Skip to content

Latest commit

 

History

History
81 lines (77 loc) · 5.56 KB

WorkerListItem.md

File metadata and controls

81 lines (77 loc) · 5.56 KB

WorkerListItem

Properties

Name Type Description Notes
platform \Swagger\Client\Model\Platform [optional]
name string Display name [optional]
description string [optional]
units_count int [optional]
active bool [optional] [default to true]
password string [optional]
tag_ids int[] [optional]
mirror_url \Swagger\Client\Model\MirrorUrl [optional]
red_temp int Red Temperature, °C [optional]
red_mem_temp float Red memory temperature (for rigs), °C [optional]
red_cpu_temp float Red CPU temperature (for rigs), °C [optional]
red_board_temp float Red Board Temperature (for ASICs), °C [optional]
red_fan int Red Fan speed, % [optional]
red_asr int Red Accepted Shares Ratio, % [optional]
red_la float Red Load Average per one CPU core [optional]
red_hashrates object[] Red hashrates per algo [optional]
ip_addresses string[] List of assigned ip addresses [optional]
remote_address object Remote address info [optional]
vpn bool VPN is configured [optional]
has_amd bool Worker has AMD GPUs [optional]
has_nvidia bool Worker has Nvidia GPUs [optional]
needs_upgrade bool New OS version is available [optional]
packages_hash string packages_hash [optional]
lan_config object LAN configuration [optional]
system_type string Hive OS system type [optional]
os_name string [optional]
has_octofan bool Worker has Octominer fan controller [optional]
has_coolbox bool Worker has Coolbox fan controller [optional]
has_fanflap bool Worker has FanFlap controller [optional]
has_powermeter bool Worker has Powermeter controller [optional]
has_asichub bool Worker is an ASIC Hub [optional]
has_donnager_relay bool Worker is a Donnager Relay controller [optional]
personal_settings object Personal settings for current user [optional]
versions object [optional]
stats object Worker stats [optional]
flight_sheet \Swagger\Client\Model\FSMidInfo [optional]
overclock object Actually applied overclock [optional]
tuned_miners \Swagger\Client\Model\MinerName[] List of miner names from active flight sheet that are tuned in this worker. [optional]
miners_summary object [optional]
miners_stats object [optional]
hardware_info object Hardware information [optional]
hardware_stats object Hardware stats [optional]
gpu_summary object GPU summary stats [optional]
gpu_info \Swagger\Client\Model\GpuInfo[] GPU information [optional]
gpu_stats object[] GPU stats [optional]
asic_info object ASIC information [optional]
asichub_id int ID of AsicHUB which manages this ASIC [optional]
asic_stats object ASIC stats [optional]
watchdog object Watchdog system [optional]
options object Worker options. This object will be merged with existing one on update. [optional]
hardware_power_draw int Power consumption of worker's hardware, watts [optional]
psu_efficiency int Efficiency of power supply unit, % [optional]
octofan_correct_power bool Apply power correction settings to power consumption value from Octominer fan controller. Default is false. [optional]
autofan object Autofan configuration [optional]
octofan object Configuration for Octominer fan controller [optional]
octofan_stats object Octominer's fan controller stats [optional]
coolbox object Configuration for Coolbox fan controller [optional]
coolbox_info object Information about installed Ykeda Autofan controller [optional]
coolbox_stats object Coolbox fan controller stats [optional]
fanflap object Configuration for FanFlap controller [optional]
fanflap_stats \Swagger\Client\Model\FanflapStats [optional]
powermeter object Configuration for Powermeter controller [optional]
powermeter_stats \Swagger\Client\Model\PowermeterStats [optional]
donnager_relay object Donnager Relay configuration [optional]
donnager_relay_info object Donnager Relay information [optional]
donnager_relay_stats object Donnager Relay stats [optional]
ykeda_autofan object Configuration for Ykeda Autofan controller [optional]
ykeda_autofan_stats object Ykeda Autofan controller stats [optional]
commands object[] Worker queue commands [optional]
benchmark_id int ID of currently running benchmark. This field is present until the benchmark is finished. [optional]
asic_config map[string,string] Settings for ASICs with Hive firmware, depends on model and firmware version [optional]
messages_counts object [optional]

[Back to Model list] [Back to API list] [Back to README]