q
elif [[ $_driver == "team" ]]; then
# install the team mode drivers like team_mode_roundrobin.ko as well
_driver='=drivers/net/team'
elif [[ $_driver == "hv_netvsc" ]]; then
# A Hyper-V VM may have accelerated networking
# https://learn.microsoft.com/en-us/azure/virtual-network/accelerated-networking-overview
# Install the driver of physical NIC as well
_drivers+=("$(_get_hpyerv_physical_driver "$_netif")")
fi
_drivers+=("$_driver")
done
[[ -n ${_drivers[*]} ]] || return
instmods "${_drivers[@]}"
}
kdump_setup_bridge() {
local _netdev=$1
local _dev
for _dev in "/sys/class/net/$_netdev/brif/"*; do
[[ -e $_dev ]] || continue
_dev=${_dev##*/}
if kdump_is_bond "$_dev"; then
kdump_setup_bond "$_dev" || return 1
elif kdump_is_team "$_dev"; then
kdump_setup_team "$_dev"
elif kdump_is_vlan "$_dev"; then
kdump_setup_vlan "$_dev"
fi
_save_kdump_netifs "$_dev"
done
}
kdump_setup_bond() {
local _netdev="$1"
local _dev
for _dev in $(< "/sys/class/net/$_netdev/bonding/slaves"); do
_save_kdump_netifs "$_dev"
done
}
kdump_setup_team() {
local _netdev=$1
local _dev
for _dev in $(teamnl "$_netdev" ports | awk -F':' '{print $2}'); do
_save_kdump_netifs "$_dev"
done
}
kdump_setup_vlan() {
local _netdev=$1
local _parent_netif
_parent_netif="$(awk '/^Device:/{print $2}' /proc/net/vlan/"$_netdev")"
#Just support vlan over bond and team
if kdump_is_bridge "$_parent_netif"; then
derror "Vlan over bridge is not supported!"
exit 1
elif kdump_is_bond "$_parent_netif"; then
kdump_setup_bond "$_parent_netif" || return 1
elif kdump_is_team "$_parent_netif"; then
kdump_setup_team "$_parent_netif" || return 1
fi
_save_kdump_netifs "$_parent_netif"
}
_find_znet_nmconnection() {
LANG=C grep -s -E -i -l \
"^s390-subchannels=([0-9]\.[0-9]\.[a-f0-9]+;){0,2}" \
"$1"/*.nmconnection | LC_ALL=C sed -e "$2"
}
# setup s390 znet
#
# Note part of code is extracted from ccw_init provided by s390utils
kdump_setup_znet() {
local _config_file _unique_name _NM_conf_dir
local __sed_discard_ignored_files='/\(~\|\.bak\|\.old\|\.orig\|\.rpmnew\|\.rpmorig\|\.rpmsave\)$/d'
if [[ "$(uname -m)" != "s390x" ]]; then
return
fi
_NM_conf_dir="/etc/NetworkManager/system-connections"
_config_file=$(_find_znet_nmconnection "$initdir/$_NM_conf_dir" "$__sed_discard_ignored_files")
if [[ -n "$_config_file" ]]; then
ddebug "$_config_file has already contained the znet config"
return
fi
_config_file=$(LANG=C grep -s -E -i -l \
"^[[:space:]]*SUBCHANNELS=['\"]?([0-9]\.[0-9]\.[a-f0-9]+,){0,2}" \
/etc/sysconfig/network-scripts/ifcfg-* \
| LC_ALL=C sed -e "$__sed_discard_ignored_files")
if [[ -z "$_config_file" ]]; then
_config_file=$(_find_znet_nmconnection "$_NM_conf_dir" "$__sed_discard_ignored_files")
fi
if [[ -n "$_config_file" ]]; then
_unique_name=$(cat /proc/sys/kernel/random/uuid)
nmcli connection clone --temporary "$_config_file" "$_unique_name" &> >(ddebug)
nmcli connection modify --temporary "$_unique_name" connection.autoconnect false
inst "/run/NetworkManager/system-connections/${_unique_name}.nmconnection" "${_NM_conf_dir}/${_unique_name}.nmconnection"
nmcli connection del "$_unique_name" &> >(ddebug)
fi
}
kdump_get_remote_ip() {
local _remote _remote_temp
_remote=$(get_remote_host "$1")
if is_hostname "$_remote"; then
_remote_temp=$(getent ahosts "$_remote" | grep -v : | head -n 1)
if [[ -z $_remote_temp ]]; then
_remote_temp=$(getent ahosts "$_remote" | head -n 1)
fi
_remote=$(echo "$_remote_temp" | awk '{print $1}')
fi
echo "$_remote"
}
# Collect netifs needed by kdump
# $1: destination host
kdump_collect_netif_usage() {
local _destaddr _srcaddr _route _netdev
_destaddr=$(kdump_get_remote_ip "$1")
if ! _route=$(kdump_get_ip_route "$_destaddr"); then
derror "Bad kdump network destination: $_destaddr"
exit 1
fi
_srcaddr=$(kdump_get_ip_route_field "$_route" "src")
_netdev=$(kdump_get_ip_route_field "$_route" "dev")
if kdump_is_bridge "$_netdev"; then
kdump_setup_bridge "$_netdev"
elif kdump_is_bond "$_netdev"; then
kdump_setup_bond "$_netdev" || return 1
elif kdump_is_team "$_netdev"; then
kdump_setup_team "$_netdev"
elif kdump_is_vlan "$_netdev"; then
kdump_setup_vlan "$_netdev"
fi
_save_kdump_netifs "$_netdev"
if [[ ! -f ${initdir}/etc/cmdline.d/50neednet.conf ]]; then
# network-manager module needs this parameter
echo "rd.neednet" >> "${initdir}/etc/cmdline.d/50neednet.conf"
fi
if [[ ! -f ${initdir}/etc/cmdline.d/60kdumpip.conf ]]; then
echo "kdump_remote_ip=$_destaddr" > "${initdir}/etc/cmdline.d/60kdumpip.conf"
fi
if is_ipv6_address "$_srcaddr"; then
ipv6_usage[$_netdev]=1
else
ipv4_usage[$_netdev]=1
fi
}
# Setup dracut to bring up network interface that enable
# initramfs accessing giving destination
kdump_install_net() {
local _netifs
_netifs=$(_get_kdump_netifs)
if [[ -n "$_netifs" ]]; then
kdump_install_nmconnections
apply_nm_initrd_generator_timeouts
kdump_setup_znet
kdump_install_nm_netif_allowlist "$_netifs"
kdump_install_nic_driver "$_netifs"
fi
}
# install etc/kdump/pre.d and /etc/kdump/post.d
kdump_install_pre_post_conf() {
if [[ -d /etc/kdump/pre.d ]]; then
for file in /etc/kdump/pre.d/*; do
if [[ -x $file ]]; then
dracut_install "$file"
elif [[ $file != "/etc/kdump/pre.d/*" ]]; then
echo "$file is not executable"
fi
done
fi
if [[ -d /etc/kdump/post.d ]]; then
for file in /etc/kdump/post.d/*; do
if [[ -x $file ]]; then
dracut_install "$file"
elif [[ $file != "/etc/kdump/post.d/*" ]]; then
echo "$file is not executable"
fi
done
fi
}
default_dump_target_install_conf() {
local _target _fstype
local _mntpoint _save_path
is_user_configured_dump_target && return
_save_path=$(get_bind_mount_source "$(get_save_path)")
_target=$(get_target_from_path "$_save_path")
_mntpoint=$(get_mntpoint_from_target "$_target")
_fstype=$(get_fs_type_from_target "$_target")
if is_fs_type_nfs "$_fstype"; then
kdump_collect_netif_usage "$_target"
_fstype="nfs"
else
_target=$(kdump_get_persistent_dev "$_target")
fi
echo "$_fstype $_target" >> "${initdir}/tmp/$$-kdump.conf"
# don't touch the path under root mount
if [[ $_mntpoint != "/" ]]; then
_save_path=${_save_path##"$_mntpoint"}
fi
#erase the old path line, then insert the parsed path
sed -i "/^path/d" "${initdir}/tmp/$$-kdump.conf"
echo "path $_save_path" >> "${initdir}/tmp/$$-kdump.conf"
}
#install kdump.conf and what user specifies in kdump.conf
kdump_install_conf() {
local _opt _val _pdev
kdump_read_conf > "${initdir}/tmp/$$-kdump.conf"
while read -r _opt _val; do
# remove inline comments after the end of a directive.
case "$_opt" in
raw)
_pdev=$(persistent_policy="by-id" kdump_get_persistent_dev "$_val")
sed -i -e "s#^${_opt}[[:space:]]\+$_val#$_opt $_pdev#" "${initdir}/tmp/$$-kdump.conf"
;;
ext[234] | xfs | btrfs | minix | virtiofs)
_pdev=$(kdump_get_persistent_dev "$_val")
sed -i -e "s#^${_opt}[[:space:]]\+$_val#$_opt $_pdev#" "${initdir}/tmp/$$-kdump.conf"
;;
ssh | nfs)
kdump_collect_netif_usage "$_val"
;;
dracut_args)
if [[ $(get_dracut_args_fstype "$_val") == nfs* ]]; then
kdump_collect_netif_usage "$(get_dracut_args_target "$_val")"
fi
;;
kdump_pre | kdump_post | extra_bins)
# shellcheck disable=SC2086
dracut_install $_val
;;
core_collector)
dracut_install "${_val%%[[:blank:]]*}"
;;
esac
done <<< "$(kdump_read_conf)"
kdump_install_pre_post_conf
default_dump_target_install_conf
kdump_configure_fence_kdump "${initdir}/tmp/$$-kdump.conf"
inst "${initdir}/tmp/$$-kdump.conf" "/etc/kdump.conf"
rm -f "${initdir}/tmp/$$-kdump.conf"
}
# Default sysctl parameters should suffice for kdump kernel.
# Remove custom configurations sysctl.conf & sysctl.d/*
remove_sysctl_conf() {
# As custom configurations like vm.min_free_kbytes can lead
# to OOM issues in kdump kernel, avoid them
rm -f "${initdir}/etc/sysctl.conf"
rm -rf "${initdir}/etc/sysctl.d"
rm -rf "${initdir}/run/sysctl.d"
rm -rf "${initdir}/usr/lib/sysctl.d"
}
kdump_iscsi_get_rec_val() {
local result
# The open-iscsi 742 release changed to using flat files in
# /var/lib/iscsi.
result=$(/sbin/iscsiadm --show -m session -r "$1" | grep "^${2} = ")
result=${result##* = }
echo "$result"
}
kdump_get_iscsi_initiator() {
local _initiator
local initiator_conf="/etc/iscsi/initiatorname.iscsi"
[[ -f $initiator_conf ]] || return 1
while read -r _initiator; do
[[ -z ${_initiator%%#*} ]] && continue # Skip comment lines
case $_initiator in
InitiatorName=*)
initiator=${_initiator#InitiatorName=}
echo "rd.iscsi.initiator=${initiator}"
return 0
;;
*) ;;
esac
done < ${initiator_conf}
return 1
}
# Figure out iBFT session according to session type
is_ibft() {
[[ "$(kdump_iscsi_get_rec_val "$1" "node.discovery_type")" == fw ]]
}
kdump_setup_iscsi_device() {
local path=$1
local tgt_name
local tgt_ipaddr
local username
local password
local userpwd_str
local username_in
local password_in
local userpwd_in_str
local netroot_str
local initiator_str
local netroot_conf="${initdir}/etc/cmdline.d/50iscsi.conf"
local initiator_conf="/etc/iscsi/initiatorname.iscsi"
dinfo "Found iscsi component $1"
# Check once before getting explicit values, so we can bail out early,
# e.g. in case of pure-hardware(all-offload) iscsi.
if ! /sbin/iscsiadm -m session -r "$path" &> /dev/null; then
return 1
fi
if is_ibft "$path"; then
return
fi
# Remove software iscsi cmdline generated by 95iscsi,
# and let kdump regenerate here.
rm -f "${initdir}/etc/cmdline.d/95iscsi.conf"
tgt_name=$(kdump_iscsi_get_rec_val "$path" "node.name")
tgt_ipaddr=$(kdump_iscsi_get_rec_val "$path" "node.conn\[0\].address")
# get and set username and password details
username=$(kdump_iscsi_get_rec_val "$path" "node.session.auth.username")
[[ $username == "<empty>" ]] && username=""
password=$(kdump_iscsi_get_rec_val "$path" "node.session.auth.password")
[[ $password == "<empty>" ]] && password=""
username_in=$(kdump_iscsi_get_rec_val "$path" "node.session.auth.username_in")
[[ -n $username ]] && userpwd_str="$username:$password"
# get and set incoming username and password details
[[ $username_in == "<empty>" ]] && username_in=""
password_in=$(kdump_iscsi_get_rec_val "$path" "node.session.auth.password_in")
[[ $password_in == "<empty>" ]] && password_in=""
[[ -n $username_in ]] && userpwd_in_str=":$username_in:$password_in"
kdump_collect_netif_usage "$tgt_ipaddr"
# prepare netroot= command line
# FIXME: Do we need to parse and set other parameters like protocol, port
# iscsi_iface_name, netdev_name, LUN etc.
if is_ipv6_address "$tgt_ipaddr"; then
tgt_ipaddr="[$tgt_ipaddr]"
fi
netroot_str="netroot=iscsi:${userpwd_str}${userpwd_in_str}@$tgt_ipaddr::::$tgt_name"
[[ -f $netroot_conf ]] || touch "$netroot_conf"
# If netroot target does not exist already, append.
if ! grep -q "$netroot_str" "$netroot_conf"; then
echo "$netroot_str" >> "$netroot_conf"
dinfo "Appended $netroot_str to $netroot_conf"
fi
# Setup initator
if ! initiator_str=$(kdump_get_iscsi_initiator); then
derror "Failed to get initiator name"
return 1
fi
# If initiator details do not exist already, append.
if ! grep -q "$initiator_str" "$netroot_conf"; then
echo "$initiator_str" >> "$netroot_conf"
dinfo "Appended $initiator_str to $netroot_conf"
fi
}
kdump_check_iscsi_targets() {
# If our prerequisites are not met, fail anyways.
type -P iscsistart > /dev/null || return 1
kdump_check_setup_iscsi() {
local _dev
_dev=$1
[[ -L /sys/dev/block/$_dev ]] || return
cd "$(readlink -f "/sys/dev/block/$_dev")" || return 1
until [[ -d sys || -d iscsi_session ]]; do
cd ..
done
[[ -d iscsi_session ]] && kdump_setup_iscsi_device "$PWD"
}
# shellcheck disable=SC2154 # $hostonly and $mount_needs are from dracut
[[ $hostonly ]] || [[ $mount_needs ]] && {
for_each_host_dev_and_slaves_all kdump_check_setup_iscsi
}
}
# hostname -a is deprecated, do it by ourself
get_alias() {
local ips
local entries
local alias_set
ips=$(hostname -I)
for ip in $ips; do
# in /etc/hosts, alias can come at the 2nd column
if entries=$(grep "$ip" /etc/hosts | awk '{ $1=""; print $0 }'); then
alias_set="$alias_set $entries"
fi
done
echo "$alias_set"
}
is_localhost() {
local hostnames
local shortnames
local aliasname
local nodename=$1
hostnames=$(hostname -A)
shortnames=$(hostname -A -s)
aliasname=$(get_alias)
hostnames="$hostnames $shortnames $aliasname"
for name in ${hostnames}; do
if [[ $name == "$nodename" ]]; then
return 0
fi
done
return 1
}
# retrieves fence_kdump nodes from Pacemaker cluster configuration
get_pcs_fence_kdump_nodes() {
local nodes
pcs cluster sync > /dev/null 2>&1 && pcs cluster cib-upgrade > /dev/null 2>&1
# get cluster nodes from cluster cib, get interface and ip address
nodelist=$(pcs cluster cib | xmllint --xpath "/cib/status/node_state/@uname" -)
# nodelist is formed as 'uname="node1" uname="node2" ... uname="nodeX"'
# we need to convert each to node1, node2 ... nodeX in each iteration
for node in ${nodelist}; do
# convert $node from 'uname="nodeX"' to 'nodeX'
eval "$node"
# shellcheck disable=SC2154 # $uname from dracut
nodename="$uname"
# Skip its own node name
if is_localhost "$nodename"; then
continue
fi
nodes="$nodes $nodename"
done
echo "$nodes"
}
# retrieves fence_kdump args from config file
get_pcs_fence_kdump_args() {
if [[ -f $FENCE_KDUMP_CONFIG_FILE ]]; then
. "$FENCE_KDUMP_CONFIG_FILE"
echo "$FENCE_KDUMP_OPTS"
fi
}
get_generic_fence_kdump_nodes() {
local filtered
local nodes
nodes=$(kdump_get_conf_val "fence_kdump_nodes")
for node in ${nodes}; do
# Skip its own node name
if is_localhost "$node"; then
continue
fi
filtered="$filtered $node"
done
echo "$filtered"
}
# setup fence_kdump in cluster
# setup proper network and install needed files
kdump_configure_fence_kdump() {
local kdump_cfg_file=$1
local nodes
local args
if is_generic_fence_kdump; then
nodes=$(get_generic_fence_kdump_nodes)
elif is_pcs_fence_kdump; then
nodes=$(get_pcs_fence_kdump_nodes)
# set appropriate options in kdump.conf
echo "fence_kdump_nodes $nodes" >> "${kdump_cfg_file}"
args=$(get_pcs_fence_kdump_args)
if [[ -n $args ]]; then
echo "fence_kdump_args $args" >> "${kdump_cfg_file}"
fi
else
# fence_kdump not configured
return 1
fi
# setup network for each node
for node in ${nodes}; do
kdump_collect_netif_usage "$node"
done
dracut_install /etc/hosts
dracut_install /etc/nsswitch.conf
dracut_install "$FENCE_KDUMP_SEND"
}
# Install a random seed used to feed /dev/urandom
# By the time kdump service starts, /dev/uramdom is already fed by systemd
kdump_install_random_seed() {
local poolsize
poolsize=$(< /proc/sys/kernel/random/poolsize)
if [[ ! -d "${initdir}/var/lib/" ]]; then
mkdir -p "${initdir}/var/lib/"
fi
dd if=/dev/urandom of="${initdir}/var/lib/random-seed" \
bs="$poolsize" count=1 2> /dev/null
}
kdump_install_systemd_conf() {
# Kdump turns out to require longer default systemd mount timeout
# than 1st kernel(90s by default), we use default 300s for kdump.
if ! grep -q -r "^[[:space:]]*DefaultTimeoutStartSec=" "${initdir}/etc/systemd/system.conf"*; then
mkdir -p "${initdir}/etc/systemd/system.conf.d"
echo "[Manager]" > "${initdir}/etc/systemd/system.conf.d/kdump.conf"
echo "DefaultTimeoutStartSec=300s" >> "${initdir}/etc/systemd/system.conf.d/kdump.conf"
fi
# Forward logs to console directly, and don't read Kmsg, this avoids
# unneccessary memory consumption and make console output more useful.
# Only do so for non fadump image.
mkdir -p "${initdir}/etc/systemd/journald.conf.d"
{
echo "[Journal]"
echo "Storage=volatile"
echo "ReadKMsg=no"
echo "ForwardToConsole=yes"
} > "${initdir}/etc/systemd/journald.conf.d/kdump.conf"
}
remove_cpu_online_rule() {
local file=${initdir}/usr/lib/udev/rules.d/40-redhat.rules
if [[ -f $file ]]; then
sed -i '/SUBSYSTEM=="cpu"/d' "$file"
fi
}
install() {
declare -A unique_netifs ipv4_usage ipv6_usage