diff --git a/src/04-modality-specific-files/01-magnetic-resonance-imaging-data.md b/src/04-modality-specific-files/01-magnetic-resonance-imaging-data.md index 18e52c2096..7d74db3bea 100644 --- a/src/04-modality-specific-files/01-magnetic-resonance-imaging-data.md +++ b/src/04-modality-specific-files/01-magnetic-resonance-imaging-data.md @@ -57,7 +57,7 @@ that a given scan was collected with the intended coil elements selected | **Key name** | **Requirement level** | **Data type** | **Description** | |--------------------------------|-----------------------|---------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | NumberShots | RECOMMENDED | [number][] | The number of RF excitations need to reconstruct a slice or volume. Please mind that this is not the same as Echo Train Length which denotes the number of lines of k-space collected after an excitation. | -| ParallelReductionFactorInPlane | RECOMMENDED | [number][] | The parallel imaging (e.g, GRAPPA) factor. Use the denominator of the fraction of k-space encoded for each slice. For example, 2 means half of k-space is encoded. Corresponds to DICOM Tag 0018, 9069 `Parallel Reduction Factor In-plane`. | +| ParallelReductionFactorInPlane | RECOMMENDED | [number][] | The parallel imaging (for instance, GRAPPA) factor. Use the denominator of the fraction of k-space encoded for each slice. For example, 2 means half of k-space is encoded. Corresponds to DICOM Tag 0018, 9069 `Parallel Reduction Factor In-plane`. | | ParallelAcquisitionTechnique | RECOMMENDED | [string][] | The type of parallel imaging used (for example GRAPPA, SENSE). Corresponds to DICOM Tag 0018, 9078 `Parallel Acquisition Technique`. | | PartialFourier | RECOMMENDED | [number][] | The fraction of partial Fourier information collected. Corresponds to DICOM Tag 0018, 9081 `Partial Fourier`. | | PartialFourierDirection | RECOMMENDED | [string][] | The direction where only partial Fourier information was collected. Corresponds to DICOM Tag 0018, 9036 `Partial Fourier Direction`. | @@ -376,6 +376,14 @@ participant, task and run takes precedence. ## Diffusion imaging data +Diffusion-weighted imaging data acquired for a participant. +Currently supported image types include: + +| **Name** | `suffix` | **Description** | +|---------------------- | -------- | ----------------------------------------------------------------- | +| DWI | dwi | Diffusion-weighted imaging contrast (specialized T2\* weighting). | +| Single-Band Reference | sbref | Single-band reference for one or more multi-band `dwi` images. | + Template: ```Text @@ -389,31 +397,66 @@ sub-